ASSA ABLOY CORBIN RUSSWIN DC3220 (01) PDF MANUAL


Post questions, comments, reviews or errors in the comment box below.

Your File is Ready … Download PDF

CLICK HERE TO DOWNLOAD ASSA ABLOY CORBIN RUSSWIN DC3220 (01) PDF MANUAL


PDF Content Summary: Installation Instructions For Non-Hold Open or “A1” Hold Open Arm Options See pages 2 & 3 ® DC3200 Series Multi-Sized 1 thru 6 ASSA ABLOY Universal Door Closers Regular Arm Parallel Arm Jamb Mount DC3200 DC3210 DC3220 ADA compliant closers are: DC3200, DC3210, DC3220 RHR LHR 80-9330-3000-152 Rev. 05/12 See pages See pages 4 & 5 6 & 7 IMPORTANT: An improperly installed or incorrectly adjusted door closer may cause property damage or personal injury; and will void product warranty. To avoid personal injury, DO NOT DISASSEMBLE THIS DOOR CLOSER BODY. Door closers must be securely fastened to a properly reinforced door and frame with fasteners provided. Door closers with the “A1” HOLD OPEN ARM option are not permitted to be installed in fire door assemblies. BEFORE INSTALLING: The Americans with Disabilities Act (ADA) requires that doors having door closers have an opening force not to exceed 5 lbf. for interior doors, 8.5 lbf exterior doors. Use standard templating for regular arm and parallel arm applications. Jamb mounted applications use the template for 140° door opening to achieve the required opening force. The door closer's power size adjustment feature may require adjustment to its lowest setting to comply with ADA opening force guidelines. Size of Door & Door Closer Type of Installation Interior In-swinging Exterior Out-swinging Exterior Recommended Closer Size **Max. Opening Force lbs/f TO DETERMINE HAND OF 2 3 3 4 4 5 ' ' ' ' ' ' 4 0 6 0 6 0" " " " " " YOUR DOOR: LEFT 2 2 3 3 4 4 ' ' ' ' ' ' 4 6 0 6 0 6" " " " " " 18Regular & Top Jamb *4 2 3 3 ' ' ' ' 6 0 6 0" " " " *4 3 3 4 ' ' ' ' 0 6 0 6" " " " HAND DOOR **NOTE: These forces are for standard templating with bearing type hinges and do not account for pressure differentials and draft. 23456 14162224268Parallel Arm *3 *4 2 3 ' ' ' ' 6 0 6 0" " " " 1416222426 RIGHT 12HAND DOOR 3456 Installation Instructions Regular Arm Application CLOSER BRACKET Regular Arm DC3200 Series 1. Template Mark If top rail Door is and 2-1/2 Jamb "(64mm) (for closer or greater, bracket use and template arm bracket) FM131C provided. If top rail is 1-3/4 " (44mm) to 2-7/16 (62mm), see MOUNTING DIMENSIONS chart. *10-5/8 CL HINGE OR PIVOT (270) NOTES: Check hand of door, see page 1. Right Hand Application Shown. Left Hand Opposite. Dimensions given in inches (mm). Do Not Scale Drawing. Closer must be installed in a true horizontal plane to ensure proper closer performance. Door opening (up to 180°) is dependent upon door, frame, wall and hinge/pivot conditions permitting. 2. Install Closer Bracket 3. Mount Closer Body to Closer Bracket Pin Hole End Countersunk Hole End 2-1/4 (57.2) MOUNTING DIMENSIONS MIN. CLEARANCE REQUIRED OVER ARM BRACKET TOP RAIL A 2-1/2 " & OVER 1 " B 7/8 " DOORNHO HO (64mm) (25.4mm) (23mm) 1-3/4 " MIN. (44mm) *7-1/2 (191) 5/8 " 1-1/4 " (16mm) (32mm)* FRAME LINE B A TOP OF DOOR 1-1/2 " 1-11/16 " 4-5/16 1 (109.5) (25.4) (39mm)(43mm)1-7/8 " 2-1/16 " (48mm)(53mm)To obtain extra closing force add 3 " (77mm) to dimensions marked. This will limit degree of door opening to 110°. SEX MOUNTING SCREW SPECIFICATIONS ARM AND CLOSER BRACKET } or{Option Sex when nuts, ordered M54: furnished 3/8 (10)L DOOR NUT THICKNESS LENGTH “L” 1-3/8 " (35mm) 1-3/4 " (44mm) 1/4-20 THREAD & OVER Drill thru 9/32 (7.1) Enlarge to 3/8 (9.5) Dia. This Side Only (4 Places) 1-9/32 " (33mm) 1/4-20 oval head machine screw or 1/4-14 self-drilling screw. 1-21/32 " (42mm) 3/16 (4.8) diameter pilot hole required for Wood Applications. Pins (2) 1/4-14 x 1-1/2 OH Self-Drilling (4) ® or 1/4-20 x 3/4 OHMS w/ Sex Nuts (4) (M54 Option) 1/4-20 x 1/2 OHMS (2) ASSA ABLOY 80-9330-3000-152 Rev. 05/12 Page 2 Regular Arm Application (Continued) 4a. Attach Arm Bracket to Frame 4b. Attach Arm Bracket to Frame NON-HOLD OPEN ARM ONLY: HOLD OPEN ARM (A1 OPTION ONLY): Pivot (away from hinge) 1/4-14 x 1-1/2 OH Self-Drilling (4) Standard Position For Additional 15% Closing Force 1/4-14 x 1-1/2 OH Self-Drilling (4) Normal mounting position. Position with pivot point away from hinge.Reposition arm mounting bracket so that pivot point is toward hinge. HOLD OPEN ARM: Position so that dial screw is on Hinge UNDERSIDE of bracket DIAL SCREW FOR MAXIMUM POWERAway from hinge FOR REGULAR POWER 5a. Position Arm on Closer 5b. Position Arm on Closer NON-HOLD OPEN ARM ONLY: HOLD OPEN ARM ONLY: Main arm projects straight out at 90° angle to door. Main arm projects straight out at 90° angle to door. Remove main arm screw from elbow joint and disassemble arm. Thread the rod into the Arm Bracket as shown below. ARM BRACKET MAIN ARM MAIN ARM THREADED ROD 6a. Preload NON-HOLD OPEN and ARM Adjust ONLY: Arm Open door and slide arm rod into arm loop. Close door, swing arms so adjusting arm is 90° to frame. With 7/16 " wrench INSTALL and TIGHTEN SCREW SECURELY. MAIN ARM ® ASSA ABLOY For Adjustments See Page 8 80-9330-3000-152 Rev. 05/12 Page 3 6b. Preload and Adjust Arm HOLD OPEN ARM ONLY: While door is closed, adjust the Threaded Arm in the Arm Bracket until the bearing fits back onto the elbow joint on the Main Arm at 90° as shown below. RE-INSTALL AND TIGHTEN SCREW SECURELY. ARM ARM ROD BRACKET SCREW THREADED ARM 90° LOOP Extended Maintenance Lubricate Arm periodically shaded points with a drop or ARM two of appropriate lubricant. NOTE: When lubricating a SCREW Hold Open Arm, DO NOT use any lubricant on the Holding Surface components. 90° at Installation Instructions Parallel Arm Application Parallel Arm DC3210 Series 1. Template Mark Door and Jamb (for closer bracket and adapter plate) Use template FM131C provided or use dimensions in this template. 2-3/4 (70) * (156) 6-1/8 5/8 (16) DOOR FRAME STOP 1/4 (6.35) 1-1/2 (38.1) 5/8 (16) 2-3/4 (70) * To This obtain will limit extra degree closing of force add 3 " (77mm) to dimensions marked. door opening to 110°. ARM MOUNTING AND CLOSER SCREW BRACKETSPECIFICATIONS } or{Option Sex when nuts, ordered M54: furnished SPACER BLOCK (When required) 1 (25.4) 4-5/16 (109.5) 1/4-14 x 1-1/2 OH Self-Drilling (4) or 1/4-20 x 3/4 OHMS w/ Sex Nuts (4) (M54 Option) ® 1/4-20 x 1/2 OHMS (2) ASSA ABLOY 80-9330-3000-152 Rev. 05/12 FRAME ADAPTER PLATE L 5/8 REF. (16) DOOR TOP OF DOOR FRAME STOP CLHINGE OR PIVOT NOTES: Check hand of door, see page 1. Right Hand Application Shown. Left Hand Opposite. Dimensions given in inches (mm). Do Not Scale Drawing. Closer must be installed in a true horizontal CLOSER BRACKET * plane to ensure proper closer performance. Door opening (up to 180°) is dependent upon door, frame, wall and hinge/pivot conditions permitting. Pin Hole End Countersunk Holes 7-1/2 (191) 3/8 (10)DOOR THICKNESS SEX NUT LENGTH “L” 1/4-20 oval head machine screw or 1/4-14 self-drilling screw. 3/16 (4.8) diameter 1-3/8 " (35mm) 1/4-20 THREAD 1-3/4 " (44mm) & OVER Drill thru 9/32 (7.1) Enlarge to 3/8 (9.5) Dia. This Side Only (4 Places) 1-9/32 " (33mm) 1-21/32 " (42mm) pilot hole required for Wood Applications. 2. Install Closer Bracket 3. Mount Closer Body to Closer Bracket Holding Pins Page 4 Parallel Arm Application (Continued) 4. Mount Adapter Plate 5. Mount Arm Bracket Bracket on Jamb NON-HOLD OPEN ARM: Using holes spotted on soffit or stop in Step 1 mount adapter plate Pivot point must be AWAY from hinge bracket. edge of door. LATCHING SPEED VALVE HOLD OPEN ARM ONLY (A1 Option) 7. Connect and Position Arms Open door and slide arm rod into arm loop. door, swing arms so that they form a “V” position, as in Step 8. With 7/16 wrench, INSTALL AND TIGHTEN SCREW SECURELY. 1/4-20 x 1-1/2 OHMS (2) ® ASSA ABLOY 80-9330-3000-152 Rev. 05/12 1/4-20 x 1-1/2 OHMS (2) DIAL SCREW Install with dial screw facing down. 6. Position Arm onto Closer 5/16 Hex Head Screw & Washer Assembly Using hex wrench provided, turn closing speed and latching speed valves clockwise until completely closed. DO NOT OVER TIGHTEN. Using wrench, turn under side of spindle 45° toward the closer tube until it reaches the diamond position (fig. 2). Immediately place arm on spindle so that it is parallel to the closer body. Install and tighten arm screw and washer assembly. A WYARF OMH NIGEDE GEO FD OORCLOSER TUBE Reopen valves. CLOSING SPEED VALVE Fig. 1 Square position At rest Diamond Fig. 2 position Rotated 45° Rotate 45° HOLD OPEN ONLY Remove main arm screw from elbow joint and disassemble arm. Thread the rod into the Arm Bracket as shown below. While door is closed, adjust the Threaded Arm in the Arm Bracket until the bearing fits back onto the elbow joint on the Main Arm and forms a "V" as shown below. RE-INSTALL AND TIGHTEN SCREW SECURELY. ARM LOOP ARM ROD THREADED ARM ARM BRACKET Extended Maintenance Lubricate Arm periodically with a drop or two of appropriate lubricant. NOTE: When lubricating a Hold Open Arm, DO NOT use any lubricant on the Holding Surface components. Close " SCREW MAIN ARM 8. Power Adjustment To increase the power of the closer, re-adjust the arm so it is nearer the door. at shaded points To decrease power, re-adjust the arm so it is farther away from the door and then secure screw in arm loop (non-hold open) or elbow joint (hold open). (76) 3-0 MAX. MINIMUM POWER 1-1/2 (38) MIN. MAXIMUM POWER For Adjustments See Page 8 Page 5 Installation Instructions Jamb Mount Application Jamb Mount DC3220 Series 1. Template Mark Door and Jamb (for closer bracket and arm bracket) use dimensions in template below. CEILING LINE 1 CLOSER (25.4) BRACKETFRAME TOP OF FRAME A OPENING MAXIMUM A B HINGE 3 8-7/8 (76) CONDITION (225) 1-3/4 (44) MIN. MIN. 7-3/8 (187) FRAME STOP TOP OF DOOR 2-1/4 (57.2) MOUNTING SCREW SPECIFICATIONS ARM AND CLOSER BRACKET 1/4-20 oval head machine screw or 1/4-14 self-drilling screw. 3/16 (4.8) diameter pilot hole required for Wood Applications. or Sex nuts, Option M54, furnished when ordered 1/4-20 x 1/2 OHMS (2) 13-3/8 FRAME 110° (340) LINE 140° 180° 140° * CENTER HUNG Dimensions “A” and “B” are taken from centerline of hinge as shown and apply to pivot point of swing clear hinges. Offset and centerhung pivots. B *Must be single acting door. 2. Install Closer Bracket to Jamb Pin Hole End 11-7/8 (302) Butts, Offset Pivots, and Swing Clear 5-7/8 10-3/8 Hinges (149) (264) 4-5/16 (109.5) 1-9/16 (40) 7-3/8 (187) 11-7/8 (302) ARM BRACKET 1/2 (12.7) } { 3/8” DOOR (10) L SEX NUT THICKNESS LENGTH “L” 1-3/8 " (35mm) 1-9/32 " (33mm) 1/4-20 THREAD 1-3/4 & " OVER (44mm) 1-21/32 " (42mm) Drill thru 9/32 (7.1) Enlarge to 3/8 (9.5) Dia. This Side Only (4 Places) NOTES: Check hand of door, see page 1. Right Hand Application Shown. Left Hand Opposite. Dimensions given in inches (mm). Do Not Scale Drawing. Closer must be installed in a true horizontal plane to ensure proper closer performance. All degrees of door opening are dependent upon door, frame, wall and hinge/pivot conditions permitting. 3. Mount Closer Body to Closer Bracket 1/4-14 x 1-1/2 OH Self-Drilling (4) Countersunk Hole End Holding Pins ® ASSA ABLOY 80-9330-3000-152 Rev. 05/12 Page 6 Jamb Mount Application (continued) 4a. Attach Arm Bracket to Door NON-HOLD OPEN ARM ONLY: MAIN ARM ARM ROD SCREW ARM LOOP 4b. Attach Arm Bracket to Door HOLD OPEN ARM (A1 Option): 5a. Position Arm on Closer 6a. Preload and Adjust Arm Open door and slide arm rod into arm loop. Close door, swing arms so adjusting arm is 90° to frame. With 7/16 " wrench, INSTALL and TIGHTEN SCREW SECURELY.1/4-14 x 1-1/2 OH Self-Drilling (2) or 1/4-20 x 3/4 OHMS w/ Sex Nuts (2) (M54 Option) Pivot (away from Hinge) 1/4-14 x 1-1/2 OH Self-Drilling (2) or 1/4-20 x 3/4 OHMS w/ Sex Nuts (2) (M54 Option) Standard Position ® ASSA ABLOY 80-9330-3000-152 Rev. 05/12 For Additional 15% Closing Force Normal mounting position. Reposition arm mounting bracket so that Position with pivot point pivot point is toward hinge. away from hinge. Away from hinge FRAME STOP Hinge Install with dial screw facing down 5b. Position Arm on Closer Main arm projects straight out at 90° angle to door. Remove main arm screw from elbow joint and disassemble arm. Thread the rod into the Arm Bracket as shown below. 6b. Preload and Adjust Arm While door is closed, adjust the Threaded Arm in the Arm Bracket until the bearing fits back onto the elbow joint on the Main Arm at 90° as shown below. RE-INSTALL and TIGHTEN SCREW SECURELY. 90° DIAL SCREW FOR MAXIMUM POWER FOR REGULAR POWER NON-HOLD OPEN ARM ONLY: HOLD OPEN ARM ONLY (A1 Option): Main arm projects straight out at 90° angle to door. MAIN ARM ARM BRACKET THREADED ROD NON-HOLD OPEN ARM ONLY: HOLD OPEN ARM ONLY (A1 Option): ARM BRACKET Extended Maintenance Lubricate Arm periodically at THREADED ARM MAIN ARM 90° shaded points with a drop or two of appropriate lubricant. NOTE: When lubricating a Hold Open Arm, DO NOT SCREWuse any lubricant on the Holding Surface components. For Adjustments See Page 8 Page 7 Spring Power Adjustment Locate spring power adjuster from Illustration below DC3200 Size 1 thru 6 Adjustment See Chart All DC6200 closers are factory set at an approximate Size 3. Adjust closer as necessary for door size using this chart. Readjustment may be required to suit prevailing conditions. Size of Door Interior Exterior Swing In Exterior Swing Out (360°) No. Clockwise of Adjuster Power of Turns Full Equivalent Closer Size (Approx.) 2 ' 4 " (712) 2 ' 6 " (764) 42DC6200 SPRING POWER ADJUSTMENT CHART 2 ' 6 " (764) 3 ' 0 " (915) 833 ' 0 " (915) 3 ' 6 " (1067) 2 ' 6 " (764) 1243 ' 6 " (1067) 4 ' 0 " (1219) 3 ' 0 " (915) 16 5 CLOSING SPEED VALVE OPTION M71 DELAYED LATCHING ACTION VALVE SPEED BACKCHECK VALVE LOCATION VALVE BACKCHECK (FLAT W/ INTENSITY 5 " (127mm) TIP SCREWDRIVER Min. VALVE Shaft Length) SPRING POWER ADJUSTER (5/16 " WRENCH or SOCKET) Latching Speed Valve After closing speed has been obtained, turn latching speed valve CLOCKWISE to SLOW latching or COUNTER-CLOCKWISE to SPEED latching for last 2 to 5 of door travel. NOTE: Set combination of CLOSING and LATCHING speeds to between 3 and 7 seconds Use of door by handicapped, elderly or small children may require even greater closing time. Backcheck Intensity Valve Turn valve COUNTER-CLOCKWISE to reduce backcheck or CLOCKWISE to increase backcheck. (Backcheck should be set to give a soft cushioning action, not a sudden stop.) Page 8 Power Size Date Stamp Stamp eD la ye d C losingS peedAc tio n Option M-71 B ac kc he c k Installing Cover Full Cover (Standard) HOLD OPEN DIAL SCREW DIAL SCREW ® ASSA ABLOY Copyright© 2005, 2012 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. 80-9330-3000-152 Rev. 05/12 Slip cover over closer. Hold tightly L acthagainst closer mounting surface. Secure on each side with 6-32 x 1/4 " PBHMS screws. Closing Speed Valve (3/32 Allen Wrench Provided) To adjust speed of door closing from fully open to a position 2 " to 5 " from closed, turn Closing Speed Valve CLOCKWISE to SLOW closing, COUNTER-CLOCKWISE to SPEED closing. (3/32 Allen Wrench Provided) To Adjust Hold Open (A1 Option) Open the door to desired position and tighten the hold open screw firmly (For RH application, turn screw on underside CLOCKWISE. For LH application, turn screw COUNTER- CLOCKWISE.) Place the hold open dial over the hex head of the bracket screw so that one of the slots in the dial is " " directly over small screw hole tapped in bracket. Seat the dial tightly over the bracket. INSERT DIAL SCREW AND TIGHTEN SECURELY. Delayed Action Valve (3/32 Allen Wrench Provided) Turn valve CLOCKWISE to SLOW closing, COUNTER- CLOCKWISE to SPEED closing. Delayed action may be adjusted from 20 seconds to 90 seconds, depending on degree of door swing. Delay occurs at the beginning of the door closing cycle from fully open down to 70°, where the closing speed valve then begins its control.


FREE ENGLISH PDF

OPERATING INSTRUCTIONS

USER GUIDE - USER MANUAL

OWNER GUIDE - OWNER MANUAL

REFERENCE GUIDE - REFERENCE MANUAL

INSTRUCTION GUIDE - INSTRUCTION MANUAL

Leave a Reply