What should I do before operating the CECOTEC READY WARM 800 THERMAL BLACK for the first time?

Allow the CECOTEC READY WARM 800 THERMAL BLACK to operate at maximum temperature for 2-3 hours in a ventilated place in order to eliminate all manufacturing wastes.


How do I correctly set up the CECOTEC READY WARM 800 THERMAL BLACK for floor assembly?

Place the stand on the bottom part of the CECOTEC READY WARM 800 THERMAL BLACK, each one on one side, and screw them. Make sure they are properly fixed.


What are the steps for wall assembly of the CECOTEC READY WARM 800 THERMAL BLACK?

1. Before installing the CECOTEC READY WARM 800 THERMAL BLACK, make sure the appliance is placed at a minimum safety distance of 20 cm from any obstacle (walls, shelves, floor…).

2. Drill 2 holes on the wall with 140 mm between them.

3. Attach the wall supports to the wall using the studs and screws provided.

4. Make sure the smaller-diameter side of the supports is hung from the wall.

5. Screw the wall support accessory onto the 2 holes on the back-bottom part of the CECOTEC READY WARM 800 THERMAL BLACK. Make sure the side with just 1 hole is against the wall.

6. Hang the appliance from the support.

7. Once hung on the wall, mark the free hole of the wall support accessory.

8. Remove the appliance from the wall, drill a hole where the mark is and introduce the corresponding stud.

9. Finally, hang the appliance on the brackets and screw the mounting plate to the wall.


How is the automatic lock feature on the CECOTEC READY WARM 800 THERMAL BLACK activated and deactivated?

The buttons on the device’s control panel will block if no button is pressed for 1 minute during operation.

To unlock it, press (-) for 3 seconds.


What are the manual operating modes available for the CECOTEC READY WARM 800 THERMAL BLACK?

The CECOTEC READY WARM 800 THERMAL BLACK has 3 operating modes in manual mode:

Day mode: The temperature can be adjusted from 5 °C to 35 °C.

Sleep mode: The temperature can be adjusted from 5 °C to 35 °C.

Anti-frost mode: The temperature can be adjusted from 5 °C to 15 °C.


What is the warning regarding temperature setting for the CECOTEC READY WARM 800 THERMAL BLACK in manual mode?

For the CECOTEC READY WARM 800 THERMAL BLACK to operate correctly, the set temperature must always be higher than the room temperature. The panel will display the room temperature. When setting the desired temperature, select a few more degrees than desired ones, as the temperature shown on the display is the one next to the device and not the real room one.


What are the steps to turn on the CECOTEC READY WARM 800 THERMAL BLACK?

1. Connect the CECOTEC READY WARM 800 THERMAL BLACK to a power supply and turn the power switch on.

2. The control panel will flash and the “°C” symbol, room temperature and power indicator will light up. If this last symbol does not light up, press it.

3. Select the desired operating mode by pressing the corresponding button: Day, Sleep or Anti-frost. The display will show the selected mode.

4. Use the + and – buttons to set the desired temperature for the selected mode. During the temperature setting, the “°C” icon will blink.

5. Once the desired temperature has been set, the display will show the room temperature again.

6. Repeat the above steps to set the temperature for the other modes.

7. Use the on/off button to turn the heater on and off.


How does the thermostat function on the CECOTEC READY WARM 800 THERMAL BLACK?

When the CECOTEC READY WARM 800 THERMAL BLACK reaches the set temperature, it will automatically switch off and the icon will turn off.

When the room temperature falls below the set one, the device will automatically turn back on and the icon will light up again.


How can I reset the CECOTEC READY WARM 800 THERMAL BLACK while it is connected and the switch is on?

To reset the CECOTEC READY WARM 800 THERMAL BLACK while it is connected to the power supply and the power switch is on, make sure the device is unlocked or unlock it with the remote control and press the power button (-) for 3 seconds. It can also be switched off and on.


What are the steps to set the current day of the week and time on the CECOTEC READY WARM 800 THERMAL BLACK?

1. Long press the “PROG” button until the display shows “00:00”.

2. The hour digits will blink. Use the + and – buttons to set the desired hour and press “PROG” to save the settings.

3. The minutes digits will blink. Use the + and – buttons to set the desired minutes and press “PROG” to save the settings.

4. The display will show the week calendar (Monday-Sunday, 1-7). Select the current day by pressing + and -. Press “PROG” to save the settings.


What are the steps for setting the weekly schedule for the CECOTEC READY WARM 800 THERMAL BLACK?

1. The display will show the first 2 bars for the first period of time (00:00 – 1:00 am) blinking. It will also show 1 as Monday.

2. Press the desired mode (Day, Sleep or Anti-frost) for the selected time interval.

If you select Sleep mode, the display will show an icon and the bar on the top part will blink.

If you select the Anti-frost mode, the display will show an icon and the bar on the lower part will blink.

If you select Day mode, the display will show an icon and the top and lower bars will blink.

3. Once the first period has been scheduled, press “+” and the next time period’s bars will blink.

4. Repeat these steps up to 24 hours.

5. When all the hours in a day have been scheduled, press “PROG” to end the selected day scheduling and repeat the steps to schedule the 7 days of the week.

6. Once the whole week has been scheduled, press “PROG” and the device will automatically save the settings and operate in the set mode.


What happens to the schedule settings on the CECOTEC READY WARM 800 THERMAL BLACK if it is disconnected from the power supply?

If the CECOTEC READY WARM 800 THERMAL BLACK is disconnected from the power supply, the schedule settings will be saved but the current day and time will be reset.


What are the steps to change the operating mode on the CECOTEC READY WARM 800 THERMAL BLACK if it is currently set to programmed mode?

If the CECOTEC READY WARM 800 THERMAL BLACK is operating under programmed mode, to change it:

1. Press the on button on the remote control twice.

2. Press “PROG”.

3. Select the desired mode and adjust the temperature if necessary, using the + and -buttons.


How can I adjust the temperature when the CECOTEC READY WARM 800 THERMAL BLACK is operating in programmed mode?

1. During operation, press twice the on button on the remote control and use the + and – buttons to select the desired temperature.

2. Once the temperature is set, it will be saved for this mode for future operations, including under manual mode.


How do I clean the outer housing of the CECOTEC READY WARM 800 THERMAL BLACK?

Turn off, unplug the CECOTEC READY WARM 800 THERMAL BLACK from the power supply and allow it cool down before cleaning it.

Use a soft, dry and clean cloth to clean the product’s outer housing.

Do not use abrasive cleaners or scouring pads as they could cause damage to the product’s surface.


What are the technical specifications for the CECOTEC READY WARM 800 THERMAL BLACK?

Product reference: 05330, 05892

Product: ReadyWarm 800 Thermal / ReadyWarm 800 Thermal Black

Power and voltage: 600 W, 220-240 V, 50/60 Hz

Made in China | Designed in Spain


What is the required heat input information for the CECOTEC READY WARM 800 THERMAL BLACK as an electric local space heater?

Item Symbol Value Unit Item Unit
Heating power Type of heat input, for electric storage local space heaters only (single select)
Nominal heat output Pnom 0.60 kW Manual heat charge control with integrated thermostat [no]
Minimum heat output (indicative) Pmin 0.60 kW Manual heat charge control with room and/or outdoor temperature feedback [no]
Maximum continuous heat output Pmax 0.60 kW Electronic heat charge control with room and/or outdoor temperature feedback [no]
Auxiliary electricity consumption Fan assisted heat output [no]
At nominal heat output elmax 0 kW Type of heat output/room temperature control (single select)
At minimum heat output elmin 0 kW Single stage heat output and no room temperature control [no]
In standby mode elSB 0.00094 kW Two or more manual stages, no room temperature control [no]
With mechanic thermostat room temperature control [no]
With electronic room temperature control [no]
Electronic room temperature control plus day timer [no]
Electronic room temperature control plus week timer Yes
Other control options (multiple selections possible)
Room temperature control, with presence detection [no]
Room temperature control, with open window detection [yes]
With distance control option [no]
With adaptive start control [no]
With working time limitation [no]
With black bulb sensor [no]
Contact details: Cecotec Innovaciones S.L. C/de la Pinadeta s/n 46930 Quart de Poblet, Valencia (SPAIN)

What is the required information for the electric local space heaters CECOTEC READY WARM 800 THERMAL BLACK regarding heat input and control options?

Item Symbol Value Unit Item Unit
Heating power Type of heat input, for electric storage local space heaters only (single select)
Nominal heat output Pnom 0.60 kW Manual heat charge control with integrated thermostat [no]
Minimum heat output (indicative) Pmin 0.60 kW Manual heat charge control with room and/or outdoor temperature feedback [no]
Maximum continuous heat output Pmax 0.60 kW Electronic heat charge control with room and/or outdoor temperature feedback [no]
Auxiliary electricity consumption Fan assisted heat output [no]
At nominal heat output elmax 0 kW Type of heat output/room temperature control (single select)
At minimum heat output elmin 0 kW Single stage heat output and no room temperature control [no]
In standby mode elSB 0.00094 kW Two or more manual stages, no room temperature control [no]
With mechanic thermostat room temperature control [no]
With electronic room temperature control [no]
Electronic room temperature control plus day timer [no]
Electronic room temperature control plus week timer Yes
Other control options (multiple selections possible)
Room temperature control, with presence detection [no]
Room temperature control, with open window detection [yes]
With distance control option [no]
With adaptive start control [no]
With working time limitation [no]
With black bulb sensor [no]
Contact details: Cecotec Innovaciones S.L. C/de la Pinadeta s/n 46930 Quart de Poblet, Valencia (SPAIN)