What does the instruction manual cover?
The instruction manual covers Models 1665 / 1666 / 1667 Bench Switching DC Power Supplies.
What does the warranty cover?
B&K Precision Corp. warrants to the original purchaser that its product and the component parts thereof, will be free from defects in workmanship and materials for a period of one year from the date of purchase.
What will B&K Precision Corp. do in case of a defect?
B&K Precision Corp. will, without charge, repair or replace, at its’ option, defective product or component parts. Returned product must be accompanied by proof of the purchase date in the form a sales receipt.
How to obtain warranty coverage in the U.S.A.?
This product must be registered by completing and mailing the enclosed warranty card to B&K Precision Corp., 22820 Savi Ranch Parkway Yorba Linda, CA 92887 within fifteen (15) days from proof of purchase.
What does the warranty not cover?
This warranty does not apply in the event of misuse or abuse of the product or as a result of unauthorized alternations or repairs. It is void if the serial number is alternated, defaced or removed.
Is B&K Precision Corp. liable for consequential damages?
B&K Precision Corp. shall not be liable for any consequential damages, including without limitation damages resulting from loss of use. Some states do not allow limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
What are the safety instructions?
- Do not use this apparatus near water.
- Clean only with dry cloth.
- Do not block any ventilation openings.
- Do not install unit near any heat source or heating emitting devices.
- Prevent the power cord from being walked on or pinched.
- Unplug this unit during lighting storms or when unused for long periods of time.
What precautions should be taken?
- The unit must be used within its specified range.
- The rated input voltages can be found on the rating label at the back the unit.
- Before plugging into the AC supply, check with the rating label.
- Refer all servicing to manufacturer.
What is the warning for Model 1667?
Model 1667 has maximum output voltage up to 60 Vdc. It may be hazardous to touch metal part of the output terminals. User must avoid touching live metal part of the output terminals.
What are the features of these Laboratory Grade Switching DC Power Supplies?
These Laboratory Grade Switching DC Power Supplies were built with coarse and fine output voltage and current limiting controls. Current limiting control with automatic crossover of constant voltage (CV) and constant current (CC) indicators make this series ideal for research and development work in laboratories.
What is the maximum voltage meter display for Model 1665?
Model 1665 only: V meter max. display is 19.99.
What happens when the output voltage is above 19.99V for Model 1665?
Above 19.99 output voltage, the V meter display will indicate a different value.
What are the technical specifications of models 1665, 1666, and 1667?
| Specifications | 1665 | 1666 | 1667 |
|---|---|---|---|
| Output Voltage: | 1-19VDC | 1-40VDC | 1-60VDC |
| Output Voltage Control: | Fine & Coarse | Fine & Coarse | Fine & Coarse |
| Output Current: | 0-10A | 0-5A | 0-3.3A |
| Ripple & Noise (P-P): | 20mV | 20mV | 20mV |
| Load Regulation: | 0.5% + 200mV | 0.5% + 200mV | 0.5% +200mV |
| Line Regulation: | 50mV | 50mV | 50mV |
| Input Voltage: | 100 – 240 VAC, 50Hz / 60Hz | 100 – 240 VAC, 50Hz / 60Hz | 100 – 240 VAC, 50Hz / 60Hz |
| Meter Type: | Digital LED | Digital LED | Digital LED |
| Voltmeter Range: | Auto-Range 31/2digit LED | Auto-Range 3digit LED | Auto-Range 3digit LED |
| Ammeter Range: | Auto-Range 31/2digit LED | Auto-Range 3digit LED | Auto-Range 3digit LED |
| Voltmeter Accuracy: | 1% + 2 counts | 1% + 2 counts | 1% + 2 counts |
| Ammeter Accuracy: | 0.5% + 2 counts | 0.5% + 2 counts | 0.5% + 2 counts |
| Indicators: | CC & CV | CC & CV | CC & CV |
| Cooling System: | thermostatic control fan | thermostatic control fan | thermostatic control fan |
| Protection Devices: | Over Voltage, Short Circuit, Over Temperature | Over Voltage, Short Circuit, Over Temperature | Over Voltage, Short Circuit, Over Temperature |
| Approvals: | CE | CE | CE |
| Dimension (WxHxD): | 8" x 4.5" x 11" | (205 x 115 x 275 mm ) | (205 x 115 x 275 mm ) |
| Weight: | 6.6lbs. | (3 Kg) | (3 Kg) |
What are the front panel controls and indicators?
- Power Switch
- DC Voltmeter (LED Display)
- DC Ammeter (LED display)
- Constant Current Mode (C.C.) Indicator
- Constant Voltage Mode (C.V.) Indicator
- Current Fine Adjust
- Current Coarse Adjust
- Voltage Fine Adjust
- Voltage Coarse Adjust
- Output Terminal Positive (+)
- Output Terminal Negative (-)
- GND Terminal
What are the rear panel controls and indicators?
- Fan
- Input Socket with fuse.
What is the function of the Power Switch?
Turns the power supply ON/OFF.
What does the DC Voltmeter (LED Display) indicate?
Indicated the present output voltage with auto range.
What does the DC Ammeter (LED display) indicate?
Indicates the present output current with auto range.
What does the Constant Current Mode (C.C.) indicator indicate?
Indicates the power supply is operating in constant current mode.
What does the Constant Voltage Mode (C.V.) indicator indicate?
Indicates the power supply is operating in voltage mode.
What is the function of the Current Fine Adjust knob?
Fine adjust knob for current limiting point and current value in constant current mode.
What is the function of the Current Coarse Adjust knob?
Coarse adjust knob for current limiting point and current value in constant current mode.
What is the function of the Voltage Fine Adjust knob?
Fine adjust knob for the output voltage in voltage mode.
What is the function of the Voltage Coarse Adjust knob?
Coarse adjust knob for the output voltage in voltage mode.
What is the Output Terminal Positive (+)?
Terminal for tapping of positive (+) output.
What is the Output Terminal Negative (-)?
Terminal for tapping of negative (-) output.
What is the GND Terminal?
Chassis ground terminal. Normally, this is connected to either the + or – terminal depending on the application.
What are the requirements for the Fan?
Allow at least 80 mm space from wall.
What is the function of the Output Voltage Control?
It is a dual control consisting of a coarse and fine potentiometer. The final DC voltage output is the sum of both adjustments.
What is the function of the Current Limiter Control?
It is a dual control (coarse/fine) that changes the DC current over the rated current range.
How to make Ground Connections?
For operating with negative or positive output terminal, grounded or without grounding. Connections (+ or -) are made by using the shorting plate at the terminal.
What should be noted when operating the supply without being grounded?
When operating this supply without being grounded, high impedance leakage can exist between the power supply circuitry and the chassis ground.
What are the Basic Modes of Operation?
This power supply is designed to operate as a constant voltage source or as a constant current source. Automatic crossover to either mode of operation occurs when load conditions change.
How does the Constant Voltage mode work?
The power supply will function as a constant voltage source as long as the load current is less than the current limiting value set by the current limit operation. When the load current is equal to or greater than the current limit set, the power supply will automatically crossover and operate as a constant source.
How does the Constant Voltage Automatic Crossover mode work?
The power supply will function as a constant source when the load voltage does not equal to the voltage value set by the output voltage control. When the load voltage equals to the value set by the output voltage control the power supply will automatically cross over and operate as a constant voltage source.
How to preset Current Limiting Value?
There are occasions when you will not want your load to draw too much current or want you want to prevent any damage, you can preset the current limiting value as follows: Short circuit the output terminals and adjust the current limit control to your desired value.
What should you do for Warranty Service?
Please return the product in the original packaging with proof of purchase to the below address. Clearly state in writing the performance problem and return any leads, connectors and accessories that you are using with the device.
What should you do for Non-Warranty Service?
Return the product in the original packaging to the below address. Clearly state in writing the performance problem and return any leads, connectors and accessories that you are using with the device. Customers not on open account must include payment in the form of a money order or credit card. For the most current repair charges contact the factory before shipping the product. Return all merchandise to B&K Precision Corp. with pre-paid shipping. The flat-rate repair charge includes return shipping to locations in North America. For overnight shipments and non-North America shipping fees contact B&K Precision Corp.