What governing codes and ordinances should be observed during planning and installation?

Observe all governing codes and ordinances during planning and installation. Contact the local building department for further information. This appliance must be installed in accordance with the accompanying installation instructions.


To prevent an electric shock hazard, what power supply specifications are required?

The power supply must meet the specifications stated. It is the owner’s responsibility to make sure that the electrical service meets electrical requirements and that the electrical outlet has been properly installed.


What kind of electrical plug does the cooktop come with and where is it connected?

The cooktop is supplied with a factory installed, 40-inch, three-prong, grounding electrical plug. It is connected to the chassis at the bottom right rear corner.


What kind of electrical outlet should the electrical plug be connected to?

It must be connected to a dedicated, grounded three-prong electrical outlet installed by a licensed electrician.


What standards should the electrical installation comply with?

The electrical installation, including minimum supply wire size and grounding, must be done in accordance with National Electric Code ANSI/NFPA 70 and local codes and ordinances.


Where can a copy of the National Electric Code ANSI/NFPA 70 standard be obtained from?

National Fire Protection Association 1 Batterymarch Park Quincy, Massachusetts 02269-9101


What electrical requirements should be supplied to the electrical outlet?

The correct voltage, frequency and amperage must be supplied to the electrical outlet according to the product data label located on the bottom of the chassis.


Where should the electrical outlet be located?

Be certain to locate the electrical outlet so that the power cord may be easily disconnected if the unit needs service.


What should be checked regarding the gas supply requirements?

Be certain that the cooktop being installed is correct for the gas service being provided (natural gas or LP gas). Also, if operating the cooktop at an altitude above 4000 ft. (1219 m) make sure it is equipped for high altitude operation.


How can I identify if a unit is equipped for LP operation?

Units equipped for LP operation have “LP” in the model number listed on the product data label.


How can I identify if a unit is equipped for high altitude operation?

Units equipped for high altitude operation have an “H” at the end of the model number listed on the product data label.


What codes should the cooktop be installed in accordance with?

Check your local building codes for the proper method of installation. In the absence of local codes, this appliance should be installed in accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54.


What kind of valve must be installed between the gas inlet and the cooktop?

An external manual shut-off valve must be installed between the gas inlet and the cooktop for the purpose of turning on or shutting off gas to the appliance.


What comes with the cooktop from the factory regarding the gas line?

The cooktop comes from the factory with a regulator in the shipping carton. Use only the regulator provided. The regulator must be installed in the gas line that runs from the cooktop gas inlet to the gas shut off valve.


What size of regulator do models SGM304 and SGM365 come with?

Models SGM304 and SGM365 come with a 1/2” regulator.


What size of regulator does model SGM466 come with?

Model SGM466 comes with a 3/4” regulator, approved for connection to a 1/2” house gas supply.


Where is the cooktop gas connection located?

The cooktop gas connection is located on the bottom of the cooktop in the back right corner as you face the front of the unit.


What is the minimum clearance that should be allowed between the bottom of the cooktop chassis and all combustible surfaces?

Allow a minimum ¼” (6 mm) clearance between the bottom of the cooktop chassis and all combustible surfaces, including the upper edge of a drawer installed below the cooktop.


Where should the gas supply piping, gas shut-off valve, and the electrical outlet be located?

The gas supply piping, gas shut-off valve and the electrical outlet must be located so they do not interfere with the cooktop when it is installed. If installing another appliance in the cabinet below, allow for the routing of gas and electrical service behind it.


What kind of access should the installation allow for?

The installation must allow for the following:

  • Access to the gas shut-off valve and regulator when the unit is installed.
  • Access to the electrical outlet when the cooktop is in place. The 40” (1016 mm) power cord must be able to reach the electrical outlet.
  • Access to the underside of the cooktop for service and inspection purposes.
  • Clearance inside the cabinet to allow for proper hold down bracket installation.

What should not be installed below the cooktop to allow access to the utilities and cooktop bottom?

To allow access to the utilities and cooktop bottom, a fixed shelf should not be installed below the cooktop.


What should be avoided regarding cabinet storage space?

To reduce the risk of personal injury caused by reaching over a hot appliance, avoid locating cabinet storage space directly above the cooktop.


What instructions should be followed regarding the countertop?

Follow the countertop manufacturer’s instructions regarding the minimum corner radius, use of heat reflective tape, reinforcement of corners, etc.


Where should the cooktop be placed for best performance?

Carefully check the location where the cooktop will be installed. For best performance, the cooktop should be placed away from drafts that may be caused by doors, windows and heating and air conditioning outlets.


What is the minimum clearance to combustible side wall, above counter both sides?

7 1/2” (191 mm) Min. to combustible side wall, above counter both sides