Free English DRUM PLUTO 4 (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.


CLICK HERE TO DOWNLOAD DRUM PLUTO 4 (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

How should I store my DRUM PLUTO 4 cargo pump?

To properly store your DRUM PLUTO 4 pump, please follow these steps:

1. Store in a dry and heated building.

2. Handle carefully and keep ports plugged to prevent ingress of dirt.

3. Rotate the pump shaft occasionally to prevent seals from sticking.


What is required on the suction side when mounting the DRUM PLUTO 4 pump?

The DRUM PLUTO 4 pump is built with fine clearances. It is essential that a fine mesh filter is fitted on the suction side of the pump to prevent damage from foreign bodies entering the pump. If a reverse flow valve is fitted, a filter is also required on the other side of the pump.


How should the DRUM PLUTO 4 pump be oriented during mounting?

The DRUM PLUTO 4 pump should be mounted with its shaft as near to a horizontal plane as possible. However, it can be inverted or side-mounted if required. In such cases, it must be supported by both sets of feet.


What are the requirements for the propshaft installation on the DRUM PLUTO 4?

The angle and length of the propshaft must be kept to an absolute minimum. If this cannot be avoided, the propshaft should be balanced. The maximum angle of the propshaft under any conditions is approximately 12 degrees.


How should the power take-off shaft be aligned with the DRUM PLUTO 4 pump?

The centre line of the power take-off shaft must be parallel with the centre line of the DRUM PLUTO 4 pump.


What precautions should be taken when connecting pipework to the DRUM PLUTO 4?

When bolting the pipework to the pump (or its reverse flow valve), care should be taken to prevent distortion of the body by misalignment. If a reverse flow valve is fitted, adequate support should be given to it.


What should I do if water enters my DRUM PLUTO 4 pump?

Should water enter the DRUM PLUTO 4 pump, oil should be flushed through it immediately to prevent rusting.


What are the recommendations for the pipework connected to the DRUM PLUTO 4 pump?

The length of the suction pipe should be kept to an absolute minimum, and its bore should be as large as the pump branches. The delivery pipework and hose should ideally be the same bore as the pump branches. To ensure full output from this high-capacity pump, it is recommended that the pump is mounted on the trailer portion of articulated road tankers to achieve good suction conditions.


Where should the relief valve and spring be fitted on the DRUM PLUTO 4?

Ensure that the relief valve and spring are fitted in the suction side of the DRUM PLUTO 4 pump. See the “PUMP ROTATION – FLOW DIRECTION” diagram for orientations of different drive options and refer to Service Instructions for details on how to interchange the relief valve and blanking plate.


What is the standard relief valve setting for the DRUM PLUTO 4?

The standard relief valve setting is 85psi (6Kp/cm²). Alternative spring settings are available on request. The DRUM PLUTO 4 is fitted with a 2-stage relief valve as standard, which causes the pressure to drop by approximately 25psi (1.75Kp/cm²) when on full bypass, thereby reducing hose pressure and horsepower absorbed.


What types of products are unsuitable for the DRUM PLUTO 4 pump?

The DRUM PLUTO 4 pump has an internal bearing design and therefore must not be used to handle corrosive or abrasive products.


What is the viscosity handling capability of the DRUM PLUTO 4 pump?

The DRUM PLUTO 4 pump is suitable for handling viscosities up to 10,000 seconds RI (2,500 c.St.). For products with higher viscosities, please contact Drum.


What procedure should be followed after discharging liquids with thermo-setting properties using the DRUM PLUTO 4?

You must thoroughly flush out the DRUM PLUTO 4 pump under pressure after discharging liquids with thermo-setting properties. Failure to do so can cause serious damage when the pump is next started.


How should I operate the DRUM PLUTO 4 when handling viscous products with a reverse flow valve?

When handling viscous products using a DRUM PLUTO 4 with a reverse flow valve, start with the valve in the neutral position. Then, gradually move the handle to increase the flow. This procedure will reduce the stock load on the drive system.


How can I prevent the reverse flow valve on my DRUM PLUTO 4 from sticking?

If the reverse flow valve on your DRUM PLUTO 4 is used infrequently, rotate it once a day to prevent sticking.


How do I achieve the optimum discharge rate with my DRUM PLUTO 4?

For the optimum discharge rate, start with a slow drive speed and gradually increase it until the pump starts to become noisy. Then, reduce the speed slightly until the noise disappears.


How do I clear the lines of my DRUM PLUTO 4 pump?

To clear the pump lines, increase the speed or pump just prior to the compartment becoming empty. Revving the DRUM PLUTO 4 pump after it starts to pull air will not clear the lines. Do not run the pump at this elevated speed for more than approximately 60 seconds.


What are the operational restrictions for the DRUM PLUTO 4 pump?

Please observe the following restrictions when operating your DRUM PLUTO 4:

1. Do not run the pump dry.

2. This pump must not be run on full bypass for more than 3 minutes.


Does the DRUM PLUTO 4 require routine maintenance?

No routine maintenance is required for the DRUM PLUTO 4. The product being pumped lubricates the bearings and synchronising gears.


What should I do if my DRUM PLUTO 4 pump becomes noisy during operation?

Should the DRUM PLUTO 4 pump become noisy during normal operation, it is essential that it is immediately removed from service and the reasons are investigated. It is essential the pump is not stripped or even partially stripped as this will invalidate the warranty.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD DRUM PLUTO 4 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.