ALPINE CYCLONE POND PUMP PAL4000 (01) Image

FREE ENGLISH ALPINE CYCLONE POND PUMP PAL4000 (01) PDF DOCUMENT. FREE ENGLISH ALPINE CYCLONE POND PUMP PAL4000 (01) PDF USER GUIDE. FREE ENGLISH ALPINE CYCLONE POND PUMP PAL4000 (01) PDF USER MANUAL. FREE ENGLISH ALPINE CYCLONE POND PUMP PAL4000 (01) PDF OWNER GUIDE. FREE ENGLISH ALPINE CYCLONE POND PUMP PAL4000 (01) PDF OWNER MANUAL. FREE ENGLISH ALPINE CYCLONE POND PUMP PAL4000 (01) PDF REFERENCE GUIDE. FREE ENGLISH ALPINE CYCLONE POND PUMP PAL4000 (01) PDF INSTRUCTION GUIDE. FREE ENGLISH ALPINE CYCLONE POND PUMP PAL4000 (01) PDF REFERENCE MANUAL. FREE ENGLISH ALPINE CYCLONE POND PUMP PAL4000 (01) PDF INSTRUCTION MANUAL. FREE ENGLISH ALPINE CYCLONE POND PUMP PAL4000 (01) PDF OPERATING INSTRUCTIONS.


CLICK HERE TO DOWNLOAD ALPINE CYCLONE POND PUMP PAL4000 (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

What are the safety guidelines for using the ALPINE CYCLONE POND PUMP PAL4000?

Always follow these safety guidelines when using your pump:

WARNING: Risk of electric shock – This pump has not been approved for use in swimming pool or marine areas.

WARNING: To provide continued protection against risk of electric shock, connect to properly grounded, ground fault circuit interrupter (GFCI) outlets only, using the following guidelines:

(A) Read and follow all safety instructions and all the important notices on the appliance before using the pump. Failure to do so may result in loss of fish life and/or damage to this appliance.

(B) Have a qualified electrician install a properly grounded receptacle outlet, acceptable for outdoor use and protected from snow and rain.

(C) Any wiring of pumps should be performed by a qualified electrician to ensure code compliance and user safety.

(D) This is a pond pump. This pump has been evaluated for use with water only. Do not use this pump for other than intended use (i.e.: do not use in swimming pools, aquariums, etc. Not to be used as a sump pump.)

(E) Do not use this pump in swimming pools or other situations where people are immersed.

(F) If an extension cord is necessary, ensure connection is watertight and dust proof. A cord with proper rating should be used. A cord rated for less amps or watts than the appliance rating may overheat. Care should be taken to arrange the cord so that it will not be tripped over or pulled. The connection should be carried out by a qualified electrical installer.

(G) Unplug pump at receptacle outlet when not in use or before removal from pond.

(H) To reduce risk of electrical shock, all wiring and junction connections should be made per local codes. Requirements may vary depending on usage and location.

(I) Inspect the power cable before using. The power cable should be protected at all times to avoid punctures, cuts, bruises and abrasions. Never cut the cord.

(J) Never handle power cords with wet hands.

(K) To avoid injury, do not touch moving or hot parts.

(L) Do not use the power cable to lift the pump.


What are the specifications and performance details for the ALPINE CYCLONE POND PUMP PAL4000 and other models in the series?

ALPINE ITEM # AMPS (MIN-MAX) WATTS (MIN-MAX) MAX FLOW MAX HEIGHT OUTLET CONNECTION CORD LENGTH GPH FLOW RATE
1ft 5ft 10ft 15ft 20ft 25ft 30ft 35ft
PAL2100 1.6 192 2100 20′ 1 1/2″ 33′ 2070 1532 790
PAL3100 2.3 276 3100 21 1/2′ 1 1/2″ 33′ 3070 2251 1390 479
PAL4000 2.55 306 4000 21′ 2″ 33′ 3963 3052 2140 1229 317
PAL5200 3.55 426 5200 25′ 2″ 33′ 5184 4230 3175 2121 1067
PAL6550 3.80 456 6550 26′ 2″ 33′ 6505 5369 4132 2896 1659 422
PAL8000 4.50 540 8000 26′ 2″ 33′ 7926 6439 4954 3467 1982 494
PAL10300 8 960 10300 40′ 2 1/2″ 33′ 9885 8229 6168 4597 2756 1641 941 452

What are the initial installation requirements for the ALPINE CYCLONE POND PUMP PAL4000?

• Only operate the pump when it has water running through it. Failure to do so will overheat the pump and cause it to fail, thus voiding the warranty. DO NOT OPERATE DRY!

• If you are going to use your Cyclone pump “in-line” or “out of the water,” you must prime the pump before turning it on. Priming a pump means to feed water into the tubing both in and out of the pump, to help create a suction effect to draw the water from the source. Failure to do so may cause your pump to run dry, because of air in the system- which could cause the pump to appear not to be working and will eventually burn out the pump altogether.

• Be sure that the pre-filter cage is fully snapped shut. Failure to operate the pump without the pre-filter cage on will allow large debris to enter the pump, causing the pump to fail and voiding the warranty. To protect your fish or other pond wildlife from being sucked into the pump, it is highly recommended to not operate the pump without the pre-filter cage on.

• Do not wear loose clothing that may become entangled in the impeller or other moving parts during installation.

• Keep clear of suction and discharge openings. DO NOT insert fingers in pump with power connected.

• Do not pump hazardous materials or liquids, such as oil, saltwater or organic solvents.

• Be sure no debris will block or restrict the pre-filter cage from water entering.


How do I perform a typical pond installation for the ALPINE CYCLONE POND PUMP PAL4000?

The Cyclone pump is designed to be submerged directly into the pond or out of the pond as long as water is running through the pump. To maximize pond circulation, locate the pump as far away as possible from the location of the water entering back into the water feature. It is recommended that the pump is NOT positioned in the deepest area of the pond to protect fish by preventing the pond from completely draining in case of a leak. The pump should be placed at a maximum depth of 6.5 feet (2 meters).

Step 1: The Cyclone pump includes fittings for all water features.

Step 2: A flat rubber washer seal is included for a hand-tight and leak-free connection. Make sure the flat rubber washer is in place before installing the fitting.

Step 3: The threaded collar on all of the fittings enables the pump to be installed and removed without tools. Do not use tools to attach the fittings onto the pump discharge as this might break the fitting. Fittings need to be hand-tightened only.

Step 4: Install the right-sized Multi-Hose adapter based on the diameter of the tubing you are using.

Step 5: If using tubing with a larger diameter than the smaller fittings of the Multi-Hose Adapters, cut off the smaller section to avoid any flow restriction. This way your pump will perform at an optimal level.

Step 6: Attach the tubing to the multi-hose adapter. If the tubing is loose, use a hose clamp (not included) to secure it to the fitting.

Step 7: Connect the other end of the pump tubing to an Alpine pond filter, waterfall, or water feature.

Step 8: Place the pump into your water feature. Be sure it is fully submerged before plugging into a GFCI (ground fault circuit interrupter). Once the pump is running and water is circulating, check for any fitting or waterfall leaks where external connections are made.


What are the regular operation and maintenance procedures for the ALPINE CYCLONE POND PUMP PAL4000?

WARNING: Always unplug or disconnect all appliances in the pond from the electrical supply before installing, repairing, maintaining or handling the equipment in the water.

To avoid shortening the life of the pump, follow these simple maintenance procedures:

– Once a week, verify that the pump performance is satisfactory. If you detect a drop in pump performance (such as a decrease in water flow from the pump or to the waterfall) first clean the pump’s pre-filter cage and tubing. If the water flow is still not fully restored to its original performance, clean the impeller and internal pump body.

– The pump impeller includes a high quality ceramic shaft that provides long-lasting, reliable performance when properly maintained. However, extreme care should be taken when handling the shaft during maintenance. Avoid dropping or pressing too hard on it to avoid breakage or hairline fractures, which may cause the shaft to snap while in operation.

– This pump is suitable for use in water temperatures from 32 degrees Fahrenheit (0 degrees Celsius) to 95 degrees Fahrenheit (35 degrees Celsius).

– To keep the pump in long lasting working conditions, always replace any worn parts.


How do I clean the pre-filter cage on my ALPINE CYCLONE POND PUMP PAL4000?

Do not remove the pump’s pre-filter cage while operating the pump. Failure to operate the pump without the pre-filter cage or operating the pump with a broken cage will allow large debris to enter the pump causing damage, thus voiding the warranty.

We recommend inspecting your pump on a regular basis. If you notice the water flow rate diminish, it may be due to the pump’s pre-filter cage being blocked with debris. In many cases, the clogged filter cage can be cleaned by reaching into the pond and pulling the pump out of the water to remove the debris from the filter cage.

Important Note: Always disconnect the power before performing maintenance on the pump. Pull off any debris stuck to the pump pre-filter cage and/or use a garden hose to spray off any debris stuck to the filter cage.


How do I clean or replace the impeller on the ALPINE CYCLONE POND PUMP PAL4000?

If you have thoroughly cleaned the pre-filter cage and still have diminished flow rates, then you will need to remove and inspect the impeller and internal pump body.

Step 1: Remove the pre-filter by pulling the cage off the front of the pump.

Step 2: Remove the 4 screws securing the pump body cover to the pump body.

Step 3: Twist the pump cover to the left to remove the pump cover body.

Step 4: Pull the impeller out of the pump body.

Step 5: If your impeller and internal pump body have excessive scale build-up, clean with a mild acid, such as white vinegar or non-abrasive calcium, lime and rust remover product using a sponge or soft-bristled brush that won’t scratch the stainless steel. Removing scale build-up will allow your pump to run like new again.

Step 6: After the impeller and internal body are cleaned, place the impeller back into the pump body. Twist the impeller to either the left or right until it clicks into place.

Step 7: There are pins on the pump body that the impeller will click into. The impeller has openings on the back for the pins to click into.

Step 8: Place the pump body cover 45 degrees to the left and twist to the right to lock into place.

Step 9: Connect the pump body cover to the pump body and secure by tightening with the 4 screws.

Step 10: Connect the pre-filter cage to the pump body by sliding into place.


How should I care for my ALPINE CYCLONE POND PUMP PAL4000 during the winter?

In cold climates, it is highly recommended to store your pump inside during the coldest months of the year. You may still use your Cyclone pump during the winter time, but the Cyclone pump cannot be used in below freezing temperatures. This pump is suitable for use in water temperatures from 32 degrees Fahrenheit (0 degrees Celsius) to 95 degrees Fahrenheit (35 degrees Celsius).

Please follow the steps below:

1. Disconnect the plug cord from the power supply.

2. Disconnect the tubing connected to the fitting.

3. Clean the pump and pre-filter with fresh water and store the pump in a frost-free location.


What should I do if my ALPINE CYCLONE POND PUMP PAL4000 has reduced water flow?

A. Pump or tubing may be clogged, check area around pump to be sure there is no debris blocking water from entering into the pump.

B. It may be necessary to clean the pump pre-filter and impeller. Please refer to the maintenance instructions for cleaning procedures.

C. If none of the above solve your issue, the impeller needs to be replaced.


What should I do if my ALPINE CYCLONE POND PUMP PAL4000 hums but does not push water?

A. Pump or tubing may be clogged, check area around pump to be sure there is no debris blocking water from entering into the pump.

B. It may be necessary to clean the pump pre-filter and impeller. Please refer to the maintenance instructions for cleaning procedures.

C. Make sure the pump is receiving the correct voltage.

D. If none of the above solve your issue, the impeller needs to be replaced.


What should I do if my ALPINE CYCLONE POND PUMP PAL4000 has completely shut-off?

A. The ground-fault circuit interrupter (GFCI) may have tripped.

B. Check the temperature of the water to ensure it’s within the working temperatures.

C. It may be necessary to clean the pump pre-filter and impeller. Please refer to the maintenance instructions for cleaning procedures.

D. If none of the above solve your issue, the impeller needs to be replaced.


What should I do if my ALPINE CYCLONE POND PUMP PAL4000 turns on and off intermittently?

A. Pump or tubing may be clogged, check area around pump to be sure there is no debris blocking water from entering into the pump.

B. It may be necessary to clean the pump pre-filter and impeller. Please refer to the maintenance instructions for cleaning procedures.

C. Check the temperature of the water to ensure it’s within the working temperatures.

D. If none of the above solve your issue, the impeller needs to be replaced.


What are the replacement part numbers for the ALPINE CYCLONE POND PUMP PAL4000 and other models?

Alpine Pump SKU# Alpine Replacement Parts Description
Impeller
PAL2100 PAL2100-IMP Impeller for PAL2100
PAL3100 PAL3100-IMP Impeller for PAL3100
PAL4000 PAL4000-IMP Impeller for PAL4000
PAL5200 PAL5200-IMP Impeller for PAL5200
PAL6550 PAL6550-IMP Impeller for PAL6550
PAL8000 PAL8000-IMP Impeller for PAL8000
PAL10300 PAL10300-IMP Impeller for PAL10300
O-Rings
PAL2100 PAL2131-OR O-Ring for PAL2100
PAL3100 PAL2131-OR O-Ring for PAL3100
PAL4000 PAL4568-OR O-Ring for PAL4000
PAL5200 PAL4568-OR O-Ring for PAL5200
PAL6550 PAL4568-OR O-Ring for PAL6550
PAL8000 PAL4568-OR O-Ring for PAL8000
PAL10300 PAL10300-OR O-Ring for PAL10300
Fittings
PAL2100 RP-PAL23-FIT Fitting for PAL2100
PAL3100 RP-PAL23-FIT Fitting for PAL3100
PAL4000 RP-PAL4568-FIT Fitting for PAL4000
PAL5200 RP-PAL4568-FIT Fitting for PAL5200
PAL6550 RP-PAL4568-FIT Fitting for PAL6550
PAL8000 RP-PAL4568-FIT Fitting for PAL8000
PAL10300 PAL10300-FIT Fitting for PAL10300

CLICK HERE TO DOWNLOAD ALPINE CYCLONE POND PUMP PAL4000 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.