Click here to download ATEN CS1924M (02) PDF MANUAL


PDF Content Summary:

****** Page 1 ****** ATEN CS1922M I CS1924M 2/4-Port USB 3.0 4K DisplayPort MST KVMPTM Switch RS-232 Commands User Manual rvwswtEh aten.com

****** Page 2 ****** CSI 922M / CS1924M RS-232 Commands EMC Information FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT: This equipment has been tested and found to comply with the limits for a Class B digital service, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. Any changes or modifications made to this equipment may void the user’s authority to operate this equipment. This equipment generates, uses, and can radiate radio frequency energy. If not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by mrning the equipment off and on, the user is encouraged to fry to correct the Interference by one or more of the followmg measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (l) this device may not cause harmful Interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. KCC Statement 7.11+4 / a ( 7171 ) 717 RoHS This product is RoHS compliant. 2

****** Page 3 ****** CS1922M / CSI 924M RS-232 Commands RS-232 Operation Overview The CS 1922M / CSI 924M ‘s built-in bi-directional RS-232 serial interface allows system control through a high-end controller or PC. RS-232 serial operations in a CS 1922M / CS 1924M installation are managed via HyperTerminal sessions on systems that are running Windows. In order to use this feature to send commands to the CS1922M / CS1924M, you must first download and install a HyperTerminal application. For detailed instructions and information about each of the commands provided in this manual, please refer to the CS 1922M / CS 1924M user manual. Setup Install a HyperTerminal application on a computer that is not part of the installation, which will be used to control the switch via the RS-232 connection. HyperTerminal applications can be download from the Internet, and many operating systems are embedded with HyperTerminal applications. Hardware Connection Use a RJ-II to DB-9 serial adapter (LIN5-04A2-J1 IG) to connect a computer’s serial port to the serial port on the CS 1922M / CS 1924M, as shown below: 3

****** Page 4 ****** CSI 922M / CS1924M RS-232 Commands Note: The unit used in the diagram below is CS1924M, the procedure for connecting CS 1922M is identical with fewer KVM ports. RJ-I I to DB-9 Adapter RS-232 Pin Assignments Pin assignments for the CS 1922M / CS 1924M’s rear RJ-I I Serial Port that is used for connecting to a serial terminal are given in the table, below: Note: This RJ-II female connector is 4P4C. Pin 1 2 3 4 4 TXD: RXD: GND: Assignment Transmit Data Receive Data N/A Signal Ground 1 4 RJ-II Female

****** Page 5 ****** CS1922M / CSI 924M RS-232 Commands Console Login – HyperTerminal Once a physical connection from the computer to the CS 1922M / CS 1924M has been made, you can establish a HyperTerminal session using the instructions below. l. Open the HyperTerminal application, and configure the port settings for COMI port, then click 0K. ATEN CS1922M-CS1924M – HyperTerminal File Edit View Call Transfer Help COMI Properties pat Settings Qata bits: 8 Earity: Nne Stop bits: I flow control: Wore Defa•..’R’ Disconnected CAPS Capture Pr•nr echo Auto detect Auto detect NUM Bits per Second: 19200, Data Bits: 8, Parity: None, Stop bits: 1, Flow Control: None. 2. After configuring the port settings you must enable serial control on the switch by typing the command: Open + [Enter]. ATEN CS1922M-CS1924M – HyperTerminal File Edit Vie'” Call Transfer Help Welcome to ATEN CS1922M CS1924M Copyright(C) 2017 ATEN International Co., Ltd. Open_ 5

****** Page 6 ****** CSI 922M / CS1924M RS-232 Commands RS-232 Commands After you login via HyperTerminal (see page 5) use the instructions below to send RS-232 commands to control the switch from the computer. When RS-232 control is enabled via the Open + [Enter] command, the CS 1922M / CS 1924M’s front panel pushbuttons and hotkeys (excluding the mouse cursor shift and monitor layout hotkeys) will be disabled, until the serial connection is closed. For detailed information about the controls listed in this guide, please refer to the CS 1922M / CS 1924M user manual. Verification After entering a command, a verification message appears, as shown below, at the end of the command line, as follows: Response Message Command 0K Description Command or parameter is correct. Command incorrect Command or parameter is incorrect. With all commands in the sections that follow: • Each command string can be separated with a space. • The [Enter] command can be replaced with the ASCII code: Ox0DOA 6

****** Page 7 ****** CS1922M / CSI 924M RS-232 Commands Open I Close The Open and Close commands allows you to start and end the link between the computer sending RS-232 commands and the CS 1922M / CS 1924M. When the link is open, the CS 1922M / CS 1924M only accepts RS-232 commands and will not respond to front panel pushbuttons and hotkeys (excluding the mouse cursor shift and monitor layout hotkeys) — until the link is closed. The link starts with the open command and ends with the close command or after 2 mmutes if no command is sent. The default value is close. Use the Formula to set Parameters – to create a Command. Formulas: Command + [Enter] Parameters: Command open close Enter Enter Description Open RS-232 Link Command Close RS-232 Link Command Description Enter and send out command Open/Close RS-232 Link Command The available formulas for the Open/Close RS-232 Link commands are as follows: l. Command + [Enter] For example, to open the RS-232 link between the computer and CS 1922M / CS1924M, type the following: open [Enter] 2. Command + [Enter] For example, to close the RS-232 link between the computer and CS 1922M / CS1924M, type the following: close [Enter] 7

****** Page 8 ****** CSI 922M / CS1924M RS-232 Commands Switch Port The Switch Port command allows you to switch ports. The default port is 01. Use the Formula – to set Parameters to create a Command. Formula: Command + Control + [Enter] Parameters: Command sw Control ixx Enter Enter Switch Port Commands Description Switch Port Command Description Input Port Number x: 01-04 (Default: 01) Example: i02 Description Enter and send out command Some available formulas for the Switch Port commands are as follows: 1. Command + Control + [Enter] For example, to switch to port 2, type the following: sw i02 [Enter] Note: The Control command can be skipped and the default value will be used. 8

****** Page 9 ****** CS1922M / CSI 924M RS-232 Commands Set Baud Rate The Set Baud Rate command allows you to configure the baud rate setting for the serial port connection. The default baud rate is 19200. Use the Formula to set Parameters – to create a Command. Formula: Command + Control + [Enter] Parameters: Command baud Control 19200 38400 9600 Enter Enter Description Baud Rate Command Description Set baud rate to 19200 Set baud rate to 38400 Set baud rate to 9600 Description Enter and send out command Set Baud Rate Commands Some available formulas for the Set Baud Rate commands are as follows: l. Command + Control + [Enter] For example, to set the baud rate to 19200, type the following: baud 19200 [Enter] 9

****** Page 10 ****** CSI 922M / CS1924M RS-232 Commands Keyboard Language Layout The Keyboard Language Layout command allows you to change the keyboard language layout. The default language is English. Use the Formula – to set Parameters to create a Command. Formula: Command + Control + [Enter] Parameters: Command layout Control fr ge Enter Enter Description Keyboard Language Layout Command Description Change the keyboard language layout to English Change the keyboard language layout to French Change the keyboard language layout to Japanese Change the keyboard language layout to German Description Enter and send out command Keyboard Language Layout Commands Some available formulas for Keyboard Language Layout commands are as follows: 1. Command + Control + [Enter] For example, to change the keyboard language layout to Japanese, type the following: layout jp [Enter] 2. Command + Control + [Enter] For example, to change the keyboard language layout to French, type the following: layout fr [Enter] 10

****** Page 11 ****** CS1922M / CSI 924M RS-232 Commands Hotkey Setting The Hotkey Setting command allows you to change the hotkey used to invoke the HSM (Hotkey Setting Mode). The default hotkey is [Num Lock] + Use the Formula to set Parameters – to create a Command. Formulas: Command + Control + [Enter] Parameters: Command hotkey Control num f12 Enter Enter Description Hotkey Setting Command Description Change the HSM invoke key to: [Num Lock] + Change the HSM invoke key to: [Ctrl] + [Fl 2] Description Enter and send out command Hotkey Setting Commands Some available formulas for Hotkey Setting commands are as follows: l. Command + Control + [Enter] For example, to change the HSM invoke key to [Num Lock] + [-1, type the following: hotkey num [Enter] 2. Command + Control + [Enter] For example, to change the HSM invoke key to [Ctrl] + [F 12], type the following: hotkey n 2 [Enter] 11

****** Page 12 ****** CSI 922M / CS1924M RS-232 Commands Hotkey Switching The Hotkey Setting command allows you to change the hotkey used for switching. The default hotkey is [Scroll][Scroll]. Use the Formula – to set Parameters to create a Command. Formulas: Command + Control + [Enter] Parameters: Command switch Control scroll ctrl Enter Enter Description Hotkey Switching Command Description Change hotkey switching key to: [Scroll] [Scroll] Change hotkey switching key to: [Ctrl] [Ctrl] Description Enter and send out command Hotkey Switching Commands Some available formulas for Hotkey Switching commands are as follows: 1. Command + Control + [Enter] For example, to change the hotkey switching key to [Scroll Lock] [Scroll Lock], type the following: switch scroll [Enter] 2. Command + Control + [Enter] For example, to change the hotkey switching key to [Ctrl] [Ctrl], type the following: switch ctrl [Enter] 12

****** Page 13 ****** CS1922M / CSI 924M RS-232 Commands USB Reset The USB Reset command allows you to reset the USB connection. The default USB reset setting is off. Use the Formula to set Parameters – to create a Command. Formulas: Command + Control + [Enter] Parameters: Command usbreset Control on Enter Enter USB Reset Command Description USB Reset Command Description Enable USB reset connection Description Enter and send out command The available formula for the USB Reset command is as follows: l. Command + Control + [Enter] For example, to reset the USB connection, type the following: usbreset on [Enter] 13

****** Page 14 ****** CSI 922M / CS1924M RS-232 Commands Restore Default Settings The Restore Default Settings command allows you to reset all of the settings back to the default. The default setting is off. Use the Formula – to set Parameters to create a Command. Formulas: Command + Control + [Enter] Parameters: Command reset Control on Enter Enter Description Restore Default Settings Command Description Enable restore default values Description Enter and send out command Restore Default Value Command The available formula for the Restore Default Settings command is as follows: 1. Command + Control + [Enter] For example, to restore all CSI 922M / CSI 924M settings back to the default, type the following: reset on [Enter]

****** Page 15 ****** CS1922M / CSI 924M RS-232 Commands Firmware Upgrade The Firmware Upgrade command allows you to enable the firmware upgrade mode. The default setting is off. Use the Formula to set Parameters – to create a Command. Formulas: Command + Control + [Enter] Parameters: Command upgrade Control on Enter Enter Description Firmware Upgrade Command Description Enable firmware upgrade mode Description Enter and send out command Firmware Upgrade Command The available formula for the Firmware Upgrade command is as follows: l. Command + Control + [Enter] For example, to enable firmware upgrade mode, type the following: upgrade on [Enter] 15

****** Page 16 ****** CSI 922M / CS1924M RS-232 Commands KVM Status The KVMStatus command allows you to display read-only information about the switches’ current configuration status. The default setting is off. Use the Formula – to set Parameters to create a Command. Formulas: Command + Control + [Enter] Parameters: Command status Control on Enter Enter KVM Status Command Description KVM Status Command Description Enable KVM status Description Enter and send out command The available formula for the KVM Status command is as follows: l. Command + Control + [Enter] For example, to display the CS 1922M / CS 1924M’s configuration status, type the following: status on [Enter] A message similar to the one below will then appear: hotkey: [numlock]+[-] / [scrolllock],[scrolllock] os setting: pc keyboard emulation: enabled/disabled keyboard layout: English mouse emulation: enabled/disabled monitor re-detection: enabled/disabled 16

****** Page 17 ****** CS1922M / CSI 924M RS-232 Commands Display Mode The Display Mode command allows you to set the switch to use SST Mode or MST Mode to configure the monitor setup. Use the Formula to set Parameters – to create a Command. Formula: Command + Control + [Enter] Parameters: Command display Control sst mst Enter Enter Description Display Mode Command Description Set the Switch to use Single Stream Transport (SS T) mode Set the Switch to use Multi-Stream Transport (MS T) mode Description Enter and send out command Display Mode Commands Some available formulas for Change Display Mode commands are as follows: l. Command + Control + [Enter] For example, to set the switch to use SST mode, type the following: display sst [Enter] 2. Command + Control + [Enter] For example, to set the switch to use MST mode, type the following: display mst [Enter] 17

****** Page 18 ****** CSI 922M / CS1924M RS-232 Commands 18

FREE ENGLISH PDF

OPERATING INSTRUCTIONS

USER GUIDE – USER MANUAL

OWNER GUIDE – OWNER MANUAL

REFERENCE GUIDE – REFERENCE MANUAL

INSTRUCTION GUIDE – INSTRUCTION MANUAL



ATEN CS1924M (02) PDF MANUAL

Leave a comment, question, review or page error below.

This site uses Akismet to reduce spam. Learn how your comment data is processed.