BISTOS HI-BEBE SUPER BT-150 (02) PDF MANUAL


Post questions, comments, reviews or errors in the comment box below.

Your File is Ready … Download PDF

CLICK HERE TO DOWNLOAD BISTOS HI-BEBE SUPER BT-150 (02) PDF MANUAL


PDF Content Summary: Hi-bebeSuper Application User Manual BT-150 Keep this manual for future reference P/N: 150APP-ENG-OPM-EUR-R00 BT-150 App User Manual 1 Proprietary Material Information and descriptions contained in this manual are the property of Bistos Co., Ltd. and may not be copied, reproduced, disseminated, or distributed without express written permission from Bistos Co., Ltd. Information furnished by Bistos Co., Ltd is believed to be accurate and reliable. However, no responsibility is assumed by Bistos for its use, or any infringements of patents or other rights of third parties that may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Bistos Co., Ltd. The information contained herein is subjects to change without notice. Prepared by: Bistos Co., Ltd. 7th FL., A Bldg., Woolim Lions Valley 5-cha, 302, Galmachi-ro, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Telephone: +82 31 750 0340 Fax: +82 31 750 0344 Revision R00 September, 2019 Printed in Korea Copyright © Bistos Corporation 2019. All rights reserved. P/N : 150APP-ENG-OPM-EUR-R00 Bistos Co.,Ltd. 2019.09 BT-150 App User Manual 2 Table of Contents Introduction ································································································································ 3 Getting Started ···························································································································· 3 Menu ·········································································································································· 3 P/N : 150APP-ENG-OPM-EUR-R00 Bistos Co.,Ltd. 2019.09 BT-150 App User Manual 3 1 Introduction This document describes how to use Hi bebeSuper interlocking application with the BT-150 Electric Breast Pump. - Android phone 4.4 kikat(API 19) and more - i Phone 5(iOS version 10.0) and more - However, some models may not operate normally. 2 Getting Started 2.1 Downloading the app To use the Hi bebesuper mobile app, you have to first download it from the Apple App Store or Google Play Store. Search term is “Hi bebe”. 2.2 Open the mobile app ➢ When the installation is successfully done, the icon like you can see on the left screen appears on the start menu of the smartphone. ➢ When you touched the icon, you can play the program. 3 Menu 3.1 Initial display P/N : 150APP-ENG-OPM-EUR-R00 Bistos Co.,Ltd. 2019.09 BT-150 App User Manual 4 ➢ While the app is executing, the initial screen is displayed for about 1 second. ➢ It searches the Bluetooth module around in order to wireless communication with the main unit of BT-150. ➢ It displays the found Bluetooth modules on the screen. ➢ When you choose the Bluetooth module, it tries to build the wireless communication channel with the corresponding Bluetooth module. ➢ Once connected, they are sharing the mutual information to enable the device and then it displays the main menu to the operator. ➢ On the home main menu, the user can input the information of the baby's photograph, name, date of birth and gender. Those inputs are options, so, there is no problem running the app, if you do not have to enter ➢ The main menu is division to Operation, Program, Statistics. ➢ You can control the main unit by “operation” menu. ➢ To play the stored program sequences, enter the "Program" menu. ➢ To see the history of pumping, enter "Statistics" menu. P/N : 150APP-ENG-OPM-EUR-R00 Bistos Co.,Ltd. 2019.09 BT-150 App User Manual 5 3.2 Operation menu ➢ When you touch the "Operation" of main menu, the screen switched into Operation menu. ➢ You can change the operating mode, pressure mode, pressure level and pressure cycle or check the changed status. ➢ It displays the lamp and battery information on the top of the menu. When the device is powered on, the operator can be turned it off. ➢ Able to select the pressure mode or operation mode. ➢ Set “Single” while using the device with single pumping mode. ➢ You can choose the desired pressure level. ➢ Select the massage mode or expression mode. ➢ You can set the pressure level by simple touching the (+) or (-) icon on the screen. ➢ You can set the cycle level like you did set pressure level. P/N : 150APP-ENG-OPM-EUR-R00 Bistos Co.,Ltd. 2019.09 BT-150 App User Manual 6 3.3 Program menu (1) program sequences input ➢ There is function saving and playing the program sequence in Program menu. ➢ The device can store the 8 different programs. Program IDs from 1 to 4 are provided by the default setting and unchangeable by the user. Program IDs from 5 to 8 are able to set by the user. (For details, refer to operation manual) ➢ Program IDs from 5 to 8 must be saved the sequences before playing. ➢ When the program sequence is changed on the device, it is also changed automatically in the App.. ➢ While you are editing program, the single / double pressure mode of sequences is also saved, when you try to play the program, the main unit is operated by the saved values. ➢ Program IDs from 5 to 8 are able to set by the user. ➢ If there is no saved program, it shows like the left picture. ➢ For editing the program sequences, you can enter the input by touching 1 sequence and input the operate mode, pressure level, pressure cycle and operate time. ➢ When finished the setting, touch the "OK". ➢ The Input of sequence can proceed and play in regular sequence from 1 to 8. ➢ The Input of sequences can possible the max 8 sequences. The program is able to play even if the 8 sequences are not filled. ➢ After you complete the input, touch the "SAVE" in display to send the information to the device. P/N : 150APP-ENG-OPM-EUR-R00 Bistos Co.,Ltd. 2019.09 BT-150 App User Manual 7 (2) program sequence playing & other function Select the program sequence number to be played. Touch the "Play" below on the screen.. During playing, the sequence is displayed in yellow like you can see the left picture. You can skip one program sequence by pressing the "SKIP" button. You can stop playing by pressing the "STOP" button. The last sequence of program is kept playing until stop or power off. If you press the button related to plays on the device, it applied automatically to the app. On the other hand, if you press the button related to play by the app, it applied automatically to the device. P/N : 150APP-ENG-OPM-EUR-R00 Bistos Co.,Ltd. 2019.09 BT-150 App User Manual 8 3.4 Statistics menu ➢ The statistics menu might be used to check your baby's health based on the amount of expressing and feeding milk. ➢ There is no statistical data saved for initial. ➢ Statistical data is using the amount and pumping time. ➢ Statistical data is recorded by the user, except the pumping time that it can be automatically entered. ➢ Statistical data can be displayed as a bar graph by daily, weekly and monthly units. ➢ You can input values by touching the pencil icon at the bottom of the Statistics menu. ➢ Input separately the left and right like you can see the left picture. ➢ Pumping time is automatically accounted. But if you want to input the more exact time, you can do it directly. ➢ The left picture is an example for display of statistical data. ➢ You can find the pencil icon on the bottom of the screen. ➢ Statistical data should be used only for health aid. P/N : 150APP-ENG-OPM-EUR-R00 Bistos Co.,Ltd. 2019.09 BT-150 App User Manual 9 3.5 Setting menu ➢ You can enter the “Setting” by touch the star icon. ➢ There are following choices: - Unit of statistical data - Language for Voice recognition - Voice recognition method (Online or Offline) - Display the results of voice recognition is needed - Whether you will use the voice recognition function. ➢ Detail description of voice recognition setting are following: ➢ “Offline” is a function that uses the voice recognition function equipped in the mobile device and it can be used in areas where data communication cannot be performed or performance is low. ➢ “Show” is a menu for setting whether to display the voice recognition result on the screen. ➢ “Enable” is a menu for setting whether to use the voice recognition function. You can disable the function where the difficult area of voice recognition such as a noisy place. 3.5 Voice recognition ➢ The voice recognition function provides more convenient use of the breast pump. ➢ The operation mode, pressure control, cycle control, program function, lamp and power function can be controlled by this function. ➢ Voice recognition processes commands as shown in the left picture. ➢ During the use of voice recognition, you can check the available command by touching the icon on the upper right of the home menu. ➢ Voice recognition commands list as below. P/N : 150APP-ENG-OPM-EUR-R00 Bistos Co.,Ltd. 2019.09 BT-150 App User Manual 10 ➢ Voice recognition commands list English CHANGE Change the operation mode. HIGH Increase the pressure level by one step. LOW Decrease the pressure level by one step. FAST Increase the pressure cycle by one step. SLOW Decrease the pressure cycle by one step. Number n Select the corresponding program ID n = 1 to 8. PLAY Play the sequence in the corresponding program ID. STOP Stop the playback sequence. SKIP Skip the playback sequence. POWER Power on. LAMP Turn on the feeding light or change the brightness. How to use for efficient voice recognition ➢ Use in as quiet a place as possible. ➢ Pronounce the listed commends clearly. ➢ One word at one time. ➢ Avoid conversations during voice recognition as much as possible. ➢ When you use the device first, use the device with display function of the voice recognition results. After confirming the voice recognition result, use it. P/N : 150APP-ENG-OPM-EUR-R00 Bistos Co.,Ltd. 2019.09


FREE ENGLISH PDF

OPERATING INSTRUCTIONS

USER GUIDE - USER MANUAL

OWNER GUIDE - OWNER MANUAL

REFERENCE GUIDE - REFERENCE MANUAL

INSTRUCTION GUIDE - INSTRUCTION MANUAL

Leave a Reply