****** Page 1 ****** ATLAS METAL 1 135 N.W. 159th DRIVE, MIAMI, FLORIDA 33 169 TEL 305.625.2451 TOLL FREE 800.762.7565 FAX 305.623.0475 WWW.ATLASFOODSERV.COM SALES@ATLASFOODSERV.COM COLD PAN REFRIGERATED AIR FLOW SYSTEM WCM-BT SERIES Service and Installation Manual Please read this manual completely before attempting to install or operate this equipment! Notify carrier of damage! Inspect all components immediately. See page 1. II DROP-IN COLD PAN REFRIGERATED, AIR FLOW SYSTEM SELF-CONTAINED WITH DEFROST SYSTEM Effective Date: 2019 IMPORTANT INFORMATION READ BEFORE USE

****** Page 2 ****** CONTENTS RECEIVING & INSPECTING EQUIPMENT SERIAL AND MODEL # LOCATION WCM-BT – SPECIFICATIONS, FEATURES AND ACCESSORIES ELECTRICAL CHARACTERISTICS, CUT-OUT REQUIREMENTS AND REFRIGERATION CHART INSTALLATION, OPERATION AND S/S MAINTENANCE PARTS LIST TROUBLE SHOOTING GUIDE ELECTRICAL SCHEMATICS LIMITED WARRANTY WARRANTY INFORMATION RECEIVING AND INSPECTING THE EQUIPMENT 1. VISUALLY INSPECT THE SHIPPING CRATE. DAMAGE SHOULD BE NOTED AND REPORTED TO THE DELIVERING CARRIER. 2. IF DAMAGED, OPEN AND INSPECT CONTENTS WITH CARRIER. 3. IF CRATE IS NOT DAMAGED AND THERE IS CONCEALED DAMAGE TO THE EQUIPMENT, NOTIFY THE CARRIER. NOTIFICATION MUST BE MADE VERBALLY AND IN WRITING. 4. REQUEST AN INSPECTION BY THE SHIPPING COMPANY FOR THE DAMAGED EQUIPMENT WITHIN 1 0 DAYS FROM RECEIPT OF THE EQUIPMENT 5. FREIGHT CARRIERS CAN SUPPLY THE NECESSARY FORMS ON REQUEST. 6. SAVE ALL CRATING MATERIALS UNTIL INSPECTION HAS BEEN MADE OR WAIVED. SERIAL NUMBER LOCATION THE SERIAL AND MODEL# CAN BE FOUND ON THE CONDENSING UNIT ENCLOSURE – SEE OPERATORS SIDE CONTROL PANEL WHEN CALLING ATLAS FOR PARTS AND SERVICE. ALWAYS HAVE THIS INFORMATION AVAILABLE. SERIAL MODEL INSTALLATION DATE:

****** Page 3 ****** Project: ATLAS METAL 1 135 N.W. 159th DRIVE, MIAMI, FLORIDA 33 169 TEL 305.625.2451 TOLL FREE 800.762.7565 FAX 305.623.0475 WWW.ATLASFOODSERV.COM SALES@ATLASFOODSERV.COM Item No.. Quantity: DROP-IN SERVING EQUIPMENT COLD PAN Refrigerated Air Flow System Self-Contained with Defrost System ü WCM-BT-3 o WCM-BT-4 OWCM-BT-5 üWCM-BT-6 WCM-BT-4 SPECIFICATIONS TOP: Constructed of 18 gauge, type 304 stainless steel, die stamped with a raised perimeter bead. There shall be a solid vinyl gasket under the beaded edge to form a seal to the counter top, thus preventing seepage or marring of the counter top. Embossed mounting lugs are provided along the inner surface of the top to hold a full set of removable separator channels in place. LINER: The inner liner shall be 18 gauge, type 304 stainless steel, one piece construction, all welded, ground and polished to a uniform finish. All corners are coved with a minimum 1/4″ radius. INSULATION: The pan is fully insulated with high density polystyrene, 1 ‘t thick on all sides, 2″ thick on the bottom and enclosed with a 22 gauge galvanized steel outer case. REFRIGERATION SYSTEM: The compressor housing shall be fabricated from 14 gauge galvanized and bolted to the base of the unit. A fully self-contained condensing unit is pro- vided with a hermetically sealed compressor and a thermostat control. The system is also provided with a forced air evapora- tor for even temperature throughout the pan that drains into a condensate evaporator pre-wired in the unit. Automatic defrost system is provided. The system is fully charged with CFC free refrigerant and ready to operate. NOTE: Proper ventilation must be provided in counter. ELECTRICAL: The unit will be wired for 15 amps. , 120 volt, single phase operation with an on/off thermostat switch and pilot light. A 6’ long, 3-wire cord and plug (NEMA 5-15P) will be provided. Specifications subject to change without notice. STANDARD FEATURES Forced air evaporator blower system for maximum efficiency in cooling more consistent food product temperature Automatic Defrost System Fully insulated for maximum efficiency and energy savings Factory applied gasket makes installation a snap and seals units to the counter top, thus eliminating seepage Accommodates standard 12″ X 20″ pans with the use of separator channel(s), or fractional size pans with the use of optional adapter bars I-Year Parts & Labor Warranty UL Listed ACCESSORIES 5YW 5-Year Compressor Warranty Stainless Steel adapter bars (pg Dl-51-52) Stainless Steel adapter plates (pg Dl-51-52) CP – Cover Plate with handles, S/S RS – Remote on/off switch for counter mounting * 220 Volt – 50 Cycle Compressor *Please see Operation & Installation Manual for ALL operation and maintenance details. * Units with these accessories are not currently UL listed. Dl-27

****** Page 4 ****** REMOVABLE SEPARATOR CHANNELS At LAS HE t AL 14″ 24″ MODEL WCM-BTX-5 (180.3cm) (17.78cm WCM-BTX-6 (215.2cm) (17.78cm e 1135 NW 159th Dr. Miami, FL 33169 • (800) 762-7565 Fax: (305) 623-0475 • O 8″ 20-1/8″ PLAN VIEW 16″ 10-3/ 6″ —9 B 21-1/2″ ELEVATION 4-71 ‘ EVAPORATOR 21-5 8″ END VIEW ELECTRICAL CUT-OUT SHIP WT. LBS. REMOTE LESS COMP. REFRIGERATION SHIP WT. (15.24cm 4-1/8″ (10.5cm) PAN SIZE 19-7/8″ x 39-1/4 x 14″ (50.4 X 99.6 X 35.5cm) 19-7/8″ x 53″ x 14″ (50.4 X 134.6 X 35.5cm) 19-7/8″ x 66-3/4″ x 14″ (50.4 X 169.5 X 35.5cm) 19-7/8″ x 80-1/2″ x 14″ (50.4 X 204.4 X 35.5cm) CHARACTERISTICS REQUIRED 43-1/2″ WCM-BT-3 (110.4cm) 57-1/4″ WCM-BT-4 (145.4cm) 71″ WCM-BT-5 84-3/4″ WCM-BT-6 6.8 amps. – 120V – 1/4HP 9.2 amps. – 120V – 1/3HP 9.2 amps. – 120V – 1/3HP 9.2 amps. – 120V – 1/3HP 22-1/4″ x 41-3/4″ 228 (56.5 X 106cm) (103.4kg) 22-1/4″ x 55-1/2″ 268 (56.5 X 140.9cm) (121.5kg) 22-1/4″ x 69-1/4″ 311 (56.5 X 175.8cm) (141.1kg) 22-1/4″ x 83″ 345 (56.5X210.8cm) (156.4kg) MODEL WCM-BTX-3 WCM-BTX-4 LBS. 180 222 100.6k 259 (117.4kg) 299 REFRIGERATION CHART MODEL WCM-BT-3 WCM-BT-4 WCM-BT-5 WCM-BT-6 1/4 1/3 1/3 1/3 REF. 134A 134A 134A 134A oz. 8 10 10 10 LOW 10 9 9 9 HIGH 170 190 160 125 BTU MI OA 1070 1285 1285 1285 WCM-BTX – REFRIGERATED COLD PAN WITHOUT COMPRESSOR Units include Refrigerated Cold Pan, Thermostat, Cap Tube & Drier (for hook up in field by others) Atlas Metal Industries Dl-28 COMPRESSORS FOR REMOTE INSTALLATIONS 2029-17JP – 1/4 HP for WCM-BTX-3 2029-27JL 1/3 HP for WCM-BTX-4, 5 & 6 atlasfoodserv.com 6/19-sc

****** Page 5 ****** REFRIGERATED PAN WITH EVAPORATOR BLOWER & TIMER WCMBT SERIES INSTALLATION Provide the correct counter cut-out opening (see chart below) and drop in. The vinyl gasket assures complete seating. A non-toxic silicone seal may be used between the gasket and counter top (not required). NOTE: Units are supplied with the nipple PVC and pipe connected to condensing evaporator. MODEL NUMBER WCMBT-3 WCMBT-4 WCMBT-5 WCMBT-6 CUT-OUT SIZE 22 1/4 x 41 3/4 22 1/4 x 55 1/2 22 1/4 x 69 1/4 22 1/4 x 83 The unit should be level for draining purposes. When installing unit in a counter, it is recommended that the operator side of the counter be completely open for air circulation. When this is not possible, such as in an island counter, it is recommended that two grill openings are provided approximately 18″ x 18″ of free air for intake and exhaust at the opposite ends of the counter. The unit is supplied with a power cord and NEMA plug. Refer to the data plate on the compressor housing for the amperage and voltage information. Use a licensed electrician when installing power source. OPERATION The unit should be turned on one hour before serving and turned off after completing the serving period. Ifthe compressor does not start immediately there is a chance the unit is in a defrost mode. A timer is installed to shut down the compressor for defrosting every 8 hour for 15 minutes. For maximum efficiency, empty food pans or covers must be in the openings until unit is ready for product. Do not block discharge or intake openings inside the unit. The thermostat has an off position and numbers from #1 through #7 (number 7 is the coldest). The unit should be turned off every day after used. Note: The unit should not operate 24/7. MAINTENANCE NEVER CLEAN PANS WITH A CHLORIDE BASED PRODUCT. CHLORIDES OR IMPROPER CLEANING COULD SCAR, MARK AND/OR CORRODE PANS. DO NOT USE STEEL WOOL OR ABRASIVE PRODUCTS. TO CLEAN USE SOAPY WARM WATER, RINSE THOROUGHLY TO REMOVE ALL RESIDUES. FAILURE TO MEET THESE CONDITIONS WILL VOID WARRANTY. CLEAN CONDENSER COIL REGULARLY.

****** Page 6 ****** Subsidiary of Mercury Aircraft, Inc. 1135 N.W. 159th DR., MIAMI, FL 33169 PHONE (305) 625-2451 , (800) 762-7565, FAX (305) 623-0475, E-mail: sales@atlasfoodserv.com PARTS LIST REFRIGERATED PAN WITH BLOWER & TIMER WCMBT SERIES 7 ITEM NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 12 13 14 15 16 17 18 19 8 6 PART NUMBER s80103-o 7002-0+Mode1 7020-0 2060-1 1003-0 1069-1 2029-17JP 2029-27JL 1855-0 S81857-o 2014-5 S81443-o 2013-0 1857-0 S81862-o 2119-3 2119-1 22-1399 20-3010 111-1080 111-1071 2026-0 1150 2025-0 1 10 2 3 4 5 WCMBT-5 SHOWN DESCRIPTION Se arator Channel Vin I Bead Gasket N Ion S acer Condensin Water Eva orator Power Cord with Plu Switch with Li t 1/4 H.P. Com ressor WCMBT-3 1/3 H.P. Com ressor WCMBT-4, 5, 6 Blower Housin Assembl WCMBT-3 Blower Housin Assembl WCMBT-4, 5, 6 Fan Blade ot Shown Fan Guard Fan Motor ot Shown Drain Pan WCMBT-3 ot Shown Drain Pan WCMBT-4, ot Shown Eva orator Coil WCMBT-3 ot Shown Eva orator Coil WCMBT-4, 5, 6 ot Shown Defrost Thermostat ot Shown Timer ot shown Heatin Element WCMBT-3 ot Shown Heatin Element WCMBT4, ot Shown 0.042 Ca Tube Not Shown Harness ot Shown Drier ot Shown Thermostat Not Shown REFRIGERATED PAN WITH EVAPORATOR

****** Page 7 ****** BLOWER & TIMER WCMBT SERIES INSTALLATION Provide the correct counter cut-out opening (see chart below) and drop in. The vinyl gasket assures complete seating. A non-toxic silicone seal may be used between the gasket and counter top (not required). NOTE: Units are supplied with the nipple PVC and pipe connected to condensing evaporator. MODEL NUMBER WCMBT-3 WCMBT-4 WCMBT-5 WCMBT-6 CUT-OUT SIZE 22 1/4 x 41 3/4 22 1/4 x 55 1/2 22 1 4 x 69 14 22 1/4 x 83 The unit should be level for draining purposes. When installing unit in a counter, it is recommended that the operator side of the counter be completely open for air circulation. When this is not possible, such as in an island counter, it is recommended that two grill openings are provided approximately 18″ x 18″ of free air for intake and exhaust at the opposite ends of the counter. The unit is supplied with a power cord and NEMA plug. Refer to the data plate on the compressor housing for the amperage and voltage information. Use a licensed electrician when installing power source. OPERATION The unit should be turned on one hour before serving and turned off after completing the serving period. If the compressor does not start immediately there is a chance the unit is in a defrost mode. A timer is installed to shut down the compressor for defrosting every 8 hour for 15 minutes. For maximum efficiency, empty food pans or covers must be in the openings until unit is ready for product. Do not block discharge or intake openings inside the unit. The thermostat has an off position and numbers from #1 through #7 (number 7 is the coldest). The unit should be turned off every day after used. Note: The unit should not operate 24/7. MAINTENANCE NEVER CLEAN PANS WITH A CHLORIDE BASED PRODUCT. CHLORIDES OR IMPROPER CLEANING COULD SCAR, MARK AND/OR CORRODE PANS. DO NOT USE STEEL WOOL OR ABRASIVE PRODUCTS. TO CLEAN USE SOAPY WARM WATER, RINSE THOROUGHLY TO REMOVE ALL RESIDUES. FAILURE TO MEET THESE CONDITIONS WILL VOID WARRANTY. CLEAN CONDENSER COIL REGULARLY.

****** Page 8 ****** ATLAS METAL Subsidiary of Mercury Aircraft, Inc. 1135 N.W. 159th DR., MIAMI, FL 33169 PHONE (305) 625-2451 , (800) 762-7565, FAX (305) 623-0475, E-mail: sales@atlasfoodserv.com Symptom Unit will not run Condenser runs but short cycles Condenser runs constantly. Food product not cold enough. Refrigerated Drop-In Trouble Shooting Guide Probable Cause Unit not plugged in. No power at receptacle. Thermostat and or switch not in the on position. Unit may be in a defrost cycle (if supplied) wait approximately 20 min. Call factory for service at 1-800-762-7565 Condenser coil dirty Inadequate ventilation. Call factory for service at 1-800-762-7565 Condenser coil dirty. Inadequate ventilation. Unit installed in a hot location Call factory for service at 1-800-762-7565 NOTE: WF series runs constantly. Food product must be chilled to 33-35 deg. when placed in unit. Air movement over food product. Food product not being stirred or rotated. Call factory for service at 1-800-762-7565

****** Page 9 ****** 4 YELLOW TIMER 3 4 B REVISION HISTORY WIRE NUT 01 120 V, ORANGE ORANGE RED WIRE NUT 2 UNIT FAN MOTOR 4 x 3 1 I BY MHA 2 o 3 z O BLACK-WHITE WHITE BLUE BLACK COMPRESSOR HEATER COOLER FAN MOTOR DEFROST TERMINATION THERMOSTAT CONDENSATE WCMBT-3 4-5 & 6 CUSTOMER: 1/4 1/3 60 DATE 9-17-08 REV 1 2 3 4 5 DEFROST HEATER ATLAS METAL 1135 NW 159TH DRIVE MIAMI, FLORIDA 33169 2 WCMBT SIZE: These plans are the exclusive property of Atlas Metal Industries Inc. Any unauthorized use without written consent of Atlas Metal Industries Inc., is strictly prohibited, 3 DATE: 09.17.08 DESCRIPTION ON CAD 4 WCMBT ELECTRICAL SCHEMATIC DRAWN BY: MHA CHECKED BY: NS REFERENCE: JOB WCMBT 3-4-5-6 DRAWING No. 1 SCALE: 3/4″ = 11-0″ SHEET No. 1 OF 1

****** Page 10 ****** ATLAS LIMITED WARRANTY TAL Atlas Metal Industries, Inc. warrants to the Purchaser of this product that the same shall be free from defects in the workmanship and material for a period of one year from the date of original installation of the equipment, but not to exceed eighteen (18) months after date of shipment from factory. During this period of time Atlas Metal Industries, Inc. will replace all defective parts and will pay for authorized replacement labor. Replacement and installation of such parts and labor shall be provided only upon prior written authority of Atlas Metal Industries, Inc. The Refrigeration warranty is for a twenty (20) month time period and includes supplying the compressor at a no charge basis provided the damage to the compressor was not caused by the customer or end user. Authorized replacement labor will be paid for a period of one year from date of installation. Freight costs for defective unit to and from Atlas Metal Industries, Inc. are not included, and all defective parts must be returned to the factory freight prepaid for evaluation. ALL WARRANTY LABOR MUST BE AUTHORIZED BY ATLAS METAL INDUSTRIES, INC. PRIOR TO THE ACTUAL WORK BEING DONE. This warranty does not apply to any equipment or any part thereof, which has been subjected to shipping damage, improper voltage, alteration, abuse or misuses, and does not cover loss of food, other products, or damage to property due to mechanical or electrical malfunction. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION OF THE FACE HEREOF. SELLER DISCLAIMS ANY IMPLIED WARRANTY OF MERCHANTABILITY OF THE GOODS OR THE FITNESS OF THE GOODS FOR ANY PURPOSE AND BUYER AGREES THAT THE GOODS ARE SOLD “AS IS.”

****** Page 11 ****** ATLAS METAL WARRANTY INFORMATION In order to have your invoice approved for payment by the factory, please note the followinq: An authorization number must be obtained from the factory prior to performing any warranty service. Atlas Metal will not approve excessive labor due to poor access to the unit being serviced. If design does not allow reasonable access, contact the factory. All travel time that exceeds 100 miles round trip must be authorized by the factory. Thank You: Warranty service Dept.

FREE ENGLISH PDF

OPERATING INSTRUCTIONS

USER GUIDE – USER MANUAL

OWNER GUIDE – OWNER MANUAL

REFERENCE GUIDE – REFERENCE MANUAL

INSTRUCTION GUIDE – INSTRUCTION MANUAL



ATLAS METAL WCM-BT-6 (01) PDF MANUAL

Leave a comment, question, review or page error below.

This site uses Akismet to reduce spam. Learn how your comment data is processed.