****** Page 1 ****** TAC UltraMix Programs Speed Timer LINEA TAC AMALGAMATOR Mixing Device programmable capsule mixer 01 10 sec Save 1 System Reset count down ATSDental Advanced Technology Solutions – OPERATING INSTRUCTIONS Dental Advanced Technolqy Solutions

****** Page 2 ****** OPERATING INSTRUCTIONS INTENDED USE TAC UltraMix is a universal mixer for amalgam, glass ionomer cements and other pre-dosed dental materials in capsules and syringes. The apparatus has been developed solely for use in dentistry. Liability cannot be accepted for damage resulting from misuse or failure to observe the Operating Instructions. The user is responsible for testing the TAC UltraMix for its use and suitability for the intended purposes. The intended use also includes the observation of the notes and regulations in these Operating Instructions. The TAC UltraMix has been shipped from the manufacturer in a safe and technically sound condition. The apparatus is built according to: Directive 93/42/EEC and subsequent amendments contained in according with the Directive Rule 89/336/CEE, 92/31/CEE and 98/68/CEE and the following harmonized standards have been applied: EN 61010-1 – EN61010-2-81-EN61326-1 – EN61000-3-2 EN6100-3-3 – ISO 7488 :1991 SAFETY CAUTION ! WARNING Please read these instructions carefully before you set up and start the device. As with all technical equipment, this unit will function properly and be safe to operate only if both the general safety regulations and the specific safety instructions laid out in these Operating Instructions are followed. 1. The unit must be operate accordance with the following instructions. We accept no liability for any damage arising from use of the unit for any other purpose. 2. Prior to setting-up the device, ensure that the voltage stated on the rating plate is identical to the available main voltage. Use of the device at different voltages may lead to the destruction of the unit. 3. The unit must be operated with the cover intact and closed, otherwise, there is a risk of injury. 4. The cover must not be opened until the capsule holder has come to a complete stop. 5. Only the capsule to be mixed but no other objects may be present in the space below the cover prior to initiating the mixing cycle. 6. Placement or operation of the unit on non-level surfaces is not permissible. 7. For operation of the unit, connect the main plug to an adequate electrical socket with grounded lead. If an extension cable is used, ensure that the grounded lead is not interrupted. 8. In order to prevent electrical shock hazards do not insert any objects into the unit with the exception of replacement parts properly installed in accordance with the present instructions. 9. The device should be opened and repairs be carried out only by qualified personnel. 10. Only adequately labelled original ATS DENTAL replacement parts may be used in the repair and maintenance of this unit. Any damage resulting from the use of third-pa rty replacement parts voids the liability of ATS DENTAL. 11. Do not expose the device to solvents, flammable liquids, and strong heat sources as these may damage the plastic housing. DENTAL MATERIALS USED The corresponding instructions for use of the material suppliers have to be observed. ASSUMPTION OF IMPAIRED SAFETY If it has to be assumed that safe operation is no longer possible, the power must be disconnected to avoid accidental operation. This may be the case, for example, if the apparatus is visibly damaged or no longer works correctly. A complete disconnection from the power supply is only ensured when the power cord is disconnected from the power source. REMOVAL OF TRANSIT SCREWS BEFORE USING REMOVE TRANSIT SCREW FROM UNDERSIDE OF UNIT. (Fig A) For safety during transit the amalgamator has been fitted with a transit screw prior to shipping. It is essential to remove this screw prior to using the amalgamator. a) Place the unit on its side on a soft surface b) Using the supplied 3mm allen key, turn the transit screw anti-clockwise until it is loosened. Remove screws. c) Place the amalgamator correct side up on a flat surface in a easily accessible location. SET UP Packaging part list: Electronic Control Console -Power Cord — Allen Key €—• DFU (Fig. D) 1. Connect the power cord with the socket at the rear of the apparatus and subsequently with the mains socket. (Fig. B) 2. Switch on the apparatus at the rear. (Fig. B) If the red screws have not been removed, the unit switch on, but it doesn’t work. The display writes as the follow:

****** Page 3 ****** Before using remove transit screw from underside of the unit Retirer la vis de transport située au dessous de liappareil avant l’utilisation Vor gebrauch die transportschraube auf der unterseite des gerätes entfernen 3. Raise the safety cover and place the mixing capsule in the mixing fork (Fig. C) – Insert the capsule in the right cap of plastic fork (Fig. C-1) Open the fork moving the left part (max8 mm) (Fig. C-2) Turn the capsule inside the plastic fork (Fig. C-3) – Check the capsule is clamp correctly. CONTROL PANEL FUNCTIONS TAC UltraMix 1 Programs Timer 3 LINEA TAC AMALGAMATOR programmable capsule mix 6 Save 4 01 10 sec System Reset 5 7 count down ATSDental Advanced Technolcgy Solutions 1. 2. 3. 4. 5. 6. 7. With “Programs” buttons, the operator can easily switch from O to 9 programs Set Mixing Speed (RPM) from 2000 to 6000 rpm Set Mixing Time (Sec.) from 1 to 99 Sec. Save in programs 1-9 the set Speed and Time Restore all the Programs to Default Parameters Start Mixing Graphic Display USE Working with program O In this program, the default parameters are: Time = O and Speed= O 1. Plan the wished time with the buttons Time “+” and 2. Plan the wished speed with the buttons Speed “+1′ and 3. Push the bottom “S” (Start). On display you will see the decreasing time. When the operation is finished, it will remain planed.

****** Page 4 ****** Working with programs 1-9. The machine is supplied with 9 different planed times of mixing and speed. Program 1 2 3 4 5 6 7 8 9 Speed (RPM) 4200 4200 4200 4200 5200 5200 2000 5800 6000 Time(Sec.) 6 10 7 8 10 8 15 6 5 Material IQC Valiant / Dispersalloy / IQC Palladium/ Contour Axia Glass / Amalcap/ Axia Base/ Axia Silver Memory Duralloy / Ana2000 / Permite C Astralloy PD/45 GC/Axia Glass/ Voco 3M Espe 1. Choose the Program with button “Programs”. 2. Using the default Speed and Time. icon on display is GREY. 3.Press the button “S” to start the mixing 4.Changing the values with the buttons Speed “+” and and the buttons Time “+” and the icon became BLUE. 5. Press “Save” to store the new values in the current program. The icon on Display become GREY. 6. Press the button “S” to start the mixing. 7. If you do not press button “Save”, you can mix with the new parameters (Press button “S”), but at the end the icon become GREY with the old parameters stored in the programs 8. Press the button “System Reset” for at least 5 Sec.to restore default parameters. 9.. During the mixing, you can see decreasing time. If the safety cover is opened during the mixing process, the motor and count down stops automatically. The mixing process might be finished by closing the safety cover. When you turn off the main switch, the amalgamator remains set on the last operation executed. TAC UltraMix fits capsules between 30 and 36 mm of length and with 14/18 mm of diameter. CLEANING Switch off the apparatus by disconnecting the mains cord. Clean housing, keypad and safety cover with a soft cloth and customary aldehyde- free disinfecting solution. Do not clean with highly aggressive disinfecting solutions (e.g. solutions based on orange oil or with an ethanol content of more than 50%), solvents (e.g. acetone), or pointed instruments, which may damage or scratch the plastic. Make sure that no disinfectant, other liquid or foreign object enters the apparatus. WARRANTY PERIOD / WARRANTY CONDITIONS ATS DENTAL., the Manufacturer, extends a 2 years warranty against defects in materials or workmanship to the original purchaser of this product. The Manufacturer agrees to correct any defects which develop within the warranty period, either by repair or replacement, at its option. This warranty is valid providing factory inspection indicates that any such defect developed during normal and proper use subject to the conditions below. Please fill out the warranty card and send promptly back to ATS DENTAL with proof of purchase. • • • Claims for damage in shipment should be filed promptly with the transportation company. All shipments claimed defective can only be returned to the Manufacturer with the written consent of the Manufacturer. All returned products must be accompanied by a full description of discrepancy or malfunction. Only ATS DENTAL srl authorized service personnel are allowed to carry out repairs to the unit. The Manufacturer shall be released from all obligations under this warranty if repairs or modifications are made by persons other than the Manufacturer’s own or authorized service personnel. Use only ATS DENTAL parts exclusively to replace defective components. The product warranty does not cover any damage resulting from the use of third-party replacements parts. The Manufacturer shall be released from all obligations under this warranty in the event of improper installation; damage due to casualty; or obvious misuse including but not limited to damage from liquids. The Manufacturer shall in no event be liable for any consequential damages arising from the misuse of the product. Only the above stated warranty shall be applicable, and all other warranties, expressed or implied, are hereby excluded. All correspondence concerning the product should specifv the model and serial number.

****** Page 5 ****** TECHNICAL DATA Manufacturer Model Dimensions Materials Noise 30″ ON – 180″ OFF Supply Voltage Frequency — Pistoia Italy ATS DENTAL TAC UltraMix 300x220x170 Plastic < 65 dBA AC 100/240 V 50/60 Hz Conditions of use: Temp +50 – +400 Shipping and Storage conditions: Temp +50C/+650 EEC 93/42 Manufacturer Intermittent Operations Nominal Power Class MD Console 7488 Classification Operating Mode Max Working Time Fuses 60 VA I rule 12 in Annex IX 93/42/EEC IP21 Type 2 30' c (+4r F/+1490F) RH < 20-95% non-condensing SYMBOLS MOD – COD Indicates a hazardous situation Supply Voltage Model – Code Electronic DFIJ available at atsdental.it Ground Important Information WARNING This symbol remind to consult the present Operating and Maintenance Instruction Manual. This symbol on the product or on its packaging indicates that this product may not be treated as household waste. Instead it shall be handled over the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about recycling of this product, please contact your local city office, your household waste disposal service or the shop where you purchased the product. High Voltage Inside. This equipment operates from A.C mains. Only authorized personnel to open unit. LIMITATION OF LIABILITY Except where prohibited by law, ATS DENTAL srl will not be liable for any loss or damage arising from this product, whether direct, indirect, special, incidental or consequential, regardless of the theory asserted, including warranty, contract, negligence or strict liability. Information valid as of March 20 ****** Page 6 ****** • B -BI-C Fig FIG A ****** Page 7 ****** FIG C FIG "D" DFIJ 8 ****** Page 8 ****** Model Modéle Modell Modelo Modello Serial Number Numéro de Série Seriennummer Nümero de Serie Numero di Serie Name — Nom — Name WARRANTY REGISTRATION ENREGISTREMENT GARANTIE GARANTIE REGISTRO DE LA GARANTiA – REGISTRAZIONE DELLA GARANZIA Amalgamator ULTRAMIX Teléfono – Telefono Nombre Nome Address – Adresse — Adresse City — Ville — Stadt — Ciudad Country — Pays — Land — Pais Direcciön Cittå — Paese Data Indirizzo Zip Code Phone Code Code Cödigo – CAP Date – Date Datum Fecha Telephone Telefon E-mail Address Return to — Renvoyer a – Rückkehr zum Volver a – Ritornare a – ATS DENTAL sri Via Vecchia Provinciale Lucchese, 49/F – Loc. Masotti 51030 SERRAVALLE PISTOIESE (PT) BY DENTAL SRL reserves the right to modify the present DFU without prior notice, MADE IN ITALY Via Vecchia Provinciale Lucchese, 49/F – Loc. Masotti ATSDental 51030 SERRAVALLE PISTOIESE (PT) – Italy Tel.: +39 0573 518137 – Fax: +39 0573 1711140 Advanced Technology Solutions info@atsdental.it internet: atsdental.it LINEA TAC AMALGAMATOR

FREE ENGLISH PDF

OPERATING INSTRUCTIONS

USER GUIDE – USER MANUAL

OWNER GUIDE – OWNER MANUAL

REFERENCE GUIDE – REFERENCE MANUAL

INSTRUCTION GUIDE – INSTRUCTION MANUAL



ATS DENTAL TAC ULTRAMIX (01) PDF MANUAL

Leave a comment, question, review or page error below.

This site uses Akismet to reduce spam. Learn how your comment data is processed.