Free English DAIKIN FFQ09W2VJU9 (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.


CLICK HERE TO DOWNLOAD DAIKIN FFQ09W2VJU9 (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.


How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.


What should I do if my DAIKIN FFQ09W2VJU9 operation does not start soon after I press the ON/OFF button?

This is to protect the DAIKIN FFQ09W2VJU9. You should wait for about 3 minutes.


What should I do if the DAIKIN FFQ09W2VJU9 operation does not start after reselecting the mode?

This is to protect the DAIKIN FFQ09W2VJU9. You should wait for about 3 minutes.


Why does no air come out of my DAIKIN FFQ09W2VJU9 during HEAT operation?

The DAIKIN FFQ09W2VJU9 is warming up. Wait for about 1 to 4 minutes.


Why does no air come out of my DAIKIN FFQ09W2VJU9 during defrosting operation?

During defrosting operation, hot air does not flow out of the DAIKIN FFQ09W2VJU9 indoor unit.


Why does no air come out of my DAIKIN FFQ09W2VJU9 immediately after the circuit breaker is turned on?

The DAIKIN FFQ09W2VJU9 is preparing to operate. Wait for about 3 to 20 minutes.


Why does the HEAT operation on my DAIKIN FFQ09W2VJU9 stop suddenly and make a flowing sound?

The system of the DAIKIN FFQ09W2VJU9 is taking away the frost on the outdoor unit. You should wait for about 4 to 12 minutes.


Why does the outdoor unit of my DAIKIN FFQ09W2VJU9 emit water or steam in HEAT mode?

The frost on the outdoor unit melts into water or steam when the DAIKIN FFQ09W2VJU9 is in defrost operation.


Why does the outdoor unit of my DAIKIN FFQ09W2VJU9 emit water in COOL or DRY mode?

Moisture in the air condenses into water on the cool surface of the DAIKIN FFQ09W2VJU9 outdoor unit piping and drips.


Why does mist come out of my DAIKIN FFQ09W2VJU9 indoor unit?

This happens when the air in the room is cooled into mist by the cold airflow during cooling operation of the DAIKIN FFQ09W2VJU9.


What causes an odor from the DAIKIN FFQ09W2VJU9 indoor unit?

This happens when smells of the room, furniture, or cigarettes are absorbed into the DAIKIN FFQ09W2VJU9 and discharged with the airflow.


Why does the outdoor fan of my DAIKIN FFQ09W2VJU9 rotate while the air conditioner is not in operation?

After operation of the DAIKIN FFQ09W2VJU9 is stopped, the outdoor fan continues rotating for another 1 minute for system protection. If the outdoor temperature is very high while the unit is not in operation, the outdoor fan starts rotating for system protection.


What should I do if the DAIKIN FFQ09W2VJU9 operation stops suddenly and the OPERATION lamp is on?

For system protection, the DAIKIN FFQ09W2VJU9 may stop operating on a sudden large voltage fluctuation. It automatically resumes operation in about 3 minutes. If in a multi system, ensure all indoor units are set to the same operation mode.


What should I check if my DAIKIN FFQ09W2VJU9 does not operate and the OPERATION lamp is off?

Check if the circuit breaker has turned OFF or a fuse has blown. Ensure there is no power failure. Check if batteries are set in the remote controller and if the timer setting is correct.


What should I check if the cooling or heating effect of my DAIKIN FFQ09W2VJU9 is poor?

Check the following for your DAIKIN FFQ09W2VJU9: Are the air filters clean? Is there anything blocking the air inlet or the outlet of the indoor and the outdoor units? Is the temperature setting appropriate? Are the windows and doors closed? Are the airflow rate and the air direction set appropriately?


What should I do if my DAIKIN FFQ09W2VJU9 stops suddenly and the OPERATION lamp is blinking?

Check if the air filters of the DAIKIN FFQ09W2VJU9 are clean. Check if there is anything blocking the air inlet or the outlet of the indoor and the outdoor units. Clean the air filters or take all obstacles away, turn the circuit breaker OFF, turn it ON again, and try operating the air conditioner with the remote controller.


What should I do if an abnormal functioning happens during the operation of my DAIKIN FFQ09W2VJU9?

The DAIKIN FFQ09W2VJU9 may malfunction with lightning or radio waves. Turn the breaker OFF, turn it ON again and try operating the air conditioner with the remote controller.


How do I clean the air filter on the DAIKIN FFQ09W2VJU9?

Clean the air filter when the air filter cleaning time indicator lamp on the decoration panel lights up or when “Time to clean filter” displays on the wired remote controller.

1. Open the suction grille by pushing the 2 catches away from you and slowly opening the suction grille.

2. Remove the air filter by pulling the knobs downward to disconnect the hooks.

3. Clean the air filter with a vacuum cleaner or wash it with water.

4. If the dust does not come off easily, wash it using a soft brush and a neutral detergent, then let it dry in the shade.

5. Reattach the air filter by hooking one side on to the protrusions on the suction grille and pushing the other side into place.

6. Close the suction grille.

7. Reset the filter sign in accordance with the instructions in the operation manual for the remote controller.


How do I clean the suction grille (type A) on the DAIKIN FFQ09W2VJU9?

1. Push the 2 catches away from you and slowly open the suction grille.

2. Open the suction grille until it is 45 degrees to the ceiling and then lift it upward to remove it.

3. Remove the air filter.

4. Wash the suction grille with a soft bristle brush and a neutral detergent or water, and dry thoroughly.

5. If very dirty, directly apply the type of detergent used for cleaning ventilation fans or ovens, wait for about 10 minutes, and then rinse with water.

6. Reattach the air filter.

7. Reattach the suction grille by performing the removal steps in reverse.

8. Close the suction grille.


How do I clean the suction grille (type B) on the DAIKIN FFQ09W2VJU9?

1. Push the 2 catches away from you and slowly open the suction grille.

2. Open the suction grille so that it hangs by the hinges at 90 degrees to the ceiling, then pinch the wire catches inward to remove the suction grille.

3. Remove the air filter.

4. Wash the suction grille with a soft bristle brush and a neutral detergent or water, and dry thoroughly. If very dirty, directly apply the type of detergent used for cleaning ventilation fans or ovens, wait for about 10 minutes, and then rinse with water.

5. Reattach the air filter.

6. Reattach the suction grille.

7. Close the suction grille.


What should I do to the DAIKIN FFQ09W2VJU9 prior to a long period of non-use?

1. Operate the FAN mode for several hours to dry out the inside of the DAIKIN FFQ09W2VJU9.

2. After operation stops, turn off the circuit breaker for the DAIKIN FFQ09W2VJU9.

3. Clean the air filter and reattach it.

4. To prevent battery leakage, take out the batteries from the remote controller (only for the wireless remote controller).


What are the operating conditions for the DAIKIN FFQ09W2VJU9 in COOL or DRY mode?

The following table lists the operating conditions for the DAIKIN FFQ09W2VJU9 in COOL or DRY mode.

Mode Operating conditions
COOL / DRY Outdoor temperature: [MXS, MXL, MXLH models]: 14 to 115°F (-10 to 46°C); [RX models]: 50 to 115°F (10 to 46°C). Note: With jumper cut, -4°F (-20°C) is supported if air direction adjustment grille is installed. Indoor temperature: 64 to 90°F (18 to 32°C). Indoor humidity: 80% max.

What are the operating conditions for the DAIKIN FFQ09W2VJU9 in HEAT mode?

The following table lists the operating conditions for the DAIKIN FFQ09W2VJU9 in HEAT mode.

Mode Operating conditions
HEAT Outdoor temperature: [MXS models]: 5 to 75°F (-15 to 24°C); [MXL models]: 5 to 75°F (-15 to 24°C), or -13 to 75°F (-25 to 24°C) if drain pan heater is installed; [MXLH models]: -13 to 75°F (-25 to 24°C); [RX models]: 5 to 75°F (-15 to 24°C). Indoor temperature: 50 to 86°F (10 to 30°C).

What steps should I take if there is a burning smell or other abnormalities with the DAIKIN FFQ09W2VJU9?

Stop operation and turn off the circuit breaker immediately. Continued operation in an abnormal condition may result in problems, electric shock, or fire. Consult the dealer where you bought the DAIKIN FFQ09W2VJU9.


What symptoms indicate I should call my dealer immediately regarding my DAIKIN FFQ09W2VJU9?

Call your dealer immediately if any of the following symptoms take place with your DAIKIN FFQ09W2VJU9: The power cord is abnormally hot or damaged; An abnormal sound is heard during operation; The circuit breaker cuts off the operation frequently; A switch or a button often fails to work properly; There is a burning smell; Water leaks from the indoor unit.


How does the DAIKIN FFQ09W2VJU9 behave after a power failure?

The DAIKIN FFQ09W2VJU9 automatically resumes operation in about 3 minutes.


What safety precaution should I take if there is a risk of lightning?

If there is a risk lightning could strike in the neighborhood, stop operation of the DAIKIN FFQ09W2VJU9 and turn off the circuit breaker to protect the system.


Are there restrictions on cleaning materials for the DAIKIN FFQ09W2VJU9?

For cleaning the DAIKIN FFQ09W2VJU9, do not use any of the following: Water hotter than 104°F (40°C); Volatile liquid such as benzene, gasoline, and thinner; Polishing compounds or liquid insecticide; Rough materials such as a scrubbing brush; Sprays such as deodorizers.


Can I use the DAIKIN FFQ09W2VJU9 to cool food or animals?

No, do not use the DAIKIN FFQ09W2VJU9 for cooling precision instruments, food, plants, animals, or works of art. It should only be used for comfort cooling or heating.


What should I do if I suspect a refrigerant leak in my DAIKIN FFQ09W2VJU9?

Consult your dealer. Refrigerant gas is heavier than air and replaces oxygen. A massive leak could lead to oxygen depletion, especially in basements, and an asphyxiation hazard could occur leading to serious injury or death.


Is it safe to clean the inside of the DAIKIN FFQ09W2VJU9 myself?

No, incorrect cleaning of the inside of the DAIKIN FFQ09W2VJU9 could make the plastic parts break and cause water leakage or electric shock. Consult with your installation contractor for cleaning.


Can I use flammable spray near the DAIKIN FFQ09W2VJU9?

No, never use flammable spray such as hair spray, lacquer, or paint near the DAIKIN FFQ09W2VJU9. Flammable spray may cause a fire.


What is the risk of touching the heat exchanger fins of the DAIKIN FFQ09W2VJU9?

The heat exchanger fins are sharp enough to cut. To avoid injury, wear gloves or cover the fins while working around the DAIKIN FFQ09W2VJU9.


Can I remove the front panel of the DAIKIN FFQ09W2VJU9 controller?

No, never touch the internal parts of the controller and do not remove the front panel because some parts inside are dangerous to touch. To check and adjust internal parts of the DAIKIN FFQ09W2VJU9, contact your dealer.


What should I do if a fuse blows in the DAIKIN FFQ09W2VJU9?

When a fuse blows out, never replace it with one of incorrect ampere ratings or different wires. Always replace any blown fuse in the DAIKIN FFQ09W2VJU9 with a fuse of the same specification.


Should I turn off the power immediately after stopping the DAIKIN FFQ09W2VJU9?

No, do not turn off the power immediately after stopping operation of the DAIKIN FFQ09W2VJU9. Always wait for at least 5 minutes before turning off the power. Otherwise, water leakage may occur.


Are there any special considerations for the DAIKIN FFQ09W2VJU9 if a burner is used in the same room?

If equipment utilizing a burner is used in the same room as the DAIKIN FFQ09W2VJU9, there is the danger of oxygen deficiency which could lead to an asphyxiation hazard. Be sure to ventilate the room sufficiently to avoid this hazard.


What should I do to prevent injury from the DAIKIN FFQ09W2VJU9 air inlet or air outlet?

Do not put a finger or other objects into the air inlet or air outlet of the DAIKIN FFQ09W2VJU9. The fan is rotating at high speed and will cause injury.


Should I allow children to play on or around the DAIKIN FFQ09W2VJU9?

No, do not allow children to play on or around the DAIKIN FFQ09W2VJU9 to prevent injury.


Can I use the DAIKIN FFQ09W2VJU9 with a room-fumigation type of insecticide?

No, do not operate the DAIKIN FFQ09W2VJU9 when using a room-fumigation type of insecticide. Failure to observe this could cause the chemicals to be deposited in the unit and can endanger the health of those who are hypersensitive to chemicals.


Why should I check the DAIKIN FFQ09W2VJU9 unit foundation?

Check the DAIKIN FFQ09W2VJU9 unit foundation for damage on a continuous basis, especially if it has been in use for a long time. If left in a damaged condition the unit may fall and cause injury.


What should I do if the drainpipe of the DAIKIN FFQ09W2VJU9 is clogged?

If no water is discharged from the drainpipe while the DAIKIN FFQ09W2VJU9 is in the cooling mode, the drainpipe may be clogged with dust or dirt and water leakage from the indoor unit may occur. Stop operating the DAIKIN FFQ09W2VJU9 and contact your dealer.


Are there precautions for cleaning the DAIKIN FFQ09W2VJU9 controller panel?

Do not wipe the DAIKIN FFQ09W2VJU9 controller operation panel with benzine, thinner, chemical dust cloth, etc. The panel may get discolored or the coating can peel off. If it is heavily dirty, soak a cloth in water-diluted neutral detergent, squeeze it well and wipe the panel clean, then wipe it with another dry cloth.


How can I protect the DAIKIN FFQ09W2VJU9 from snow?

Take snow protection measures for the DAIKIN FFQ09W2VJU9. Contact your dealer for the details of snow protection measures, such as the use of a snow protection hood.


What should I consider regarding the operating sound of the DAIKIN FFQ09W2VJU9?

Pay attention to operating sound when choosing a location for the DAIKIN FFQ09W2VJU9. Ensure it is a place that can sufficiently withstand the weight and suppress operating sound and vibration, and ensure that warm air or sound from the outdoor unit does not annoy neighbors.


Are there locations where I should not install the DAIKIN FFQ09W2VJU9?

Do not use the DAIKIN FFQ09W2VJU9 in the following places: Places with a mist of mineral oil (like cutting oil); coastal areas with salt in the air; hot springs with sulfur in the air; factories with fluctuating power voltage; cars, boats, and other vehicles; kitchens where oil may splatter or steam exists; locations producing electromagnetic waves; places with acid or alkaline mist; or places where fallen leaves or weeds can accumulate.


What should I do if the DAIKIN FFQ09W2VJU9 in operation generates unusual noise?

Consult your dealer if the DAIKIN FFQ09W2VJU9 in operation generates unusual noise.


Is it safe to touch the switch on the DAIKIN FFQ09W2VJU9 with wet fingers?

No, do not touch the switch with wet fingers. Touching a switch with wet fingers can cause electric shock from the DAIKIN FFQ09W2VJU9.


How should I handle the packing materials for the DAIKIN FFQ09W2VJU9?

Safely dispose of the packing materials for the DAIKIN FFQ09W2VJU9. Nails and other metal or wooden parts may cause stabs or other injuries. Tear apart and throw away plastic packaging bags so that children will not play with them, as they face the danger of death by suffocation.


Can I install the DAIKIN FFQ09W2VJU9 in an area with flammable materials?

No, do not install the DAIKIN FFQ09W2VJU9 in an area where flammable materials are present due to risk of explosion resulting in serious injury or death.


Should I keep the DAIKIN FFQ09W2VJU9 remote controller away from children?

Yes, the remote controller for the DAIKIN FFQ09W2VJU9 should be kept away from children so they cannot play with it.


What are the rules regarding the DAIKIN FFQ09W2VJU9 refrigerant and disposal?

Dismantling of the DAIKIN FFQ09W2VJU9, disposal of the refrigerant, oil, and additional parts, should be done in accordance with the relevant local, state, and national regulations.


How do I prevent the remote controller of the DAIKIN FFQ09W2VJU9 from being damaged?

Never press the button of the DAIKIN FFQ09W2VJU9 remote controller with a hard, pointed object, as it may be damaged. Also, do not pull or twist the electric wire of the remote controller as it may cause the unit to malfunction.


Can I use electrical appliances that produce open flames near the DAIKIN FFQ09W2VJU9?

Do not place appliances that produce open flames in places that are exposed to the airflow of the DAIKIN FFQ09W2VJU9 or under the indoor unit, as it may cause incomplete combustion or deformation of the unit due to the heat.


What should I do if the DAIKIN FFQ09W2VJU9 indoor unit has unusual odors?

If the DAIKIN FFQ09W2VJU9 indoor unit gives out an odor, we recommend you to have the indoor unit washed by a technician. Consult your dealer where you bought the air conditioner.


Is the DAIKIN FFQ09W2VJU9 intended for use by young children or infirm persons?

The DAIKIN FFQ09W2VJU9 is not intended for use by young children or infirm persons without supervision.


Can I spray the DAIKIN FFQ09W2VJU9 unit with deodorizers?

No, do not spray the DAIKIN FFQ09W2VJU9 unit with any deodorizers, etc. It may cause the unit to malfunction.


How can I ensure the DAIKIN FFQ09W2VJU9 does not get wet?

Never let the indoor unit or the remote controller of the DAIKIN FFQ09W2VJU9 get wet, as water can cause an electric shock or a fire.


Can I inspect or service the DAIKIN FFQ09W2VJU9 by myself?

No, never inspect or service the DAIKIN FFQ09W2VJU9 by yourself. Contact a qualified service person to perform this work.


What should I do if I have to move or reinstall the DAIKIN FFQ09W2VJU9?

Contact your dealer to move and reinstall the DAIKIN FFQ09W2VJU9. Incomplete installation may result in water leakage, electric shock, and fire.


Is it okay to remove the fan guard of the DAIKIN FFQ09W2VJU9?

No, never remove the fan guard of the DAIKIN FFQ09W2VJU9. A fan rotating at high speed without the fan guard is very dangerous.


Can I use the DAIKIN FFQ09W2VJU9 with a multi system?

Yes, the DAIKIN FFQ09W2VJU9 is part of a multi system. In a multi system, COOL, DRY, and FAN operations can be used at the same time. AUTO operation is available when selecting the same operation mode as that of the room with the first unit to be turned on.


How does the priority room setting work for the DAIKIN FFQ09W2VJU9 in a multi system?

The priority room setting for the DAIKIN FFQ09W2VJU9 requires initial programming during installation. The designated room takes priority. For example, if Room A is the priority room and is set to COOL, if other rooms are set to COOL, DRY, or FAN, the current mode is maintained. If they are set to HEAT, they enter standby until Room A stops operating.


CLICK HERE TO DOWNLOAD DAIKIN FFQ09W2VJU9 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.