Click here to download ELECTRIQ EAP120HC (01) PDF MANUAL


PDF Content Summary:

****** Page 1 ****** ElectrlQ UK SUPPORT ElectrIQ.co.uk/support Please, for your own convenience, check the troubleshooting guide before calling the service line. If the unit still fails to operate call: 0871 620 1057 or complete the online form Office hours: 9AM – 5PM Monday to Friday ElectriQ.co.uk Unit 2, The Nursery Berristow Lane South Normanton Derbyshire, DE-55 2FX electri(.å USER MANUAL EAP120HC 0006 4 Thank you for choosing electrIQ Please read this user manual before using this innovative Air Purifier and keep it safe for future reference. Visit our page electrIQ.co.uk for our entire range of Intelligent Electricals

****** Page 2 ****** POI Safety Instructions CONTENTS Technical Specification & Troubleshooting Air Purifier Features and Indoor Pollutants Operation Filter Installation Diagram of the Air Purifier Care and Maintenance Technical Specification & Troubleshooting 2-3 4 5-6 7 7 8 9-10 Troubleshooting Issue Not working Air quality indicator is always red Abnormal Smells Pollutants not removed and loud noise when running Disposal Check Check that the power adapter is connected and is the correct rating. Sensor can be influenced by water vapour,fumes and aerosols. Test the unit in another clean environment. Check if the filters clean. Replace filters. Check if the filters clean. Replace filters. Disposal: Do not dispose this product as unsorted waste. Collection of such waste must be handled separately as special treatment is necessary. Recycling facilities are now available for all customers at which you can deposit your old electrical products. Customers will be able to take any old electrical equipment to participating sites run by their local councils. Please remember that this equipment will be further handled during the recycling process, so please be considerate when depositing your equipment. Please contact the local council for details of your local household waste recycling centres.

****** Page 3 ****** P09 Technical Specification & Troubleshooting Safety Instruction Important Carefully read the instructions before operating the unit. • This appliance is for indoor use only. his unit must only be connected to a 220-240V / 50Hz earthed outlet. P02 Technical Specification Model Fan Speed Airflow (m3/hr) Noise level (db) Power rating (W) Ions Power cord length Net Size (wxdxh) Net Weight Voltage Filters Purification Rate voc Odours (tobacco, food, pet smells etc.) Dust, pollen, allergens, mildew Bacteria, Viruses, Germs PM 2.5 Size (wxdxh) Multifunctional Filter Low 30 25 EAP120HC High 55 39 < 8 Watts 5×106 ions/cm3 1.2 meters 19x19x23.8 cm 1.3 kgs 220-240V/ 50 hz AC/DC Adapter 12V , XX Amps All in one filter cartridges x 2 Efficiency 99.9% 99.7% 94.9% Effciency 99.9% Particle Size NA so.00025 mm 10.6 x6.7 x 3.3 cm HEPA Filter layer Particle Size Life Time about I year about I year about I year about I year about 1 year Life Time about I year 9.0003 mm Pre-filter and Carbon Activated Filter layer Material Walnut Shell Active Filter Absorption Surface 300,000 rn2 Catalytic Filter layer Life Time about I year Installation must be in accordance with regulations of the country where the unit is used. • If you are in any doubt about the suitability of your electrical supply, have it checked and, if necessary, modified by a qualified electrician. • This air purifier has been tested and is safe to use. However, as with any electrical appliance use it with care. • Disconnect the air purifier from the socket when changing the filters or cleaning the unit. Avoid touching any moving parts of the appliance. Never insert fingers, pencils or any other objects through the guard. • This device is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities. It is also not intended for use by those with a lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Do not leave children unsupervised with this device. Do not clean the unit by spraying it or immersing it in water. Use a damp cloth only. Never allow water or vapours to enter the unit. Do not clean with strong chemical agents or other abrasive materials. Never connect the unit to an electrical outlet using an extension cord. If a power outlet is not available, one should be installed by a qualified electrician. Never operate this appliance if the cord or power supply are damaged. Ensure the power cord is not stretched or exposed to sharp objects/edges. • A damaged power supply should be replaced by the manufacturer. Never extend or attempt to change the power supply lead. Any service other than regular cleaning or filter replacement should be performed by an authorised service representative. Failure to comply could result in a voided warranty. Do not use the appliance for any other purposes than its intended use. Avoid removing the power cord from the socket whilst the unit is still in operation. This could cause electrical damage. Never use the power supply as a switch to start and turn off the air purifier unit. Use the provided ON/OFF switch located on the control panel. Always place the unit on a dry and stable surface. The use of accessory attachments that have not been approved by the appliance manufacturer is not recommended, as this may result in fire, cause an electric shock and or cause personal injury. Ensure hands are fully dried before plugging or unplugging the appliance. The appliance should not be installed in laundry or wet rooms. ****** Page 4 ****** Safety Instruction P03 Important Energy Saving and Unit Safety Protection Tips • Do not cover or restrict the airflow from the outlet or inlet grills. • For maximum performance and safety the minimum distance from a wall or objects should be 20cm. Keep away from other electrical appliances. • Keep the filters clean. Under normal conditions, filters should only needcleaning once every two weeks (approximately). Since the filters remove airborne particles, more frequent cleaning may be necessary, depending onthe air quality. EAP120HC provides 5 stages of air purification using professional air filtration and intelligent sterilisation technologies. This unit features advanced all in one dual photocatalytic HEPA and activated carbon filter for improved air filtration. toaaoeoe Primary filter, made of non-woven materials, are used for removing large particles like hair and dust. – Antibacterial HEPA filter to remove 99.9% of airborne particles of 0.25 microme tres or larger. – Activated carbon filter removes unpleasant odours and absorbs harmful substances such as formaldehydes and benzenes. Photocatalytic filter with molecular sieve adsorption layer removes smaller particles and decompose further the pollutants. Plasma Ioniser sterilises even further and removes mould spores and allergens from the air. The EAP120HC also features an air quality LED indicator that will help in monitoring the quality of the air. Applications: Personal use in domestic and office space to improve air quality Helps smokers to minimise the effects of smoking Helps asthma and pollen sufferers – Great for children' s rooms and small offices NOTE: This air purifier is not a substitute for proper ventilation, regular vacuum cleaning or for the use of a cooker hood whilst cooking. If the humidity is over 60% Relative Humidity we recommend using a dehumidifier to reduce the humidity. Care and Maintenance P08 Care and Maintenance Always shut off the unit and unplug from the mains before cleaning or performing any maintenance. When the unit is not in use for long periods, it is advisable to remove the plug from the power socket. • Do not use chemical solvents (such as benzene, alcohol or gasoline) as they may cause irreversible damage to the unit. Cleaning the Case • Only use tepid water and a mild detergent on a soft cloth. • Do not use bleach or abrasives. • Do not splash water directly onto the main unit. • Avoid wetting the power connection port, doing so may cause an electric shock and can lead to the insulation deteriorating or unit to rust. Cleaning the Filters and Filter Holding Area • Hoover the filter gently every 2-3 weeks or more often if used in a dustier environment. • Make sure the filter is not damaged during the process and replace if it does become damaged. Wipe the filter holding area with a dry cloth if necessary. Clean the filter Cover and Clean Air Outlet • Use water and a mild detergent. • Do not use bleach or abrasives. • Do not spray water inside the unit. • If the clean air outlet grilles get soiled easily, use a vacuum attachment or soft brush to clean. • If the filter cover is dirty, hoover it. If it is heavily soiled, wash it with warm soapy water and dry thoroughly before reinserting it in the unit. NOTE: Do no assemble the unit and power it on before all the parts are completely dry. Any other maintenance than what is described in this user manual must be only performed by the service centre. ****** Page 5 ****** P07 Diagram of the Air Purifier Air Purifier Features and Indoor Pollutants VOC (Volatile Organic Compound) — VOCs come from motor vehicle exhausts, P 04 Compostie filter Diagram of Air Purifier Outlet Inlet I Elementary filter 2. HEPAfilter 3.Activated carbon filter Filter cover Digital display ooo 4 Sensor Outlet Inlet gasoline vapour, pollutants such as formaldehyde, ammonia and many other common and chemical solvents such as paints and glues, or can be a by-product of mould growth. VOCs cause irritation to the eyes and or nose as well as causing headaches, nausea and even potential damage to the central nervous system. Pressed wood furniture, newly decorated rooms, paint and cleaning solvents are common sources of vocs. Mould / Fungus — these can affect our respiratory system and cause allergic reactions, like a runny nose, eye and throat irritation, headaches, fatigue and aggravation of asthma. Other indoor pollutants include — bacteria, viruses, dust mites and pollen, etc. Emissions from electronic office equipment — Many studies, including those from EPA and the University of California Berkley, have reported that emissions from office equipment like, computers and printers, include VOCs, ultra-fine particles and ozone. These emissions have been proven to have a negative effect on the health of many people which can be reduced busing an air purifier. Using HEPA filters, Activated Carbon filters and Plasma Ionisation — An effective HEPA filter is absolutely necessary to remove particles, even at a microscopic level; it ensures that the particles are not spread. Plasma Ionisers will sterilise the air and reduce bacterial growth. The antibacterial activated carbon on the EAP120HC is a natural material biosynthesized from walnut shell, the adsorption area of activated caron is very large up to 300,000 square meters. The activated carbon filter will absorb unpleasant odours and reduce the VOC content in the air. The Plasma Ioniser will sterilise the air and reduce bacterial growth. ****** Page 6 ****** P05 Before first use Operation Operation 4) Remove the plug adapter and How to Use: P06 1) Unpack the appliance and remove the filter cover: ON/OFF 00000 IONISER TIMER 4 AIR 4H 8H TIMER SPEEO 2) Remove the filter and plastic bag: 3) Load 2 composite filters and close the cover: connect it to the DC socket on the bottom: 5) Connect the plug to an earthed socket: 1 Press the ON/OFF button to turn the unit on. Press again to turn off. Pressing the Ioniser button will activate the ioniser function. Press again to turn off. With the unit powered on, press the TIMER button to select the automatic off time. Press repeatedly to select 2, 4 or 8 hours. With the unit powered off, press the TIMER button to select the automatic start time. Press repeatedly to select 2, 4 or 8 hours. Alter the fan speed by pressing the SPEED button. Select from Medium or High. The AIR QUALITY indicator will be illuminated blue if air quality is good. It will be red if the air quality is poor. Changing the Filter Open the filter cover by pressing in the retaining tabs and pulling the cover free. Remove the old filters by simply pulling on the tabs to release then. Replace the filters with new/clean ones and replace the filter cover.

FREE ENGLISH PDF

OPERATING INSTRUCTIONS

USER GUIDE – USER MANUAL

OWNER GUIDE – OWNER MANUAL

REFERENCE GUIDE – REFERENCE MANUAL

INSTRUCTION GUIDE – INSTRUCTION MANUAL



ELECTRIQ EAP120HC (01) PDF MANUAL

Leave a comment, question, review or page error below. Account not required.

This site uses Akismet to reduce spam. Learn how your comment data is processed.