3 out of 5 stars (based on 1 review)
AQUAPRO AP10000UV (01) PDF MANUAL
Click here to download AQUAPRO AP10000UV (01) PDF MANUAL
PDF Summary:
AQUAPRO AP10000UV (01) PDF MANUAL
PRESSURE FILTER/UV Combo
instructions manual
9
UV–C Assembly
7
10
11
1
8
12
13
2
14
3
15
21
14
4
15
5
14
16
6
17
18
Globe Holder and Ballast
1
19
Globe Holder O Ring and Collar Set
2
UV-C Globe
3
20
Globe Cushion
4
Quartz Sleeve O Rings
5
Quartz Sleeve and Locking Collar
6
Backwash Rinsing Handle
7
Pressure Filter Lid
8
Hosetail Seal
9
Bottom Sponge Plate and Locking Nut
Clear Stepped Hosetail – Inlet
16
10
Black Stepped Hosetail – Outlet
Bio Media Ring (not included with AP5000UV)
17
11
Ball Valve/Stepped Hosetail – Backwash
12
Backwash Rinsing Paddles
13
Yellow Fine Biosponge
14
18 Lid Clamp
19 Lid O Ring
20 Filter Canister
21 Clamp Locking Key
Blue Coarse Biosponge
15
AP10000UV Model shown. Picture for illustration purposes only.
LImITED WARRANTY
This product comes with a warranty against defects
(Warranty). The benefits provided in this Warranty
are in addition to other rights and remedies available
to you under the Australia Consumer Law. The
Warranty is provided to the original purchaser of the
product on the following terms:
• The Warranty is given by Chemkay Pty Ltd trading
as Aquatec Equipment: Po Box 2087, Seville
Grove, WA 6112; contactable by phone (1300 552
202) or email (info@aquatecequipment.com).
• To make a claim under the Warranty you must
return the faulty product to the place of
purchase with a valid receipt or proof of
purchase.
• A Warranty claim must be made within 2 years
of the date of purchase.
• If your claim complies with the above terms and
the product is not an Exhaustable Item and no
Voiding Events have occurred, we will (at our
sole discretion):
- repair the product, if possible; or
- provide a replacement product; or
- if a replacement product is not available,
provide a refund for the purchase price paid.
• You will bear the cost associated with claiming
under the Warranty such as the cost of
transportation and delivery of the product to
and from the place of purchase.
• The product contains a UV-C globe, bio sponges
and O rings. These items are exhaustable
(Exhaustable Items) and are not covered under
the Warranty.
• The Warranty will be void if any of the following
events occur, as determined by us, at our sole
discretion (Voiding Events):
- any tampering/removal of warranty/
identification labels or electrical
components is evident;
- the defect has arisen due to: an accident,
incorrect or inadequate installation, misuse
or abuse of the product (including improper
maintenance and service), excessive wear
and tear, not following manufacturer’s
guidelines/instructions, or the product has
been used in a manner contrary to the
purpose or suitability of the product;
- the product has been modified without
our authority;
- the defect is caused by power surges/
spikes/brownouts.
• Loss of livestock, damage to property or
personal injury caused by the improper use or
abuse of the product will not be covered and
the manufacturer excludes all liability for such
events, to the extent permitted by law.
• In addition to the Warranty set out above, our
goods come with guarantees that cannot be
excluded under the Australian Consumer Law.
You are entitled to a replacement or refund for a
major failure and for compensation for any other
reasonably foreseeable loss or damage. You are
also entitled to have the goods repaired or
replaced if the goods fail to be of acceptable
quality and the failure does not amount to a
major failure.
• Warranty claims caused by installation faults
will not be covered.
• It is the customer’s responsibility to return
the faulty appliance for any warranty claim,
to Aquatec.
• For any warranty to be valid, an original proof of
purchase must be provided.
• If the pressure in the filter exceeds 4m head
pressure, warranty will be void.
• Our goods come with guarantees that cannot
be excluded under the Australian Consumer
Law. You are entitled to a replacement or refund
for a major failure and for compensation for any
other reasonably foreseeable loss or damage.
You are also entitled to have the goods repaired
or replaced if the goods fail to be of acceptable
quality and the failure does not amount to a
major failure.
Note: Please consult your retailer for quality original AQUAPRO replacement parts.
Visit http://www.aquatecequipment.com for nearest stockists. E.&O.E.
PRESSURE FILTER/UV Combo
instructions manual
MANUFACTUREd FOR
1300 552 202
Thank you for purchasing a quality AQUAPRO product,
the answers for your watergarden made easy!
AP5000UV
AP10000UV
MAXIMUM PONd SIZE - WITHOUT FISH - SHAdEd (L)
5000
10000
MAXIMUM PONd SIZE - WITH FISH - FULL SUN (L)
1500
3000
MAXIMUM FLOW (L/H)
3000
6000
VOLTS (V)
240
240
ULTRAVIOLET CLARIFIER (W)
11
11
FILTER CANISTER CAPACITY (L)
20
25
INLET/OUTLET Ø (mm)
25|32|40
25|32|40
CABLE LENGTH (m)
5
5
DESCRIPTIoN AND FEATURES
Your AQUAPRO pond filter has been manufactured
with advanced technology to provide you with the
best quality filter for your pond or water feature.
• Your AQUAPRO pressure filter has an
advanced backwash cleaning function to make
cleaning and maintenance easy.
• An ultraviolet clarifier incorporated into the
filter sterilizes the water as it passes through,
giving you crystal clear water.
• A pressure indicator lets you know when the
pressure in the filter increases, indicating that
the filter foams are getting blocked and
requires cleaning.
• A large canister and high surface area bio
media ensures maximum biological filtration.
INSTALLATIoN
1. If required, have a qualified electrician install
weatherproof power point near to the pond
or water feature, (within the cable length of
the filter).
2. Identify a suitable location for your new
pressure filter. The pressure filter can be
used in between a pump and a water feature
or waterfall. The filter can also be partially
buried to help disguise it in your garden. It is
important to return the clean filtered water
from your filter to the opposite end of your
pond to where the pump suction is located.
3. Connect antikink or poly tubing from your
pump to the inlet of your filter. Your filter has a
3 step hosetail inlet and outlet, please ensure
you use the largest size tubing possible and
cut off the hosetails smaller than the tubing
you are using. The outlet hose size should be
the same or larger than the inlet hose size.
Eg: If using 40mm hose, cut off the 25 and
32mm hosetail sections.
4. Connect tubing from the outlet of the filter
back into your pond at the opposite end to
where you are pumping from. You can have
the outlet of the filter running into a waterfall.
5. If the flow from your pump is greater than
the recommended max flow, you must
reduce the flow, or bypass some of the flow
with a Y piece. The pressure must not
exceed the 4 metre head.
6. Turn your pump on and then plug in the UV-C
unit on the filter. The UV-C unit should not be
turned on if there is no water flowing past
the UV-C globe. The ballast (black box on
cable) should be kept in a sheltered location.
7. You can help boost the biological function of
your filter with AQUAPRO Bacteria. Now sit
back, relax and enjoy a clean and healthy pond.
mAINTENANCE
disconnect power cord from the power supply
before performing maintenance. Never lift the
filter by the power cord.
The UV-C globe must be checked regularly and
should be replaced every 12 months.
To visually check the globe, look through the
clear UV-C indicator on the top of the filter and if
the light is working you will see a purple glow.
The power cord cannot be replaced. If the cord is
damaged, the filter must be discarded.
The filter must be operational 24 hours every day
for it to function effectively.
Regular backwash cleaning every two weeks is
recommended.
USING THE bACKWASH
1. Whilst the filter is still functioning, connect
tubing to the backwash outlet of the filter.
You can divert the dirty water into a garden
bed or into your drain. Turn the valve on the
backwash outlet to open.
2. Now turn the backwash arrow shaped dial on
the top of the filter to “clean” mode (the arrow
will face towards the ball value backwash
outlet). The water from the normal outlet will
now come out the backwash outlet.
3. Turn the cleaning handle anti-clockwise on
the filter several times or until the water
exiting the backwash outlet becomes clean.
This squeezes the filter sponges and cleans
them mechanically.
4. Now turn the backwash function dial on the
top of the filter back to “filter” mode and
close the valve on the backwash outlet.
5. Your filter has now been rinsed, now sit back
and enjoy your watergarden.
FULL DISASSEbLE AND RINSE
1. Turn off your pump and disconnect the power
cord from any electrical source. Undo the
threaded inlet and outlets from the filter, unclip
the lid clamp and carefully remove the lid.
2. Take care not to lose or damage the O ring
seal. Unscrew the clear locking screw at the
bottom of the filter sponge layers (or the black
base plate on AP10000UV model). Undo the
screw that holds the rod in place and remove
the base plate.
3. Now remove the foam sponge rings from
off the centre core and rinse them in
dechlorinated water or pond water. Using
dechlorinated water ensures the chlorine in
normal tap water does not kill the beneficial
bacteria living in your filter media. Be sure
to thoroughly squeeze the sponges to
remove sludge.
4. Remove the high efficiency bio media ring
(in AP10000UV Model only) from the bottom
of the filter canister and only remove any
excess brown sludge from the biospheres.
You should not remove all of this brown
matter as this is the beneficial bacteria which
is essential in the breakdown of toxic waste
from your pond.
5. Now clean out the canister of your filter and
any debris from the lid of the filter and
reassemble. First reassemble the partially
cleaned bio media ring into the canister and
then insert lid with the foam rings installed
onto the center core. The Foam rings should
alternate from Blue to Yellow.
6. Now put the lid back in place, taking care to
locate the O ring on the lid of the filter, firmly
push the lid back onto the canister. Fasten
the lid clamp in place and reconnect the inlet
and outlet.
7. Now plug the pump and filter in, turn on, and
sit back and enjoy your watergarden.
PRESSURE FILTER/UV Combo
instructions manual
REPLACING THE GLobE
1. Turn off power supply and remove plug from
power outlet. Turn off your pump.
2. Undo the 4 screws on the top of the filter
holding the UV-C Assembly in place.
3. Carefully lift up the UV-C Assembly out of
the filter lid. Take care not to impact the
quartz sleeve on anything – it will break.
4. Undo the quartz sleeve locking collar at the
top of the quartz sleeve. Take cars not to lose
the quartz sleeve o ring and collar.
5. Carefully remove the quartz sleeve from the
UV-C Assembly and place in a secure position.
6. You can now access the globe to replace it.
Pull out the old globe and discard
responsibly. Insert a new globe ensuring it is
connected securely.
7. Replace the quartz sleeve onto the UV-C
Assembly ensuring the o ring and collar is
located properly. Replace and tighten the
quartz sleeve locking collar.
8. Replace the UV-C Assembly into the top of
the filter ensuring it fits securely. Tighten
the 4 screws fixing the Assembly into the
filter lid.
9. Turn your pump back on and then reconnect
power supply and turn on your filter. You
have successfully replaced your UV-C globe.
ImPoRTANT SAFEGUARDS
To guard against injury, basic safety precautions
should be observed including, but not limited
to the following;
• do not look at an unshielded UV-C globe.
Ultra Violet light is harmful to your eyes and
may cause blindness.
• Always use a properly grounded power
supply that is connected to an RCd with a
rated residual operating current not
exceeding 30mA. As per AS/NZS
3350.2.41:1997.
• Always unplug the filter from the power
supply when not in use or before performing
any maintenance on the pump.
• Never pull the cord to disconnect the plug
from the power supply. Grasp the plug and
pull to disconnect.
• do not install or store the filter where it will
be exposed to extreme hot or cold
temperatures.
• Keep out of reach of children or pets. This
appliance should not be used by children or
infirm persons without supervision.
• do not cut the cord as this will result in
voiding your warranty.
• Care should be taken to arrange the power
cord so that it cannot be accidently tripped
over or pulled.
• do not attempt to repair the filter yourself.
Return to an authorized service centre or
place of purchase if a fault occurs (regular
maintenance is not considered repair and is
required by user).
FREE ENGLISH PDF
OPERATING INSTRUCTIONS
USER GUIDE – USER MANUAL
OWNER GUIDE – OWNER MANUAL
REFERENCE GUIDE – REFERENCE MANUAL
INSTRUCTION GUIDE – INSTRUCTION MANUAL
AQUAPRO AP10000UV (01) PDF MANUAL
AQUAPRO AP10000UV (01) PDF MANUAL