Free English AXIS M7010 (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.
CLICK HERE TO DOWNLOAD AXIS M7010 (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
What hardware connectors are available on the AXIS M7010?
The AXIS M7010 includes the following connectors and hardware components:
1. Video input connectors: 16 analog composite video inputs (BNC), arranged in four groups of four inputs each.
2. LED indicators for network, status, and power monitoring.
3. Power connector: 2-pin terminal block for DC power input.
4. SD memory card slot: 4 microSD slots for local storage.
5. RS-485/RS-422 connector: 4 full-duplex terminal blocks for PTZ control.
6. Control button: Used for AVHS connection, dynamic DNS configuration, and factory default resets.
7. Network connector (PoE): 4 RJ-45 10BASE-T/100BASE-TX Ethernet connectors supporting Power over Ethernet.
What are the pin assignments and functions for the RS-485/RS-422 connector on the AXIS M7010?
The RS-485/RS-422 connector on the AXIS M7010 consists of two 2-pin terminal blocks used to control auxiliary equipment such as PTZ devices. It supports two-wire RS-485 half duplex, four-wire RS-485 full duplex, two-wire RS-422 simplex, and four-wire RS-422 full duplex point-to-point communication.
| Function | Pin | Notes |
|---|---|---|
| RS-485/RS-422 RX/TX A | 1 | (RX) For full duplex RS-485/RS-422; (RX/TX) For half duplex RS-485 |
| RS-485/RS-422 RX/TX B | 2 | |
| RS-485/RS-422 TX A | 3 | (TX) For full duplex RS-485/RS-422 |
| RS-485/RS-422 TX B | 4 |
What do the different LED indicator colors mean on the AXIS M7010?
The AXIS M7010 features three primary LED indicators: Network, Status, and Power.
| LED | Color | Indication |
|---|---|---|
| Network | Green | Steady for connection to a 100 MBit/s network. Flashes for network activity. |
| Amber | Steady for connection to a 10 MBit/s network. Flashes for network activity. | |
| Unlit | No network connection. | |
| Status | Green | Steady green for normal operation. |
| Amber | Steady during startup and when restoring settings. | |
| Red | Slow flash for failed upgrade. | |
| Power | Green | Normal operation. |
| Amber | Flashes green/amber during firmware upgrade. |
Note: The Status LED can also be configured to remain unlit during normal operation under Setup > System Options > Ports and Devices > LED, or configured to flash while an event is active.
What functions does the control button perform on the AXIS M7010?
The control button on the AXIS M7010 is used for three primary operations:
Connecting to an AXIS Video Hosting System (AVHS) service: Press and hold the button for about 1 second until the Status LED flashes green.
Connecting to AXIS Internet Dynamic DNS Service: Press and hold the button for about 3 seconds.
Resetting the product to factory default settings: Press and hold the button during power-up for about 15 seconds until the Status indicator flashes amber.
How do you safely remove an SD card from the AXIS M7010?
Before removal, the SD card must be unmounted to prevent corruption of recordings.
Step 1. Navigate to Setup > System Options > Storage > SD Card in the web configuration interface.
Step 2. Click the Unmount button.
Step 3. Once unmounted, safely remove the SD card from the slot.
How do you access the AXIS M7010 from a standard web browser?
Follow these steps to access the AXIS M7010 using a web browser:
Step 1. Start a browser such as Internet Explorer, Firefox, or Safari.
Step 2. Enter the IP address or host name of the AXIS M7010 in the browser address field. For Macintosh systems (Mac OS X), click the Bonjour tab and select the device from the drop-down list.
Step 3. Enter your user name and password. If accessing the product for the first time, you will be prompted to set the root password.
Step 4. The Live View page will load in your browser.
How do you set the root password on the AXIS M7010?
When the AXIS M7010 is accessed for the first time, the Configure Root Password dialog appears.
To set the password using an unencrypted HTTP connection, enter the password directly in the first dialog and confirm.
To configure the password over an encrypted HTTPS connection to prevent network eavesdropping:
Step 1. Click Create self-signed certificate.
Step 2. Provide the requested certificate details and click OK. The certificate is created and all subsequent communication is encrypted.
Step 3. Enter the desired password, re-enter it to confirm spelling, and click OK.
Note: The default administrator user name root is permanent. If the password is lost, the device must be reset to factory default settings.
How can the AXIS M7010 be accessed over the Internet?
To access the AXIS M7010 from the Internet, the network router must be configured to forward incoming traffic:
Step 1. Enable NAT-traversal in the device by navigating to Setup > System Options > Network > TCP/IP Advanced.
Step 2. The NAT-traversal feature attempts to automatically configure port mapping on UPnP-enabled routers.
Step 3. If UPnP is unavailable, manually configure port forwarding in your router for the HTTP port used by the device.
Step 4. You can also configure the AXIS Internet Dynamic DNS Service to assign a convenient host name.
What live view control buttons are available on the AXIS M7010 web interface?
The following controls appear on the Live View page:
Stream Profile: A drop-down menu that lets you choose between pre-programmed or customized stream profiles.
Manual Trigger: Manually triggers a preconfigured action rule directly from the interface.
Snapshot: Captures and allows you to save a still JPEG snapshot of the current video view.
Play: Connects to the AXIS M7010 and starts streaming media.
Stop: Stops the current video stream.
View Full Screen: Expands the video image to fill the entire monitor. Pressing the Escape key cancels full screen mode.
Record: Records the current stream locally to the destination defined in the AXIS Media Control panel.
What PTZ controls are available on the AXIS M7010 Live View page?
The Live View page includes several PTZ control mechanisms:
Emulate joystick mode: Click this button and click in the image to move the camera view in the direction of the mouse pointer.
Center mode: Click this button and click in the image to center the view directly on that point.
Ctrl panel: Opens the PTZ control panel providing advanced PTZ controls and user-defined buttons.
Preset selection: Select a saved PTZ preset position to move the camera to that angle.
Pan and Tilt bars: Move bars or use arrows to adjust pan and tilt positioning.
Zoom bar: Adjusts the focal length closer or farther away.
Focus bar: Adjusts manual focus, which temporarily disables autofocus.
Iris bar: Manually changes the lens opening, temporarily disabling auto iris.
What H.264 streaming methods does the AXIS M7010 support?
The AXIS M7010 supports four main H.264 delivery protocols:
Unicast RTP: Uses RTP over UDP for live unicast video. Prioritizes up-to-date video even if dropped frames occur. Supports a maximum of 20 simultaneous unicast connections.
RTP over RTSP: Tunnels RTP through RTSP, making it easy to traverse network firewalls configured for RTSP traffic.
RTP over RTSP over HTTP: Tunnels data through HTTP, useful when firewalls only permit web browsing traffic.
Multicast RTP: Transmits RTP over UDP to a multicast group. Provides optimal bandwidth efficiency when multiple clients watch simultaneously without multiplying stream data across the network.
What are the characteristics of Motion JPEG streaming on the AXIS M7010?
Motion JPEG (MJPEG) streaming generates a sequence of standard full-frame JPEG images updated continuously to create moving video. MJPEG provides high image quality and ensures access to every single frame, but requires considerably higher network bandwidth compared to H.264.
What alternative URL paths can be used to stream video from the AXIS M7010?
Clients and players can stream directly using the following paths where ip represents the IP address of the AXIS M7010:
Still JPEG image: http://ip/axis-cgi/jpg/image.cgi
Windows Media Player (Unicast RTP): axrtpu://ip/axis-media/media.amp
Windows Media Player (Unicast RTSP): axrtsp://ip/axis-media/media.amp
Windows Media Player (RTSP over HTTP): axrtsphttp://ip/axis-media/media.amp
Windows Media Player (Multicast): axrtpm://ip/axis-media/media.amp
QuickTime (RTSP media): rtsp://ip/axis-media/media.amp
QuickTime (3GP format): rtsp://ip/axis-media/media.3gp
What settings are included in the Basic Setup menu of the AXIS M7010?
Basic Setup provides essential shortcuts required prior to deploying the AXIS M7010:
1. Users: Define and manage authorized user accounts.
2. TCP/IP: Configure network addressing and subnet configurations.
3. Date and Time: Configure device system clock, time zones, and synchronization.
4. Video Stream: Configure image resolution, compression, and encoding standards.
How do Variable Bit Rate and Constant Bit Rate differ on the AXIS M7010?
Under H.264 configuration on the AXIS M7010, bit rate can be configured in two modes:
Variable Bit Rate (VBR): Dynamically adjusts the bit rate based on scene activity. High motion or complex images use more bandwidth, while static scenes reduce bandwidth consumption.
Constant Bit Rate (CBR): Fixes the maximum target bit rate to ensure predictable network consumption. During high activity, frame rate or image quality will automatically decrease to keep data within limits. Users can prioritize either frame rate or quality.
What is GOV length and how does it affect video on the AXIS M7010?
The GOV (Group of VOPs) length specifies the total number of frames between two consecutive full intra-frames (I-frames) in an H.264 stream. Increasing the GOV length reduces network bandwidth and storage consumption because P-frames and B-frames contain only motion differences. However, higher GOV lengths can degrade image recovery during transmission errors or high motion.
How do you display the current bit rate on the AXIS M7010 video stream?
Step 1. Navigate to Video > Video Stream > Overlay Settings.
Step 2. Check the Include text checkbox.
Step 3. Enter the string code #b in the text input field.
Step 4. Save settings to overlay the dynamic bit rate onto the video.
What is the Quad stream feature on the AXIS M7010?
Quad stream displays live video images from four separate analog camera channels simultaneously on a single combined screen, where each camera feed occupies one quarter of the display screen. Independent stream settings can be customized specifically for this quad display.
What de-interlacing options are available on the AXIS M7010?
Under Video > Camera Settings, the AXIS M7010 offers four de-interlacing methods for analog video signals:
None: No de-interlacing applied.
Blending: Combines fields to improve quality with low processor usage.
Adaptive Interpolation: Applies adaptive filtering across the frame to eliminate interlacing artifacts.
Motion Adaptive Interpolation: Analyzes motion in distinct regions of the image and applies specialized filters accordingly, delivering optimal video quality in most environments.
What are Offset Adjustments on the AXIS M7010?
The Offset Adjustments feature under Video > Camera Settings modifies horizontal and vertical synchronization to eliminate black borders surrounding an incoming analog video image. Caution should be used because extreme positive or negative values can cause the image signal to lose synchronization.
When should video termination be disabled on the AXIS M7010?
Video termination should be disabled in Video > Camera Settings when the video signal is connected in parallel (looped) with other hardware equipment. Failing to disable termination in parallel configurations can degrade signal strength and cause poor image quality.
How do you set up a Privacy Mask on the AXIS M7010?
A privacy mask blocks out private areas with an opaque solid color block that cannot be bypassed via software APIs.
Step 1. Navigate to Video > Privacy Mask.
Step 2. Click to add a new mask.
Step 3. Resize and position the mask over the desired area using your mouse cursor.
Step 4. Choose a color for the mask and enter a descriptive name.
Step 5. Save the configuration. Note: Masks are configured per individual channel and appear inside the Quad view, but separate masks cannot be configured directly on the quad view layout.
How do you upload and position an overlay image on the AXIS M7010?
Step 1. Go to Video > Overlay Image.
Step 2. Browse your local computer to select the graphic file (such as a corporate logo) and upload it to the device.
Step 3. Go to Video > Video Stream.
Step 4. Select the uploaded file from the Use overlay image drop-down list.
Step 5. Check Include overlay image at coordinates and specify the precise X and Y coordinates.
Step 6. Save your settings.
What viewer options can be configured for different web browsers on the AXIS M7010?
Under Live View Config > Default Viewer, you can select default viewing engines according to client browser types:
| Browser | Viewer | Description |
|---|---|---|
| Windows Internet Explorer | AMC | Recommended viewer in Internet Explorer (H.264/Motion JPEG). |
| QuickTime | H.264 video viewing. | |
| Java applet | Slower alternative requiring JVM (J2SE) 1.4.2 or higher, or JRE (J2SE) 5.0 or higher. | |
| Still image | Displays still images only; manual refresh required for updates. | |
| Other browsers | Server Push | Recommended viewer for alternative browsers (Motion JPEG). |
| QuickTime | H.264 video viewing. | |
| Java applet | Slower alternative to Server Push for Motion JPEG only. | |
| Still image | Displays still images only; click Refresh to update view. |
How do User Defined Links work on the AXIS M7010?
User Defined Links allow operators to execute custom commands, run external scripts, or open web addresses directly from the Live View page. In Live View Config, check Show custom link, provide a name, and enter the target URL.
CGI links: Execute a script in the background inside a hidden frame to trigger external devices or internal processes.
Web links: Open a regular URL target inside a separate browser window.
How do you create a PTZ Preset Position on the AXIS M7010?
Step 1. Navigate to PTZ > Preset Positions.
Step 2. Use the on-screen PTZ controls to steer the camera to the target view and adjust zoom, focus, and iris.
Step 3. Enter a descriptive title in the Current position field.
Step 4. If this position is intended to be the default resting position, check Use current position as Home.
Step 5. Click Add to store the position coordinates.
How does Return to Home functionality work on the AXIS M7010?
The AXIS M7010 can automatically return the PTZ camera to its designated Home preset position when no pan/tilt/zoom activity has occurred for a set duration. To activate this, enter the desired inactivity timeout into the Return to home when inactive field under PTZ > Preset Positions and save. Entering a value of zero disables the automatic return.
What priority levels are enforced by the PTZ Control Queue on the AXIS M7010?
When the PTZ Control Queue is enabled on the AXIS M7010, control over PTZ movements is governed by the following hierarchy:
1. Administrator: Takes immediate control regardless of queue status. Automatically removed 60 seconds after the last command.
2. Event: Triggered alarm actions take highest operational priority except when an administrator is actively steering.
3. Operator: Has higher priority than guard tours and regular viewers, but lower than administrators.
4. Guard Tour: Operates continuously until interrupted by an operator, event, or administrator, resuming when higher priority users exit.
5. Viewer: Viewers wait in line and receive 60 seconds of control before passing control to the next viewer in queue.
How do you configure Camera Tampering detection on the AXIS M7010?
Step 1. Go to Detectors > Camera Tampering.
Step 2. Set the Minimum duration value to define the time that must elapse before an alarm triggers. This avoids false alarms caused by short temporary disturbances.
Step 3. Check Alarm for dark images if alerts should trigger when lights are turned off or the lens is covered, sprayed, or unfocused.
Step 4. Click Save.
Step 5. Go to Events > Action Rules to bind the detector trigger to an alert action such as sending an email.
Why can the “While the rule is active” option not be used with camera tampering on the AXIS M7010?
The “While the rule is active” option cannot be used for camera tampering events because camera tampering does not have an active operational duration. Once triggered, it does not automatically reset to an untriggered state on its own.
How do you configure Motion Detection windows on the AXIS M7010?
The AXIS M7010 supports up to 10 Include and Exclude windows:
Step 1. Go to Detectors > Motion Detection.
Step 2. Define Include windows to target specific areas within the field of view where movement should generate alarms.
Step 3. Define Exclude windows within Include windows to ignore areas with irrelevant background motion, such as swaying trees or traffic.
Step 4. Adjust sensitivity and object size parameters as required.
Step 5. Click Save. The configured windows can now be assigned as triggers in Action Rules.
What trigger sources are available for Action Rules on the AXIS M7010?
The AXIS M7010 supports action rules based on the following trigger events:
Detectors: Motion detection and camera tampering alerts.
PTZ: Activation of pan/tilt/zoom controls or arrival at a preset position.
Storage: Storage device available, locked, or full.
System: Hardware startup or restart events.
Time: Pre-programmed schedules and recurrence cycles.
How do you set up an Action Rule to send an email upon motion detection on the AXIS M7010?
Step 1. Go to Events > Action Rules and click Add.
Step 2. Select Enable rule and type a descriptive name.
Step 3. Under Trigger, select Detectors from the drop-down list.
Step 4. Select Motion Detection from the sub-menu.
Step 5. Select a preconfigured Schedule from the Schedule drop-down menu.
Step 6. Under Type, select Send Notification.
Step 7. Choose the desired email recipient from the Recipient drop-down menu.
Step 8. Click OK to save the rule.
What types of event recipients can be configured on the AXIS M7010?
The AXIS M7010 supports multiple destination recipient types under Events > Recipients:
FTP servers: For offloading recorded video clips and still images.
HTTP servers: For pushing notification data or files.
TCP servers: Dedicated to delivering plain text notification messages.
Network shares: Storing continuous or event-based files on remote CIFS network shares.
Email: Delivering notifications and attached images directly to email inboxes.
How do you set up Continuous Recording on the AXIS M7010?
Continuous recording saves uninterrupted video streams to an SD card or network share.
Step 1. Go to Recordings > Continuous.
Step 2. Select Enabled.
Step 3. Choose the target SD card or network share from the Disk list.
Step 4. Choose the appropriate Stream profile.
Step 5. Click Save to initiate recording.
What happens if a stream profile is modified while continuous recording is active on the AXIS M7010?
If a new stream profile is chosen during active continuous recording on the AXIS M7010, the ongoing recording is stopped, saved in the recording list, and an entirely new recording begins using the new stream profile settings. Existing recordings remain intact until manually deleted or pruned by automated storage policies.
How do you search for and download recordings on the AXIS M7010?
Step 1. Navigate to Recordings > List.
Step 2. Apply search filters to narrow the list by date, time, or trigger event, and click Filter.
Step 3. Select the desired recording from the list.
Step 4. Click Play to view the recording directly, or click Download to save the recording to your computer.
Note: Multiple recordings are downloaded as a .zip file containing Matroska (.mkv) files. Downloaded recordings are timestamped with the time of download rather than recording creation.
What user access levels are supported on the AXIS M7010?
Under System Options > Security > Users, three distinct access levels can be assigned:
Viewer: Has access strictly to the Live View page.
Operator: Has full access to the Live View page and operational settings, but cannot access System Options.
Administrator: Unrestricted access to all configuration menus, system settings, and user account management.
How does IP address filtering work on the AXIS M7010?
IP Address Filtering prevents unauthorized devices from communicating with the AXIS M7010. Configured under System Options > Security > IP Address Filter, an administrator can define an Allow or Deny policy and enter up to 256 individual IP addresses or IP ranges into the filtering table.
How do you install an HTTPS certificate on the AXIS M7010?
Step 1. Navigate to System Options > Security > HTTPS.
Step 2. To create a self-signed certificate, click Create self-signed certificate and enter the required host information.
Step 3. To install a CA-signed certificate, click Create Certificate Request, submit the output file to your Certificate Authority, and once signed, click Install signed certificate to import it.
Step 4. Set the HTTPS Connection Policy for each user group to enforce encrypted browsing.
How do you configure IEEE 802.1X network authentication on the AXIS M7010?
Step 1. Obtain a CA certificate, a client certificate, and a client private key from your network administrator.
Step 2. Navigate to Setup > System Options > Security > IEEE 802.1X.
Step 3. Upload the CA certificate, client certificate, and client private key.
Step 4. Under Settings, select the appropriate EAPOL version (1 or 2).
Step 5. Enter your EAP identity and the private key password (up to 16 characters each).
Step 6. Check Enable IEEE 802.1X and click Save.
What time synchronization methods are available on the AXIS M7010?
Under System Options > Date and Time, you can set the AXIS M7010 internal clock using:
Synchronize with computer time: Manually copies the local client computer time once.
Synchronize with NTP Server: Automatically and continuously synchronizes time with a local or Internet NTP time server.
Set manually: Allows manual input of the date and time values.
How does the AXIS M7010 handle IPv4 and IPv6 network addressing?
The AXIS M7010 supports dual-stack operation where IPv4 and IPv6 can be enabled simultaneously, provided at least one remains active:
IPv4: By default, obtains an address automatically via DHCP. A static IP address, subnet mask, and default router can be manually assigned under System Options > Network > TCP/IP > Basic.
IPv6: Automatically receives network configuration from IPv6 routers on the network when enabled.
What is the ARP/Ping service behavior on the AXIS M7010?
The ARP/Ping utility allows setting an IP address by sending a ping packet with a specific packet length (408 bytes). On the AXIS M7010, the ARP/Ping service is automatically disabled two minutes after startup or immediately after an IP address is assigned. If the window expires, the device must be restarted to reactivate the two-minute setup period.
What AVHS connection modes are available on the AXIS M7010?
The AXIS Video Hosting System (AVHS) feature provides two operational modes:
One-click enabled: The user presses the AXIS M7010 physical control button for 1 second to initiate connection to an AVHS service. If registration does not occur within 24 hours, the service disconnects.
Always: The AXIS M7010 continuously attempts to connect to the AVHS server over the network without requiring physical button interaction.
Which network ports can be reconfigured on the AXIS M7010?
Under System Options > Network > TCP/IP > Advanced, administrators can change:
HTTP Port: Default is 80; can be set to any port between 1024 and 65536.
HTTPS Port: Default is 443; can be set to any port between 1024 and 65535.
RTSP Port: Default is 554; used for establishing H.264 video streams.
What is the purpose of SOCKS proxy on the AXIS M7010?
The SOCKS proxy protocol allows the AXIS M7010 to route outgoing traffic through a proxy server across corporate firewalls. This enables the device to send external notifications, email alerts, or file uploads to destinations located outside the private local network.
What SNMP versions and trap types are supported on the AXIS M7010?
The AXIS M7010 supports SNMP v1, v2c, and v3:
SNMP v1/v2c: Uses community strings (default read: public; default write: write). If HTTPS is active, v1/v2c should be disabled for security.
SNMP v3: Offers encrypted communication and password authentication; requires HTTPS to be enabled.
Traps available for transmission to network management consoles include: Cold start, Warm start, Link up, and Authentication failed.
Which SD card file system format is recommended for the AXIS M7010?
The AXIS M7010 supports both VFAT and ext4 file systems. The ext4 format is strongly recommended due to its structural resilience against file corruption in the event of sudden power cuts or unexpected card ejection. Note that accessing an ext4 card directly on a Windows PC requires a third-party ext4 driver.
How do you mount and configure a Network Share for storage on the AXIS M7010?
Step 1. Navigate to System Options > Storage > Network Share.
Step 2. In the Host field, enter the IP address, DNS name, or Bonjour name of the host server or NAS.
Step 3. Enter the shared folder name in the Share field.
Step 4. If authentication is enabled on the server, check The share requires login and enter the corresponding username and password.
Step 5. Click Connect to mount the network storage share.
What is the difference between Restart, Restore, and Default maintenance options on the AXIS M7010?
The maintenance options under System Options > Maintenance perform the following:
Restart: Reboots the device hardware without altering any software or network configurations.
Restore: Resets most configuration parameters back to factory settings while leaving critical network settings unchanged: boot protocol (DHCP/static), static IP address, default router, subnet mask, system time, and IEEE 802.1X settings.
Default: Completely erases all configured parameters, including all IP and network settings, restoring the device to its original out-of-the-box state.
How do you reset the AXIS M7010 to factory default settings using the physical control button?
Step 1. Disconnect power from the AXIS M7010.
Step 2. Press and hold the physical Control button while reconnecting the power cable.
Step 3. Continue holding down the Control button for approximately 15 seconds until the Status LED indicator flashes amber.
Step 4. Release the Control button. The reset process completes in approximately 1 minute, indicated by the Status LED turning steady green.
Step 5. The device returns to the factory default IP address 192.168.0.90, allowing you to re-assign an IP address.
What diagnostic logs and reports are generated by the AXIS M7010?
Under System Options > Support > Logs and Reports, the following tools are available:
System Log: Records internal operating system messages and events.
Access Log: Records failed device login attempts and client connection details.
Server Report: A comprehensive summary containing hardware status, network configurations, and the access log.
Parameter List: Complete listing of device internal parameters and operational values.
Connection List: Real-time display of all clients currently connected to video streams.
Crash Report: An archive containing low-level debugging details generated when investigating system errors.
How do you upgrade the firmware on the AXIS M7010?
Step 1. Save the latest firmware file locally to your management computer.
Step 2. In the web interface, open Setup > System Options > Maintenance.
Step 3. In the Upgrade Server section, click Browse and choose the downloaded firmware file.
Step 4. Click Upgrade.
Step 5. Wait 5 to 10 minutes while the installation and reboot process runs. Do not disconnect power during this procedure.
What is the emergency firmware recovery procedure for the AXIS M7010?
If a firmware upgrade is interrupted or corrupted, indicated by a flashing red Status LED, perform the following recovery procedure:
Step 1. From a command prompt on a client computer, assign a temporary ARP table entry and send a ping of 408 bytes:
On UNIX/Linux: arp -s <IP address> <serial number> temp followed by ping -s 408 <IP address>
On Windows: arp -s <IP address> <serial number> followed by ping -l 408 -t <IP address>
Step 2. If the AXIS M7010 does not reply within seconds, restart the unit and wait for a response, then stop the ping command.
Step 3. Open a browser, enter the device IP address, browse to select the firmware file, and click Load.
Step 4. Wait 1 to 10 minutes until the unit restarts and displays a steady green Status light.
What causes ARP/Ping IP address assignment to fail on the AXIS M7010?
ARP/Ping configuration fails if:
1. More than two minutes have elapsed since power was applied to the unit.
2. The ping packet size was not set to exactly 408 bytes.
3. The client computer and the AXIS M7010 are on different network subnets.
Why can the AXIS M7010 be accessed locally but not externally across the Internet?
If external access fails while local network access works:
1. The router may not support UPnP or NAT traversal may be disabled on the unit.
2. Manual port forwarding for the HTTP/HTTPS port may not be configured correctly in the firewall or router.
3. The default gateway router address specified in the AXIS M7010 network settings may be missing or incorrect.
4. An Internet firewall may be actively blocking incoming external traffic.
What should you check if no H.264 video stream is displayed on the AXIS M7010?
Follow these troubleshooting steps:
1. Open the AMC Control Panel on the client, select the H.264 tab, and click Set to default H.264 decoder.
2. Verify that RTSP is enabled under System Options > Network > TCP/IP > Advanced.
3. If streaming multicast, check with your network administrator to confirm the multicast IP addresses are valid and that network firewalls do not block UDP multicast traffic.
What causes lower frame rates than expected on the AXIS M7010?
Low frame rates can be resolved by:
1. Closing unneeded background applications on the client computer.
2. Reducing the number of concurrent viewers streaming from the encoder.
3. Ensuring sufficient network bandwidth is available.
4. Verifying in the AMC Control Panel under the H.264 tab that video processing is not set to “Decode only key frames”.
5. Decreasing the selected video resolution.
What does it mean when the Status and Network indicator LEDs flash red rapidly on the AXIS M7010?
When both the Status and Network LEDs flash red rapidly simultaneously, the AXIS M7010 has encountered a hardware failure. The unit requires repair or replacement through an authorized reseller.
Why does motion detection trigger false alarms on the AXIS M7010?
Motion detection algorithms evaluate changes in luminance (brightness) levels across pixel blocks. Sudden lighting shifts, such as headlights, shadows, or turning on lights, can be registered as physical motion. To prevent false alarms, reduce the sensitivity setting in the motion detection configuration window.
What are the general hardware specifications of the AXIS M7010?
General technical specifications for the AXIS M7010:
| Item | Specification |
|---|---|
| Casing | Standalone, rackmount, or wallmount |
| Processor and Memory | 4x ARTPEC-4, 4 x 512 MB RAM, 4x 128 MB Flash |
| Power | 8 to 20 V DC, max 28W; 4 x Power over Ethernet IEEE 802.3af Class 3, PS-P |
| Connectors | 16x analog composite video inputs (BNC), 4x 10BASE-T/100BASE-TX Ethernet, 4x RS-485/422 full duplex terminal blocks, 1x DC input terminal block |
| Local Storage | 4 x microSD/SDHC slots |
| Operating Conditions | 0 to 50 degrees Celsius (32 to 122 degrees Fahrenheit), 20 to 80% RH non-condensing |
| Dimensions (H x W x D) | 45 x 440 x 165 mm |
| Weight | 2540 g |
What video resolutions and frame rates are supported by the AXIS M7010?
The AXIS M7010 supports the following video encoding capabilities:
Video Compression: H.264 (MPEG-4 Part 10/AVC) Baseline Profile and Main Profile, alongside Motion JPEG.
Resolutions: 176×120 up to 720×576 for single channels; 176×120 up to 1536×1152 for quad view.
Frame Rates: Delivers up to 15 fps in all resolutions for both H.264 and Motion JPEG.
Streaming Capacity: Multi-stream H.264 and Motion JPEG supporting one H.264 and one JPEG stream per channel (8 streams total) in full framerate at maximum resolution.
What network protocols are supported by the AXIS M7010?
The AXIS M7010 supports an extensive suite of network protocols:
IPv4/v6, HTTP, HTTPS, QoS layer 3 DiffServ, FTP, SMTP, Bonjour, UPnP, SNMPv1/v2c/v3(MIB-II), DNS, DynDNS, NTP, RTSP, RTP, TCP, UDP, IGMP, RTCP, ICMP, DHCP, ARP, and SOCKS.
What key factors impact video streaming performance on the AXIS M7010?
Video encoding performance, bit rate, and delivery frame rates on the AXIS M7010 are influenced by:
1. Image resolution and compression settings: Lower compression levels and higher resolutions dramatically increase required bit rates.
2. Concurrent viewers: Multiple unicast H.264 or MJPEG clients directly increase network throughput demand.
3. Stream variations: Viewing multiple independent streams with different resolutions and compression simultaneously increases processor workload.
4. Concurrent encoding formats: Accessing Motion JPEG and H.264 video simultaneously increases CPU utilization.
5. Event configuration: Extensive use of complex motion detection rules and event actions consumes processor headroom.
6. Client computer capabilities: Low-performance client hardware can decrease perceived playback frame rate.
How do you resolve video and image quality problems such as dark or light images on the AXIS M7010?
If images from an analog camera appear too dark or too bright:
Step 1. Navigate to Setup > Video > Camera Settings.
Step 2. Adjust the Image Brightness slider within the range of 0 to 100.
Step 3. Adjust the Contrast slider to balance light and dark areas.
Step 4. If connected in parallel with other video equipment, verify that video termination is disabled.
Step 5. Enable Noise reduction under Image settings if analog video noise is visible.
What should you do if an SD card cannot be mounted on the AXIS M7010?
If an inserted SD card fails to mount:
Step 1. Check whether the SD card is write-protected (lock switch set to read-only).
Step 2. Navigate to System Options > Storage > SD Card.
Step 3. If the card shows as failed, click Check disk (applicable to ext4 file systems) to detect file system errors, then click Repair.
Step 4. If the error persists, format the card using the Format button, then click Mount.
How do you prevent an SD card or network share from running out of space on the AXIS M7010?
Step 1. Navigate to Setup > System Options > Storage and select the SD card or Network Share.
Step 2. Under Recording Settings, locate the automatic pruning configuration.
Step 3. Enable the Remove recordings older than option and specify a retention window in days or weeks.
Step 4. Click Save to ensure older recordings are automatically removed to free space for new footage.
How can you include the active PTZ preset position name in the video text overlay on the AXIS M7010?
Step 1. Navigate to Setup > Video > Video Stream > Overlay Settings.
Step 2. Select the Include text checkbox.
Step 3. Type the modifier #P into the overlay text field.
Step 4. Save the configuration. The video stream will now display the name of the currently targeted preset position.
How does the proportional speed feature function when using a joystick with the AXIS M7010?
Under PTZ > Advanced > Limits, the Enable proportional speed setting automatically scales the camera pan and tilt movement speed based on the current zoom level. When the camera is zoomed in close to an object, pan and tilt speeds are reduced to allow precise tracking, whereas wide-angle views allow full-speed movement.
CLICK HERE TO DOWNLOAD AXIS M7010 (01) PDF DOCUMENT