****** Page 2 ****** elationlighting.com 02014 ELATION PROFESSIONAL all rights reserved. Information, specifications, diagrams, images, and instructions herein are subject to change without notice. ELATION PROFESSIONAL logo and identifying product names and numbers herein are trademarks of ELATION PROFESSIONAL, Copyright protection claimed includes all forms and matters of copyrightable materials and information now allowed by statutory or judicial law or hereinafter granted. Product names used in this document may be trademarks or registered trademarks of their respective companies and are hereby acknowledged, All non-ELATION brands and product names are trademarks or registered trademarks of their respective companies, ELATION PROFESSIONAL and all affiliated companies hereby disclaim any and all liabilities for property, equipment, building, and electrical damages, injuries to any persons, and direct or indirect economic loss associated with the use or reliance of any information contained within this document, and/or as a result of the improper, unsafe, insufficient and negligent assembly, installation, rigging, and operation of this product, Elation Professional USA | 6122 S, Eastern Ave, I Los Angeles, CA. 90040 323-582-3322 | 323-832-9142 fax I elationlighting.com I Elation Professional B.V, I Junostraat2 | 6468 EW Kerkrade, Netherlands +31 45 546 85 66 | +31 45 546 85 96 fax I elationlighting.eu I DOCUMENT VERSION Please check elationlighting.com for the latest revision/update of this manual. Date 3/30/2015 Document Version 3 Software Version DMX Channel Modes 14/ 16/ 18/20 2 Notes Added Speed Modes (Standard, High), cETLus Approval. SNIPER 2RTM User Manual ver 3

****** Page 3 ****** elationlighting.com General Information Warranty Safety Instructions General Guidelines Discharge Lamp Warning Fixture Overview Lamp Installation Instructions Fixture Installation Understanding DMX Fixture Menu DMX Channel Functions And Values Cleaning and Maintenance Technical Specifications Optional Accessories 3 4 6 7 8 9 10 20 23 27 30 35 36 38 SNIPER 2RTM User Manual ver 3

****** Page 4 ****** elationlighting.com INTRODUCTION Congratulations, you have just purchased one of the most innovative and revolutionary new hybrid lighting fixtures on the market today! The SNIPER 2RTM has been designed to perform reliably for years when the guidelines in this booklet are followed. Please read and understand the instructions in this manual carefully and thoroughly before attempting to operate this unit. These instructions contain important information regarding safety during use and maintenance, UNPACKING Thank you for purchasing the SNIPER 2RTM by Elation Professional@ Every SNIPER 2RTM has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during shipping. If the carton appears to be damaged, carefully inspect your unit for damage and be sure all accessories necessary to operate the unit have arrived intact, In the event damage has been found or parts are missing, please contact our customer support team for further instructions. Please do not return this unit to your dealer without first contacting customer support at the number listed below, Please do not discard the shipping carton in the trash, Please recycle whenever possible. BOX CONTENTS (l) powerCON Cable Manual & Warranty Card 4 SNIPER 2RTM User Manual ver 3

****** Page 5 ****** elationlighting.com CUSTOMER SUPPORT Elation Professional@ provides a customer support line, to provide set up help and to answer any question should you encounter problems during your set up or initial operation. You may also visit us on the web at elationlighting.com for any comments or suggestions, For service related issue please contact Elation Professional@, ELATION SERVICE USA – Monday – Friday 8:OOam to 5:OOpm PST Voice: 323-582-3322 Fax: 323-832-9142 E-mail: support@elationlighting.com ELATION SERVICE EUROPE – Monday – Friday 08:30 to 17:00 CET Voice: +31 45 546 85 30 Fax: +31 45 546 85 96 E-mail: support@elationlighting.eu WARRANTY REGISTRATION The SNIPER 2RTM carries a two-year (730 days) limited warranty. Please fill out the enclosed warranty card to validate your purchase, All returned service items whether under warranty or not, must be freight pre-paid and accompany a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package. A brief description of the problem as well as the RIA, number must also be written down on a piece of paper and included in the shipping container. If the unit is under warranty, you must provide a copy of your proof of purchase invoice, Items returned without a R.A. number clearly marked on the outside of the package will be refused and returned at customer’s expense. You may obtain a R.A. number by contacting customer support at 323-582-3322. IMPORTANT NOTICE! There are no user serviceable parts inside this unit. Do not attempt any repairs yourself; doing so will void your manufactures warranty. Damages resulting from modifications to this fixture and/or the disregard of safety and general user instructions found in this user manual void the manufactures warranty and are not subject to any warranty claims and/or repairs. 5 SNIPER 2RTM User Manual ver 3

****** Page 6 ******

elation lighting. com A, Elation Professional@ hereby warrants, to the original purchaser, Elation Professional@ products to be free of manufacturing defects in material and workmanship for a period of two years (730 days), and Elation Professional@ product rechargeable batteries to be free of manufacturing defects in material and workmanship for a period of six months (1 80 days), from the original date of purchase, This warranty excludes discharge lamps and all product accessories. This warranty shall be valid only if the product is purchased within the United States of America, including possessions and territories, It is the owner’s responsibility to establish the date and place of purchase by acceptable evidence, at the time service is sought, B. For warranty service, send the product only to the Elation Professional@ factory, All shipping charges must be pre-paid, If the requested repairs or service (including parts replacement) are within the terms of this warranty, Elation Professional@ will pay return shipping charges only to a designated point within the United States, If any product is sent, it must be shipped in its original package and packaging materiali No accessories should be shipped with the product. If any accessories are shipped with the product, Elation Professional@ shall have no liability what so ever for loss and/or or damage to any such accessories, nor for the safe return thereof. C, This warranty is void if the product serial number and/or labels are altered or removed; if the product is modified in any manner which Elation Professional@ concludes, after inspection, affects the reliability of the product; if the product has been repaired or serviced by anyone other than the Elation Professional@ factory unless prior written authorization was issued to purchaser by Elation Professional@; if the product is damaged because not properly maintained as set forth in the product Instructions, guidelines and/or user manuali D, This is not a service contract, and this warranty does not include any maintenance, cleaning or periodic check-up. During the periods as specified above, Elation Professional@ will replace defective parts at its expense, and will absorb all expenses for warranty service and repair labor by reason of defects in material or workmanship. The sole responsibility of Elation Professional@ under this warranty shall be limited to the repair of the product, or replacement thereof, including parts, at the sole discretion of Elation Professional@. All products covered by this warranty were manufactured after January 1, 1990, and bare identifying marks to that effect, E. Elation Professional@ reserves the right to make changes In design and/or performance improvements upon its products without any obligation to include these changes in any products theretofore manufactured. F, No warranty, whether expressed or implied, is given or made with respect to any accessory supplied with the products described above. Except to the extent prohibited by applicable law, all implied warranties made by Elation Professional@ in connection with this product, including warranties of merchantability or fitness, are limited in duration to the warranty periods set forth above, And no warranties, whether expressed or implied, including warranties of merchantability or fitness, shall apply to this product after said periods have expired. The consumer’s and/or dealer’s sole remedy shall be such repair or replacement as is expressly provided above; and under no circumstances shall Elation Professional@ be liable for any loss and/or damage, direct and/or consequential, arising out of the use of, and/or the inability to use, this product. G. This warranty is the only written warranty applicable to Elation Professional@ products and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published 6 SNIPER 2RTM User Manual ver 3

****** Page 7 ****** elation lighting. SAFETY

INSTRUCTIONS com The SNIPER 2RTM is an extremely sophisticated piece of electronic equipment, To guarantee a smooth operation, it is important to follow the guidelines in this manual. The manufacturer of this device will not accept responsibility for damages resulting from the misuse of this fixture due to the disregard of the information printed in this manual, This device falls under PROTECTION CLASS 1, It’s essential this device be grounded properly, Only qualified personnel should perform all electrical connections, A U I o N s KEEP THIS FIXTURE AWAY FROM RAIN AND MOISTURE! UNPLUG POWER BEFORE SERVICING FIXTURE! NEVER TOUCH FIXTURE DURING OPERATION, IT MAY BE HOT! NEVER LOOK DIRECTLY INTO THE LIGHT SOURCE! SENSITIVE PERSONS MAY SUFFER AN EPILETIC SHOCK! For proper operation, follow the Installation guidelines described in this manual, Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts (brackets) included with this fixture should be used for installation, Any modifications will void the original manufactures warranty and increase the risk of damage and/or personal injury, Never look directly into the light source of this fixture to prevent risk of injury to your retina, which may induce blindness, Those suffering from directly into the light source of this unit at all times, should avoid looking The fan and air inlets must remain clean and never blocked, Allow approx. 6″ (15cm) between this fixture and other devices or a wall for proper cooling, Always disconnect from main power source before performing any type of service and/or cleaning procedure, Only handle the power cord by the plug end, never pull out the plug by tugging the wire portion of the cord, Do not operate this fixture if the power cord has become frayed, crimped and/or damaged, If the power cord is damaged, replace it immediately with a new one of similar power rating, 7 SNIPER 2RTM User Manual ver 3

****** Page 8 ****** elationlighting.com NEVER OPEN THIS FIXTURE WHILE IN USE! During the initial operation of this fixture, a light smoke or smell may emit from the interior of the fixture. This is a normal process and is caused by excess paint in the interior of the casing burning off from the heat associated with the lamp and will decrease gradually over time. This fixture is a professional lighting effect designed for INDOOR / DRY LOCATIONS ONLY on stage, in nightclubs, theatres, etc. Please make sure there are NO FLAMMABLE MATERIALS close to the fixture while operating, to prevent any fire hazard, Minimum distance to lighted objects must be 16.4 feet (5m), Maximum temp of the external surface 1940F (900C) Minimum distance of inflammable materials from the surface 1.6 feet (0.5m) The fixture must be installed in a location with adequate ventilation, at least 1 15 feet (.5m) from adjacent surfaces. Be sure no air ventilation slots are blocked. DO NOT attempt installation and/or operation without knowledge how to do so. DO NOT allow operation by persons who are not qualified to operate this type of fixture, Most damages are the result of operations by nonprofessionals. Consistent operational breaks may ensure the fixture will function properly for many years to come. DO NOT shake fixture, avoid brute force when installing and/or operating fixture, Always install the fixture with an appropriate safety cable, When installing the fixture in a suspended environment, always use mounting hardware that is no less than MIO x 25 mm, also be sure the hardware is insert in the pre-arranged screw holes in the bracket of the fixture. Use the original packaging and materials to transport the fixture in for service. DO NOT TOUCH the housing bare-hand during its operation. Turn OFF the power and allow approximately 15 minutes for the fixture to cool down before replacing or serving, 8 SNIPER 2RTM User Manual ver 3

****** Page 9 ****** elationlighting.com This fixture is fitted with a DISCHARGE LAMP, which is highly susceptible to damage if improperly handled. NEVER touch the lamp with your bare hands, as the oil from your hands will shorten the life of the lamp. Also, NEVER move the fixture until the lamp has had ample time to cool. Lamps are NOT covered under warranty conditions. Avoid switching the fixture ON and OFF repeatedly in short intervals, as this will reduce lamp life and intensity. To achieve the intensity associated with discharge lamps, these lamps use gas sealed in a high-pressure environment to emit a brilliant output. Due to the high pressure involved with the construction of the lamp, the lamp MAY EXPLODE DURING PROLONGED EXTENSIVE USE. This risk is increased with age; added care is encouraged when dealing with older lamps. Thus, the lamp must always be replaced at the end of their recommended duty cycle. Extreme caution should be used when operating this or any fixture fitted with a gas discharge lamp. UV RADIATION NOTICE This fixture emits intense UV radiation, which is harmful to the eyes and skin. The intense luminance of the lamp can cause severe damage to the retina. NEVER operate this fixture with ANY of the protective covers removed. These covers have been specially designed to shield against UV radiation. LAMP REPLACEMENT Please note that due to the nature of the PhillipsTM Platinum 2R Lamp and the optical path of the Elation SNIPER 2RTM fixture, the lamp MUST BE replaced at 6,000 hours. Use only Genuine Original PhillipsTM platinum lamps. Other brand lamps may cause damage and void warranty! 9 SNIPER 2RTM User Manual ver 3

****** Page 10 ****** elationlighting.com 2 8 9 7 6 oooo 4 5 3 10 1. 2. 3. 4. 5. 6. 7. Adjustable Mounting Yoke LCD Menu Function Display MENU, DOWN, UP, ENTER Buttons Safety Cable Attachment Hook FUSE powerCON IN/OUT 5Pin DMX IN/OUT Lamp Cover Plate SNIPER 2RTM User Manual ver 3

****** Page 11 ****** LAMP elationlighting.com INSTALLATION INSTRUCTIONS LAMP REPLACEMENT Please note that due to the nature of the PhillipsTM Platinum 2R Lamp and the optical path of the Elation SNIPER 2R fixture, the lamp MUST BE replaced at 6,000 hours. Use only Genuine Original PhillipsTM Platinum 2R Lamps. Other brand lamps may cause damage and void warranty! INSTALLING OR REPLACING THE LAMP To ensure a proper/safe lamp change, carefully read all the following instructions. LAMP SAFETY INSTRUCTIONS • ALWAYS replace lamp after 6,000 Hours. Use only Genuine Original PhillipsTM Platinum 2R lamps. Other brand lamps may cause damage and void the warranty! NEVER touch the lamp with your bare hands, as the oil from your hands will shorten the life of the lamp. Always disconnect the fixture’s main power supply before replacing lamp. Allow fixture to cool for at least 15 minutes before attempting any type of service. Make sure ALL covers/panels are replaced/secured before operating the fixture to prevent any risk and/or damage to eye retina from UV Radiation exposure! SNIPER 2RTM User Manual ver 3

****** Page 12 ****** elationlighting. com LAMP INSTALLATION PROCEDURE 1. Remove (2) screws on lamp cover plate as indicated below. ooo ooo SNIPER 2RTM User Manual ver 3

****** Page 13 ****** elationlighting.com LAMP INSTALLATION PROCEDURE – continued 2. Remove lamp cover plate to access the lamp. 3. Gently remove (2) Wires connected to spade terminals on base of lamp. 13 00 D D SNIPER 2RTM User Manual ver 3

****** Page 14 ****** elationlighting.com LAMP INSTALLATION PROCEDURE – continued 5. Using your thumb, gently push the base of the lamp towards the RIGHT to release, oono tö)td Once lamp is released/ grab the lamp base with your thumb and index finger and gently pull the lamp OUT towards the LEFT and AWAY from the fixture, 14 SNIPER 2RTM User Manual ver 3

****** Page 15 ****** com LAMP INSTALLATION PROCEDURE – elationlighting. continued 6. Using a clean cloth or gloves, gently install the new lamp into the fixture using your thumb and index finger, making sure the spade terminals on the base of the lamp are facing towards the LEFT, 15 SNIPER 2RTM User Manual ver 3

****** Page 16 ****** elationlighting. com LAMP INSTALLATION PROCEDURE – continued 7. 8. Seat the RIGHT edge of the lamp under the (2) retention clips first, then using your thumb, gently push the lamp base towards the RIGHT and DOWN until the lamp locks into place, Make sure the lamp is properly seated into place just like the old lamp was. SNIPER 2RTM User Manual ver 3

****** Page 17 ****** elationlighting. LAMP INSTALLATION PROCEDURE – continued 9. Gently attach the (2) Wires to spade terminals on the base of the lamp, 10. Make sure each wire is securely attached to the lamp, com SNIPER 2RTM User Manual ver 3

****** Page 18 ******

elation lighting. com LAMP INSTALLATION PROCEDURE – continued 11. Replace the lamp cover plate back into place by securing the (2) screws. ooo ooo 12. Power fixture ON and make sure the lamp strikes ON 18 SNIPER 2RTM User Manual ver 3

****** Page 19 ****** elationlighting.com LAMP HOURS RESET PROCEDURE 2 3. 4. Access the main menu by pressing the MENU button and then pressing the UP or DOWN buttons until “LAMP RESET TIME” is displayed. Press the ENTER button and then press the UP or DOWN to until “YES” is displayed, Press the ENTER button to select “YES”, The lamp timer has now been reset, Press the MENU button to exit and return to the home screen, LAMP OPTIMIZATION Unlike traditional discharge lamps the PhillipsTM Platinum 2R Lamp does NOT require optimization. The lamp orientation and optimization procedure has been preset during the manufacturing process of the lamp. Please remember the PhillipsTM Platinum 2R Lamp is NOT a hot-restrike lamp therefore, therefore you must wait approximately 15 minutes before you can attempt to restrike the lamp once it has been turned off. SNIPER 2RTM User Manual ver 3

****** Page 20 ****** FIXTURE elationlighting.com INSTALLATION FLAMMABLE MATERIAL WARNING Keep fixture at least 5.0 ft. (1.5m) away from any flammable materials, decorations, pyrotechnics, etc. A qualified electrician should be used for all electrical connections and/or installations. CAUTIONS For added protection, mount the fixture in areas outside walking paths, seating areas, or in areas were unauthorized personnel might reach the fixture, Max ambient operating temperature for this fixture is 1040F. (400C) Do not use the fixture under or above this temperature. Before mounting the fixture to any surface, make sure the installation area can hold a minimum point load of 10 times the weight of the fixture. Fixture installation must always be secured with a secondary safety attachment, such as an appropriate safety cable. Never stand directly below the device when mounting, removing or servicing, POWER LINKING Max number of units that can be power linked is 7 units @120V / 14 units @230V. w R N N G MINIMUM distance to lighted objects must be 16.5 feet (5m) MAXIMUM temperature of extemal surface 1940 F (900 C) MINIMUM distance of inflammable mateials from sufface 1.6 feet (0.5m) Keep fixwre at least 5.0 feet (1.5m) away from any flammable materials, decorations, pyrotechnics, etc. 20 SNIPER 2RTM User Manual ver 3

****** Page 21 ****** elationlighting. com MOUNTING POINTS Overhead mounting requires extensive experience, including amongst others calculating working load limits, installation material being used, and periodic safety inspection of all installation material and the device. If you lack these qualifications, do not attempt the installation yourself. Improper installation can result in bodily injury, Fixture is fully operational in the specific mounting positions as illustrated below. 0 ETY CABLE Always use a Safety Cable whenever installing this fixture in a suspended environment to ensure the fixture will not drop if the clamp fails. 21 SNIPER 2RTM User Manual ver 3

****** Page 22 ****** elationlighting.com CLAMP MOUNTING The SNIPER 2RTMincludes an adjustable mounting yoke that attaches to both sides of the fixture. When mounting this fixture to truss be sure to secure an appropriately rated clamp to the mounting yoke using a MIO screw fitted through the center hole of the mounting yoke, Be sure to attach a Safety Cable to the fixture using the safety cable rigging point on the back panel. SECURING Regardless of the rigging option you choose for your SNIPER 2RTM always be sure to secure your fixture with a safety cable. The fixture provides a built-in rigging point for a safety cable on the back of the fixture as illustrated below, Be sure to only use the designated rigging point for the safety cable, ooo 22 0000 SNIPER 2RTM User Manual ver 3

****** Page 23 ****** elationlighting.com DMX-512 DMX is short for Digital Multiplex. This is a universal protocol used by most lighting and controller manufactures as a form of communication between intelligent fixtures and controllers. DMX allows all makes and models of different manufactures to be linked together and operate from a single controller. This is possible as long as all the fixtures and the controller are DMX compliant. A DMX controller sends the DMX data instructions to the fixture allowing the user to control the different aspects of an intelligent light. DMX data is sent out as serial data that travels from fixture to fixture via data “IN” and data “OUT” XLR terminals located on the fixtures (most controllers will only have output jacks). DMX LINKING To ensure proper DMX data transmission, always use proper DMX cables and a terminator, When using several DMX fixtures try to use the shortest cable path possible, Never split a DMX line with a “Y” style connector, The order in which the fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned a starting DMX address of 1 may be placed anywhere in the DMX chain, at the beginning, at the end, or anywhere in the middle. The DMX controller knows to send data assigned to address 1 to that fixture no matter where it is located in the DMX chain. The SNIPER 2RTM can be controlled via DMX-512 protocol and the DMX address is set via the control menu. DATA CABLE (DMX Cable) REQUIREMENTS (For DMX and Master/Slave Operation) Your fixture and your DMX controller require a standard 3pin or 5pin XLR connector for data input and data output (see figure below), If you are making your own cables, be sure to use two conductor, shielded digital DMX cable rated at 1 20 ohms; this cable is designed for DMX transmission and may be purchased from your Elation dealer or at most professional lighting retailers. Your cables should be made with a male and female XLR connector on either end of the cable. Also, remember that a DMX line must be daisy chained and cannot be split, unless using an approved DMX splitter such as Elation’s Opto Branch 4TM, Opto Branch 8TM, or DMX-Branch/4TM. 23 SNIPER 2RTM User Manual ver 3

****** Page 24 ****** elationlighting. com DMX Output 3-Pin XLR Socket DMX Input 3-Pifi XLR Socket DMX Output 5-Pin XLR Socket DMX Input 5-Pin XLR Socket 1 ; Ground 2: Data Data 4: Open 5: Open Be sure to follow the above figure when making your own cables, Do not use the ground lug on the XL R connector. Do not connect the cable’s shield conductor to the ground lug or allow the shield conductor to come in contact with the XL R outer casing, Grounding the shield could cause a short circuit and erratic behavior, DMX-512 CONTROLLER CONNECTION Connect the provided XLR cable to the female XLR output of your controller and the other side to the male XLR input of the SNIPER 2RTM. The diagram below illustrates a typical DMX-512 connection when the fixture is in the 20 Channel Mode. You can chain multiple panels together through serial linking. The cable that should be used is two conductor, shielded DMX cable with XLR input and output connectors, Always be sure daisy chain your in and out data connections, never split or “Y” your DMX connections unless you are using an approved DMX splitter such as Elation’s Opto Branch ATM, opto Branch 8TM, or DMX-Branch/4TM DMX CONTROLLER Address 1 Address 21 Address 41 Address 61 DMX-512 CONNECTION WITH DMX TERMINATOR A DMX terminator should be used in all DMX lines especially in longer runs, The use of a terminator may avoid erratic behavior in your DMX line, A terminator is a 120 ohm 1/4 watt resistor that is connected between pins 2 and 3 of a male XLR connector (DATA + and DATA This fixture is inserted in the female XLR connector of the last fixture in your daisy chain to terminate the line, Using a line terminator will decrease the possibilities of erratic behavior, SNIPER 2RTM User Manual ver 3

****** Page 25 ****** elationlighting.com Termination reduces signal errors and avoids signal transmission problems and interference. It is always advisable to connect a DMX terminal, (Resistance 120 Ohm 1/4 W) between PIN 2 (DMX-) and PIN 3 (DMX 4) of the last fixture. 5pin XLR DMX CONNECTORS Some manufactures use 5pin XLR connectors for DATA transmission in place of 3pin. 5pin XLR fixtures may be implemented in a 3pin XLR DMX line. When inserting standard 5pin XLR connectors in to a 3pin line a cable adaptor must be used, these adaptors are readily available at most electric stores. The following chart details a proper cable conversion. a-Pin XLR to 5-Pin XLR Conversion Conductor Ground/Shield Data Compliment signal) Data True (+ signal) Not Used Not Used 3-Pin XLR Female (Out) 5-Pin XLR Male (In) Pin 1 Pin 2 Pin 3 25 Pin Pin 2 Pin 3 Pin 4- Do Not Use Pin 5- Do Not Use I I SNIPER 2RTM User Manual ver 3

****** Page 26 ****** elationlighting.com DMX ADDRESSING All fixtures should be given a DMX starting address when using a DMX controller, so the correct fixture responds to the correct control signal, This digital starting address is the channel number from which the fixture starts to “listen” to the digital control information sent out from the DMX controller, The allocation of this starting DMX address is achieved by setting the correct DMX address on the digital display located on the back of the fixture, You can set the same starting address for all fixtures or a group of fixtures, or set different address for each individual fixture, Be advised that setting all fixtures to the same DMX address will subsequently control all fixtures in the same fashion, in other words, changing the settings of one channel will affect all the fixtures simultaneously, If you set each fixture to a different DMX address, each unit will start to “listen” to the channel number you have set, based on the quantity of control channels (DMX channels) of each fixture. That means changing the settings of one channel will only affect the selected fixture. In the case of the SNIPER 2RTM, when in the 20 Channel Mode you should set the starting DMX address of the first unit to 1, the second unit to 21 (1 + 20), the third unit to 41 (21 + 20), the forth unit to 61 (41 + 20), and so on. Note: During start-up the SNIPER 2RTM will automatically detect whether a DMX data signal is being received or not. If your fixture is connected to a DMX controller and it is not receiving a DMX signal, please check the following: The 5pin XLR input plug (cable with DMX signal from controller) is not connected or is not inserted completely into the DMX input jack of the fixture, The DMX controller is switched off or defective. The DMX cable or connector is defective. A DMX terminator has been inserted into the last fixture in your DMX chain. 26 SNIPER 2RTM User Manual ver 3

****** Page 27 ****** elationlighting.com ON-BOARD SYSTEM MENU The SNIPER 2RTM comes with an easy to navigate system menu. The next section will detail the functions of each command in the system menu, LCD MENU CONTROL PANEL The control panel (see image below) located on back of the fixture allows you to access the main menu and make all necessary adjustments to the SNIPER 2RTM. During normal operation, pressing MENU button once will access the fixture’s main menu. Once in the main menu you can navigate through the different functions and access the sub-menus with the UP and DOWN buttons. Once you reach a field that requires adjusting, press the ENTER button to activate that field and use the UP and DOWN buttons to adjust the field. Pressing the ENTER button once more will confirm your setting. You may exit the main menu at any time without making any adjustments by pressing and holding the MENU button for 3 seconds, ELATION SNIPER MENU O O 27 O ENTER O SNIPER 2RTM User Manual ver 3

****** Page 28 ******

ELATIONO SNIPER 2RTM elation lighting. com MAIN MENU – VERSION 3 Specifications are subject to change without any prior written notice, MENU OPTIONS / VALUES DMX Address (512) Channel Mode 14 chan:, 16 chan:, 18 chan: DMX State Blackout, Last State Back Light Off, On Pan Invert Normal, Invert Tilt Invert Normal, Invert Auto Test on, Off Speed Mode Standard, High Lamp On/Off On, Off Lamp Power On on, Off Lamp Off Via DMX on, Off Lamp On Via DMX on, Off Lamp Off if DMX Off On, Off Lamp Delay os – 255s Lamp Time Reset Lamp Time Fixture Time Firmware Version Defaults Yes, No Reset SPEED MODE 20 chan: DESCRIPTION Set DMX Address Set DMX Channel Mode Set How Fixture Reacts to Loss of DMX Signal or Power Turn LCD Display Back Light On/Off Invert (flip) PAN Control 1 800 Invert (flip) TILT Control 1 800 Run Self-Test Using Internal Programs Set Speed Mode (see note below for more details) Turn Lamp On/Off Set Lamp State While Power is On Turn Lamp Off Via External DMX Controller Turn Lamp On Via External DMX Controller Lamp Turns Off When DMX Signal is Lost Set Delay Time Befiveen Power On and Lamp On Displays Total Lamp Usage Time Resets the Total Lamp Run Time Displays Total Fixture Run Time Displays Software Version of Fixture Return All Settings Back to Factory Default Reset All Motors The fixture movement speed can be set to STANDARD (default) or HIGH, STANDARD mode is recommended for overall effect usage. HIGH mode is recommended for aerial laser-like effect usage. 28 SNIPER 2RTM User Manual ver 3

****** Page 29 ****** elationlighting.com OFFSET ADJUSTMENTS – Calibration ONLY QUALIFIED TECHNICIANS SHOULD PERFORM THESE FUNCTIONS. This function allows small adjustments to be made to the PAN and TILT home positions, the ECCENTRIC drive, the COLOR and GOBO wheels, the SHUTTER, PRISM and PRISM ROTATION effects, to compensate for ware and/or in the event a sensor has been knocked slightly out of place, To access the OFFSET ADJUSTMENTS MENU press and release the MENU button and immediately press and hold the ENTER button for at least 5 seconds, The fixture will now be in the OFFSET ADJUSTMENTS MENU where you can make adjustments to the functions listed below. To exit the OFFSET ADJUSTMENTS MENU press and hold the MENU button for at least 3 seconds, until the display shows ELATION SNIPER. SHUTTER AND BEAM POSITION AFTER EXITING OFFSET ADJUSTMENTS MENU The SHUTTER and BEAM POSITION after exiting the OFFSET ADJUSTMENT MENU will depend on the DMX STATE setting (“Blackou#’ or “Last State”) and/or if the fixture is receiving a DMX signal. ELATIONO SNIPER 2RTM OFFSET ADJUSTMENTS MENU-VERSION 3 Specifications are subject to change without any prior written notice. MENU Pan Offset Tilt Offset Eccentri Color Offset Gobo Offset Shutter Offset Rprism Offset Prism Offset OPTIONS / VALUES (0) (255) (0) – (255) (-127) -(127) (-127) -(127) (-127) -(127) (0) – (255) (-127) – (127) (-127) – (127) 29 DESCRIPTION Adjustment The PAN Home Position Adjustment The TILT Home Position Adjustment of the Eccentric Drive Adjustment of the Color Wheel Adjustment of the Gobo Wheel Adjustment of the Shutter Adjustment of the Prism Rotation Adjustment of the Prism SNIPER 2RTM User Manual ver 3

****** Page 30 ******

CHANNEL FUNCTIONS ELATIONO SNIPER 2RTM iiii-••- elationlighting@com AND VALUES DMX MODE / CHANNEL DMX Channel Values / Functions Version 3 (20 DMX Channels) Specifications are subject to change without any prior written notice, *Rotation direction of effects depends on the orientation of the fixture head. VALUE 0-255 0-255 0-127 128-255 0-255 FUNCTION 2 3 3 4 5 3 4 5 6 3 4 0-255 5 0-255 6 0-255 0-2 3-4 5-6 7-8 9-1 1 12-13 1 a-15 16-17 18-20 m -22 23-24 25-26 27-29 30-31 32-33 34-35 36-38 39-40 1-42 43-44 45-47 50-51 PAN PAN Movement PAN Shaking Movement SLOW to FAST PAN PAN Movement PAN FINE [16 BIT] PAN Movement FINE 6bitl TILT TILT Movement TILT Shaking Movement SLOW to FAST TILT TILT Movement TILT FINE [16 BIT] TILT Movement FINE PAN SHAKING MOVEMENT SPEED PAN Shaking Movement SLOW to FAST TILT SHAKING MOVEMENT SPEED TILT Shaking Movement SLOW to FAST COLORS WHITE spilt WHITE / LIGHT RED LIGHT RED split LIGHT RED / BLUE BLUE split BLUE / GREEN GREEN split GREEN / YELLOW YELLOW split YELLOW / ORANGE ORANGE split ORANGE / MAGENTA MAGENTA split MAGENTA/ LAVENDAR LAVENDAR split LAVENDAR / LIGHT PINK LIGHT PINK split LIGHT PINK / YELLOW-GREEN YELLOW GREEN split YELLOWGREC-N / PEACOCK BLUE PEACOCK BLUE split PEACOCK BLUE / MEDIUM PINK MEDIUM PINK 30 SNIPER 2RTM User Manual ver 3

****** Page 31 ******

ELATION@ SNIPER 2RTM elation lighting. com DMX Channel Values / Functions Version 3 (20 DMX Channels) Specifications are subject to change without any prior written notice. *Rotation direction of effects depends on the orientation of the fixture head. MODE / CHANNEL 105-112 113-119 120-126 127-133 134-194 VALUE 52-53 54-56 57-58 59-60 61-62 63-65 66-67 68-128 129-190 191-193 194-255 0-7 8-14 15-22 23-29 30-37 38-44 45-52 53-59 60-67 68-74 75-82 83-89 90-97 98-104 195-255 FUNCTION 14 3 4 16 5 6 18 7 8 20 8 COLORS [continued] split MEDIUM PINK / MEDIUM PURPLE MEDIUM PURPLE split MEDIUM PURPLE / PINEAPPLE YELLOW PINEAPPLE YELLOW split PINEAPPLE YELLOW / CONGO BLUE CONGO BLUE WHITE Color Wheel Index – WHITE to CONGO BLUE *Clockwise Color Rotation from FAST to SLOW STOP *Counterclockwise Color Rotation from SLOW to FAST GOBOS OPEN Gobo I Gobo 2 Gobo 3 Gobo 4 Gobo 5 Gobo 6 Gobo 7 Gobo 8 Gobo 9 Gobo 10 Gobo Gobo 12 Gobo 1 3 Gobo 4 Gobo 5 Gobo 16 Gobo 1 7 *Clockwise Gobo Wheel Rotation From FAST to SLOW *Counterclockwise Gobo Wheel Rotation From SLOW to FAST 31 SNIPER 2RTM User Manual ver 3

****** Page 32 ******

ELATION@ SNIPER 2RTM elation lighting. com DMX Channel Values / Functions Version 3 (20 DMX Channels) Specifications are subject to change without any prior written notice. *Rotation direction of effects depends on the orientation of the fixture head. MODE / CHANNEL VALUE 34-42 43-50 51 59 60 68-76 102-110 111-118 119-127 128-135 145-152 153-161 162-169 170-178 179-186 187-195 FUNCTION 14 5 6 7 16 8 9 18 9 10 11 20 9 10 11 0-8 9-16 17-25 26-33 85-93 94-101 136 -144 196-203 204-212 213-220 221-229 230-237 238-246 247-255 0-9 10-120 126-141 142-245 246-255 0-9 10-120 121-134 135-245 246-255 PATTERN MACROS OFF Pattern Macro I Pattern Macro 2 Pattern Macro 3 Pattern Macro 4 Pattern Macro 5 Pattern Macro 6 Pattern Macro 7 Pattern Macro 8 Pattern Macro 9 Pattern Macro 10 Pattern Macro 11 Pattern Macro 12 Pattern Macro 13 Pattern Macro 1 Pattern Macro 15 Pattern Macro 16 Pattern Macro Pattern Macro 18 Pattern Macro 19 Pattern Macro 20 Pattern Macro 21 Pattern Macro 22 Pattern Macro 23 Pattern Macro 24 Pattern Macro 25 Pattern Macro 26 Pattern Macro 27 Pattern Macro 28 Pattern Macro 29 PATTERN ROTATION – *CLOCKWISE / *COUNTERCLOCKWISE STOP *Clockwise Paltern Rotation from FAST to SLOW STOP *Counterclockwise Pattern Rotation from SLOW to FAST STOP PATTERN ROTATION – *HORIZONTAL / *VERTICAL STOP *Horizontal Pattern Rotation from FAST to SLOW STOP *Vertical Pattern Rotation from SLOW to FAST STOP 32 SNIPER 2RTM User Manual ver 3

****** Page 33 ******

ELATIONO SNIPER 2RTM elation lighting. com DMX Channel Values / Functions Version 3 (20 DMX Channels) Specifications are subject to change without any prior written notice, *Rota ion direction of eftects depends on the orientation of the fixture head. MODE / CHANNEL VALUE 0-127 128055 0-63 64-127 128-189 190-193 194-255 0-7 8-255 0-127 128-189 190-193 194955 0-7 8-15 16-131 132-139 140-181 182-189 190931 232-239 240-247 248-255 0-255 0-39 40-59 60-79 80-84 85-8/ 88-90 91-93 94-96 97-99 100-109 110-119 120-129 130-255 FUNCTION 8 9 10 11 12 13 14 16 10 12 13 14 16 18 12 13 14 15 16 18 20 12 13 14 15 16 18 PATTERN ZOOM Pattern ZOOM Manual Pattern ZOOM SLOW to FAST BEAM ROTATION 00 to 3600 Shaking *Clockwise Rotation FAST to SLOW STOP *Counterclockwise Rotation SLOW to FAST PRISM PRISM OFF PRSIM ON PRISM ROTATION PRISM Indexing *Clockwise PRISM Rotation FAST to SLOW STOP *Counterclockwise PRISM Rotation SLOW to FAST SHUTTER, STROBE BLACKOUT OPEN STROBE SLOW to FAST OPEN FAST OPEN to SLOW CLOSE OPEN FAST CLOSE to SLOW OPEN OPEN RANDIJM STROBE OPEN DIMMER INTENSIIY Dimmer Intensity O to 100% FUNCTIONS NO FUNCTION LAMP ON I-AMP OFF ALL MOTORS Reset PAN / TILT Motors Reset COLOR Motor Reset GOBO Motor Reset SHUTTER & DIMMER Motors Reset OTHER Motors Reset ENABLE BLACKOUT WHILE PAN/TILT MOVEMENT ENABLE BLACKOUT WHILE COLOR CHANGE ENABLE BLACKOUT WHILE GOBO CHANGE NO FUNCTION 33 SNIPER 2RTM User Manual ver 3

****** Page 34 ******

ELATIONO SNIPER 2RTM elation lighting. com DMX Channel Values / Functions Version 3 (20 DMX Channels) Specifications are subject to change without any prior written notice, *Rota ion direction of eftects depends on the orientation of the fixture head. MODE / CHANNEL VALUE FUNCTION 14 16 18 20 19 0-255 20 0-255 PAN SHAKING MOVEMENT RANGE PAN SHAKING Movement Range Adjustment TILT SHAKING MOVEMENT RANGE TILT SHAKING Movement Range Adjustment 34 SNIPER 2RTM User Manual ver 3

****** Page 35 ****** elationlighting.com O Disconnect power before cleaning or maintenance. CLEANING Frequent cleaning is recommended to insure proper function, optimized light output, and an extended life. The frequency of cleaning depends on the environment in which the fixture operates: damp, smoky or particularly dirty environments can cause greater accumulation of dirt on the fixture’s optics. Clean the external lens surface at least every 20 days with a soft cloth to avoid dirt/debris accumulation. Never use alcohol, solvents, or ammonia based cleaners. MAINTENANCE Regular inspections are recommended to insure proper function and extended life, There are no user serviceable parts inside this fixture, please refer all other service issues to an authorized Elation service technician. Should you need any spare parts, please order genuine parts from your local Elation dealer. Please refer to the following points during routine inspections: A detailed electric check by an approved electrical engineer every 3 months, to make sure the circuit contacts are in good condition and prevent overheating. Be sure all screws and fasteners are securely tightened at all times, Lose screws may fall out during normal operation resulting in damage or injury, Check for any deformations on the housing, color lenses, rigging hardware and rigging points (ceiling, suspension, trussing). Deformations in the housing could a low for dust to enter into the fixture, Damaged rigging points or unsecured rigging could cause the fixture to fall and seriously injure a person(s). Inspect all moving parts and make sure there are no signs of wear and rotate/move without imbalances. Electric power supply cables must not show any damage, material fatigue or sediments. Never remove the ground prong from the power cable. 35 SNIPER 2RTM User Manual ver 3

****** Page 36 ****** elationlighting. com FEATURES Multi Effect Luminaire, Beam, Scanner, Laser Simulator 30 Precision Beam 3 Facet Rotating Prism X / Y and Z High-Speed Mirror System SOURCE 132W Platinum 2R Lamp 6,000 Hour Average Life EFFECTS Strobe Electronic Dimmer 3 Facet Rotating Prism Multiple Pattern Macros COLOR (14) Dichroic Colors + White GOBOS (17) Gobos + Open CONTROL / CONNECTIONS (4) DMX Channel Modes (14/ 16/ 18 / 20) 4 Button Control Panel 5pin DMX In/Out powerCON In/Out SIZE / WEIGHT Length: 14.2″ (361 mm) Width: 120″ (305mm) Vertical Height: 1 1.6″ (295mm) Weight: 21 JO lbs, (9.5 kg) ELECTRICAL / THERMAL AC 100-240V – 50/60Hz 220W Max Power Consumption Multiple Unit Power Linking (max 7 @120V / 14 @230V) 1 040F (400C) Max Ambient Temperature APPROVALS / RATINGS CE I IP20 c US Intertek Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice. 36 SNIPER 2RTM User Manual ver 3

****** Page 37 ******

elation lighting. com COLORS 1. LIGHT RED 8. LIGHT PINK 2, BLUE 9. YELLOW GREEN GOBOS PHOTOMETRIC DATA o o 3. GREEN PEACOCK BLUE IOm 4. YELLOW MEDIUM PINK O 15m m 15 lux 5. ORANGE 12. MEDIUM PURPLE ft 49.2 fc 6. MAGENTA 18. PINEAPPLE YELOW 20m 7. LAVENDAR 14. CONGO BLUE Beam 25m 5m m Distance 5 3′ Beam Diameter 0.25 Photometrics lux ft 16.4 fc m 10 lux ft 32.8 fc m 20 lux ft 65.6 fc m 25 lux ft 82.0 fc FULL ON 45.010 4,181 Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice. 37 SNIPER 2RTM User Manual ver 3

****** Page 38 ****** elation lighting. DIMENSIONAL DRAWINGS 14.2″ (361 mm) 12.0″ (305mm)

11.6″ com 8.0″ (295mm) (203mm) o 9.8″ (249mm) Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice. ORDER CODE TRIGGER CLAMP DRCSNIPER EWDMXSYSTEM EWDMXT EWDMXR PLC3 PLC6 AC5PDMX5PRO ITEM Heavy Duty Wrap Around Hook Style Clamp Six-Pack Road Case For Sniper 21? TM Wireless DMX System (l Transmitter, 1 Receiver) Wireless DMX Transmitter Wireless DMX Receiver 3 (1 m) powerCON PRO Link Cable 6 (1 18m) powerCON PRO Link Cable 5 ft. (1 15m) 5pin PRO DMX Cable Additional Cable Lengths Available 38 SNIPER 2RTM User Manual ver 3

FREE ENGLISH PDF

OPERATING INSTRUCTIONS

USER GUIDE – USER MANUAL

OWNER GUIDE – OWNER MANUAL

REFERENCE GUIDE – REFERENCE MANUAL

INSTRUCTION GUIDE – INSTRUCTION MANUAL



ELATION PROFESSIONAL SNIPER 2R (01) PDF MANUAL

Leave a comment, question, review or page error below. Account not required.

This site uses Akismet to reduce spam. Learn how your comment data is processed.