BESTWAY 58392E (01) PDF MANUAL

BESTWAY 58392E (01) PDF MANUAL

Click here to download BESTWAY 58392E (01) PDF MANUAL


PDF Content Summary:

BESTWAY 58392E (01) PDF MANUAL

****** Page 1 ****** Bestway #58392E FILTER PUMP OWNER’S MANUAL bestwaycorp.com/support Visit Bestway YouTube channel YOIC taoT TO THE STORE QUESTIONS? PROBLEMS? MISSING PARTS? For FAQ, Manuals, Videos Or Spare Parts, Please Visit wwu.beetwaycorp.oorn/support 303021192470

****** Page 2 ****** WARNING IMPORTANT SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL INSTRUCTIONS WARN ING – RISK OF ELECTRIC SHOCK -The pump cannot be using while people are inside the pool WARN IN G – TO REDUCE THE RISK OF INJURY, do not permit children to use this product unless they are closely supervised at all times. WARN ING – RISK OF ELECTRIC SHOCK. Connect only to a grounding type receptacle. This product is provided with a ground-fault circuit-interrupter. If replacement of the plug is needed, use only identical replacement parts. WARNING• The unit is provided with a ground-fault circuit-interrupter (GFCI). To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset button.Power should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to the pump without the test button being pushed, a ground current is flowing, indicating the possibility of an electric shock. Do not use this pump. Disconnect the pump and have the problem corrected by a qualified service representative before using. CAUTION — To reduce the risk of electric shock the pool must be installed no closer than 6 feet (1.8 m) from any electrical outlet. Do not place portable appliances closer than 5 feet (1.5 m) from the pool. WARNING• • The pump is not intended to be bonded to the equipotential bonding grid. DO NOT BURY CORD. Locate cord to minimize abuse from lawn mowers, hedge trimmers, and other equipment. WARNING – To reduce the risk of electric shock, replace damaged cord immediately. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. WARNING – To reduce the risk of electric shock, do not use extension cord to connect unit to electric supply; provide a properly located outlet. CAUTION — This pump is for use with storable pools only. Do not use with permanently-installed pools. A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity. A permanently-installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage.

****** Page 3 ****** CAUTION – For continued protection against possible electric shock this unit is to bemounted to the base in accordance with the installation instructions. IMPORTANT- Using the pump with an unmatched electrical supply is dangerous and will result in catastrophic failure of pump. RISK OF ELECTRIC SHOCK – When working with electricity, turn the electrical power off at the circuit breaker and lock breaker door. Failure to do so will result in increased risk of shock, injury and possibly death. DO NOT REMOVE THE GROUNDING PRONG OR MODIFY THE PLUG IN ANY WAY. DO NOT USE ADAPTOR PLUGS. Consult a qualified electrician for any questions related to the validity of your plugs grounding. Handle the pump with care. Do not pull or carry the pump by the power cord. Never pull a plug from the outlet by yanking the power cord. Keep cord free from abrasions. Sharp objects, oil, moving parts, and heat should never be exposed to the filter pump. NOTE• • Please examine equipment before use. Notify Bestway at the customer service address listed on this manual for any manufacturing defect or missing parts at the time of purchase. Verify that the equipment components represent the filter pump model that you had intended to purchase. NOTE• • Place pump on a solid and level ground. Pay attention to position of pool and pump so adequate ventilation, drainage, and access for cleaning is available. Never place pump in an area that may accumulate water, or in an area where foot traffic will flow around the pool. NOTE• • Atmospheric conditions may affect the performance and life span of your filter pump. Unnecessary wear and tear may occur during periods of cold, heat and exposure to sun. Whenever possible shelter the pump from these conditions. NOTE’ Do not add chemicals in the filter pump. N OTE : Assembly and disassembly of this product should only be performed by adults. • THERMALLY PROTECTED MOTOR CSA ENCLOSURE 3 • FOR USE WITH SWIMMING POOLS ONLY. CAU TION : TO ENSURE CONTINUED PROTECTION AGAINST SHOCK HAZARD, USE ONLY IDENTICAL REPLACEMENT PARTS WHEN SERVICING. .WARNING: RISK OF ELECTRIC SHOCK. CONNECT ONLY TO A GROUNDING TYPE RECEPTACLE. CAU : THIS PUMP IS FOR USE WITH STORABLE POOLS ONLY – DO NOT USE WITH PERMANENTLY-INSTALLED POOLS. CAU TION : CONNECT ONLY TO GROUNDING TYPE RECEPTACLE PROTECTED BY A CLASS A GROUND FAULT CIRCUIT INTERRUPTER. CAU TION : FOR CONTINUED PROTECTION AGAINST POSSIBLE ELECTRIC SHOCK THIS UNIT IS -ro BE MOUNTED TO THE BASE IN ACCORDANCE WITH THE INSTALLATION INSTRUCTIONS. 3

****** Page 4 ****** .WARNING- RISK OF ELECTROCUTION 1) Connect Only To Properly Grounded Outlet. Do Not Remove Ground Pin 2) Inspect Cord Before Using — Do Not Use If Cord Is Damaged. 3) Keep Ground-Fault Circuit-Interrupter Dry And Off The Ground 4) Do Not Touch Plug With Wet Hands 5) Double Insulated When Servicing Use Only Identical Replacement Parts. 6) Read Instruction Manual Before Using. DO NOT REMOVE THIS TAG SAVE THESE INSTRUCTIONS. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. WARNING: Any changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. N : This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: —Reorient or relocate the receiving antenna. —Increase the separation between the equipment and receiver. —Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/ TV technician for help

****** Page 5 ****** P61730 P6113 P61731 P61732 P61733 58505/58095 P6019 P6517 P6029 P6029 P61730 1 P6113 P61735 P61736 —P61739 P61738US 9 P61734 2 4 5 P6029 P6005 “61730 P6113 “61731 “61732 “61733 58505/58095 “61734 “61735 “61736 P61738US “61739 P6019 P6517 P6124 P6005 P6029 P6916 P61408 P6680 “61318 p6124 2 2 1 1 1 1 1 1 2 1 1 2 2 5 2 1 2 1 136916 136124 P61408 P6680 P61318 2 2 1 1 1 1 1 1 2 1 1 2 2 4 2 2 1 2 9601 P6517 3 paole P6 08 B P6680

****** Page 6 ****** “6916 PEDESTAL FIXING Fig.l The filter pump must be vertically fixed on ground or a certain pedestal made of wood or concrete before use. There should be two holes 7mm in diameter on the pedestal, the space between which should be 256mm. Put filter pump on the pedestal and fix them together by fasten the bolts and nuts- All the pedestal parts should weigh over 18kgs at least to prevent the pump from accidental falling Operation 1) Open/unscrew the Air Purge Valves on the Filter Pump; air is released as water fills the Filter Pump. 2) When water comes out of the Air Purge Valves, close both the Air Purge Valves and wipe away any water. 3) Test the GFCI plug. 4) Start the Filter Pump by turning on the switch to the “l” position. GFCI Test RESET TEST Fig.l 2-M6 nut 2-M6 bolt RESET TEST

****** Page 7 ****** A To test the GFCI plug; insert it into a grounding type receptacle. B. Press the “RESET” button; the indicator turns red. NOTE: If the indicator light is not on, the test has failed. C. Press the “TEST” buttom The indicator turns off NOTE: If the indicator light is not off, the test has failed. D. Press the “RESET” button, the indicator light turns red, and the filter pump is ready for use. WARN ING: RISK OF ELECTRIC SHOCK. THE GFCI MUST BE TESTED BEFORE EACH USE. WARN ING: DO NOT USE THE PUMP IF THE ABOVE TEST FAILS. Please contact your local Bestway Customer Service. N OT E: Never operate pump while the connection valves are closed. NOTE: To prevent the risk of electrical shock, ensure your hands are completely dry when plugging-in the Filter Pump. IMPORTANT: DO NOT DRY RUN THE FILTER PUMP – Make sure both the pool’s Inlet and Outlet valves are fully covered by water before operating the Filter Pump. PUMP MAINTENANCE CAU T ION: you MUST ENSURE THE FILTER PUMP IS UNPLUGGED BEFORE ANY MAINTENANCE BEGINS OR SEVERE RISK OF INJURY OR DEATH EXISTS. 1) Unplug the Filter Pump. 2) Stop water flowing to the Filter Pump refer to pool’s manual. 3) Unscrew the Filter Cap Retainer and remove the Filter Cap. 4) Clean the Filter Cartridge with a garden hose. If filter cartridge remains soiled or discolored, it is necessary to replace it with a new one. 5) Insert the cleaned (or new) Filter Cartridge; ensure it is centered in the Filter Pump. 6) Check that the Filter Cap Seal is in place. 7) Replace the Filter Cap and screw the Filter Cap Retainer into position. 8) Open the Valve A and B. 9) Follow the PUMP INSTALLATION DIRECTIONS section to prepare the system for use. R TAN T: To ensure pool water stays clean, please clean the filter cartridge every day. For sanitary reasons we suggest replacing the Filter Cartridge with a new one every tivo weeks. PUMP STORAGE 1) Unplug the Filter Pump. 2) Stop water flowing into the Filter Pump and to remove the Filter Cartridge. 3) Discard the Filter Cartridge. 4) Detach all Hoses. 5) Dry all components thoroughly. 6) Store the filter pump in a dry location out of the reach of children. Storage temperature: 4-400C (39.2-1040F) 7) Drain the pool according to the Pool Owner’s Manual. Pump Warranty For information concerning pump warranty please visit our website at: bestwaycorp.com 7

****** Page 8 ****** Bestway For support please visit us at: bestwaycorp.com/support 02018 Bestway Inflatables & Material Corp. All rights reserved/Tous droits réseués/Todos los derechos resavados/AlIe Rechte vorbehalten/Tutti i diritti risen,eati Trademarks used in some countries under license to/ Marques utilisées dans certains pays sous la licence dei Marcas comerciales utilizadas en algunos paises bajo la licencia del Die Warenzeichen werden in einigen Ländern veruendet unter Lizenz der/ Marchi utilizzati in alcuni paesi concessi in licenza a Bestway Inflatables & Material Corp., No.3065 Cao An Road, Shanghai, 201812, China. Manufactured,distributed and represented in the European Union by/ Fabriqués, distribués et représentés dans Pl-Jnion Européenne par/Fabricac:lq distribuido y representado en Ia Uniön Europea por/ Hergestellt, vertrieben und in der Europäischen Union venreten von/Prodotto, distribuito e rappresentato nell’Unione Europea da Bestway (Europe) S.r.l., Via Resistenza, 5, 20098 San Giuliano Milanese (Milano), Italy Distributed in North America by/Distribués en Amérique du Nord par/Distribuido en Norteamérica por Bestway (USA) Inc., 3411 E. Harbour Drive, Phoenix, Arizona 85034, United States of America Tell1-855-838-3888 (For LI.S. and Canada) Distributed in Latin America by/Distribué en Amérique latine par/Distribuido en Latinoamérica por/Distribuido na América Latina por Bestway Central & South America Ltda, Salar Ascotan 1282, Parque Enea, Pudahuel, Santiago, Chile Distributed in Australia & New Zealand by Bestway Australia Pty Ltd, 98-104 Carnarvon Street, Silverwater, NSW 2128, Australia bestwaycorp.com Made in China / Fabriqué en Chine / Fabricado en China / Hergestellt in China / Prodotto in Cina

FREE ENGLISH PDF

OPERATING INSTRUCTIONS

USER GUIDE – USER MANUAL

OWNER GUIDE – OWNER MANUAL

REFERENCE GUIDE – REFERENCE MANUAL

INSTRUCTION GUIDE – INSTRUCTION MANUAL


BESTWAY 58392E (01) PDF MANUAL
BESTWAY 58392E (01) PDF MANUAL

Leave a comment, question, review or page error below. Account not required.

This site uses Akismet to reduce spam. Learn how your comment data is processed.

Scroll to top