AIC RSC-1AT (01) Image

FREE ENGLISH AIC RSC-1AT (01) PDF DOCUMENT.
FREE ENGLISH AIC RSC-1AT (01) PDF USER GUIDE.
FREE ENGLISH AIC RSC-1AT (01) PDF USER MANUAL.
FREE ENGLISH AIC RSC-1AT (01) PDF OWNER GUIDE.
FREE ENGLISH AIC RSC-1AT (01) PDF OWNER MANUAL.
FREE ENGLISH AIC RSC-1AT (01) PDF REFERENCE GUIDE.
FREE ENGLISH AIC RSC-1AT (01) PDF INSTRUCTION GUIDE.
FREE ENGLISH AIC RSC-1AT (01) PDF REFERENCE MANUAL.
FREE ENGLISH AIC RSC-1AT (01) PDF INSTRUCTION MANUAL.
FREE ENGLISH AIC RSC-1AT (01) PDF OPERATING INSTRUCTIONS.


CLICK HERE TO DOWNLOAD AIC RSC-1AT (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

What warnings should I be aware of when using the AIC RSC-1AT?

1. A shielded-type power cord is required in order to meet FCC emission limits and also to prevent interference to the nearby radio and television reception. It is essential that only the supplied power cord be used.

2. Use only shielded cables to connect I/O devices to this equipment.

3. You are cautioned that changes or modifications not expressly approved by the party responsible for compliance could void your authority to operate the equipment.


How do I prevent static electricity damage to the AIC RSC-1AT?

You should always ground yourself to prevent static electricity.

• Firmly ground yourself at all times when installing or assembling the internal components of the server. Most of electronic components in the server are highly sensitive to electrical static discharge.

• Use a solid grounding wrist strap and distinctively place all electronic components in static-shielded devices to prevent static. Grounding wrist straps can be purchased in any electronic supply store.

• Confirm that the power source is turned off and then disconnect the power cords from your system before performing any type of installation or manual servicing. A sudden surge of power could severely damage the sensitive electronic components.

• Do not precipitously open the system’s top cover. If you must open the cover for maintenance purposes, only a trained technician should be allowed to proceed this action. Integrated circuits on computer boards are highly sensitive to static electricity. Before operating a board or integrated circuit, touch an unpainted portion of the system unit chassis for a couple of seconds to discharge any static electricity on your body.


What are the environmental requirements for installing the AIC RSC-1AT?

Place the server in a stable environment.

• Place this equipment on a stable surface when installing. A small mild drop or fall could cause fatal injury to both the equipment and the person handling the equipment.

• Please keep this equipment away from humidity to prevent vast rust and disintegration.

• Carefully and accurately mount the equipment into the rack. Uneven mechanical loading may lead to hazardous consequences.

• This equipment is to be installed for operation in an environment with maximum ambient temperature below 35°C.

• Review the environment before performing any installation or servicing. Keep the equipment away from hazardous and uneven grounds.

• This server must be installed only in Restricted Access Locations.


How should I handle the AIC RSC-1AT equipment?

Handle equipment with care.

• Do not cover the openings of the system. The openings on the system are for air convection, which intentionally protect the equipment from overheating.

• Never pour any liquid into ventilation openings of the system. This could cause catastrophic fire or electrical shock.


What are the power connection requirements for the AIC RSC-1AT?

• Ensure that the voltage of the power source is within the specification on the label when connecting the equipment to the power outlet. The current load and output power of loads must be within the specification.

• This equipment must be firmly connected to reliable grounding before usage. Pay special attention to power supplied other than direct connections, e.g. using of power strips.

• Place the power cord out of the way of foot traffic. Do not place anything over the power cord. The power cord must be rated for the product, voltage and current marked on the product’s electrical ratings label. The voltage and current rating of the cord should be greater than the voltage and current rating marked on the product.


What maintenance procedures should be followed for the AIC RSC-1AT?

Pay attention to hardware maintenance.

• If the equipment is not used for a long time, disconnect the equipment from mains to avoid being damaged by transient over-voltage.

• Module and drive bays must not be empty. They must have a dummy cover.

• Never open the equipment without professional assistance. For safety reasons, only qualified service personnel should open the equipment.

• Please disconnect this equipment from the AC outlet before cleaning. Do not use liquid or detergent for cleaning. The use of a moisture sheet or cloth is recommended for cleaning.


What situations require the AIC RSC-1AT to be checked by service personnel?

If one of the following situations arise, the equipment should be checked and tested by service personnel:

1. The power cord or plug is damaged.

2. Liquid has penetrated the equipment.

3. The equipment has been exposed to moisture.

4. The equipment does not work well or will not work according to its user manual.

5. The equipment has been dropped and/or damaged.

6. The equipment has obvious signs of breakage.


What are the cautions regarding installation location, battery replacement, and power supplies for the AIC RSC-1AT?

CAUTION: The equipment intended for installation should be placed in a Restricted Access Location.

CAUTION: There will be a risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions. After performing any installation or servicing, make sure the enclosure is correct in position before turning on the power.

CAUTION: This unit may have more than one power supply. Disconnect all power sources before maintenance to avoid electric shock.


What should I do before unpacking the AIC RSC-1AT from its shipping carton?

Before removing the subsystem from the shipping carton, visually inspect the physical condition of the shipping carton. Exterior damage to the shipping carton may indicate that the contents of the carton are damaged. If any damage is found, do not remove the components; contact the dealer where the subsystem was purchased for further instructions. Before continuing, first unpack the subsystem and verify that the number of components in the shipping carton is accurate and in good condition.


What components are included with the AIC RSC-1AT?

This product contains the components listed below. Please confirm the number and the condition of the components before installation.

• Enclosure (includes power supply, fan & hard disk drive tray)

• Power cord (vary per region)

• Slide rail x 1 set (optional)


What are the specifications of the AIC RSC-1AT rackmount chassis?

Dimensions (W x D x H) mm: 438 x 680 x 43.5
inches: 17 x 26.8 x 1.72
Industry Standard EIA-RS310D
Material SGCC
Color Front Panel: Black
Cooling Middle: 4 x 40x56mm PWM + 1 x 40x28mm hot swap fans
Power Supply Standard: 500W single PSU
Option: 650W 1+1 redundant
Expansion Slot 1 full height
Front Panel System power on/off and system reset, 2 x USB 3.0 ports
LED Indicators Power, HDD and LAN
System Board Up to 12″(W) x 13″(D) EATX MB
Drive Bays External: 2.5″ hot swap 10
Backplanes 2 x 4-port 12Gb with SFF-8643 connector support 12G + 1 x 2-port with SATA connector
Storage Temperature 0°C (32°F) ~ 50°C (122°F)
Humidity 5%~95% non-condensing
Gross Weight (w/ PSU & Rail) kgs: 21
lbs: 46.3
Packaging Dimensions (W x D x H) mm: 588 x 1050 x 263
inches: 23.1 x 41.3 x 10.4
Cubic Feet 3.93
Container Load Quantity 20′ : 165
40′ : 340
40′ H : 410
Mounting Standard: 28″ tool-less slide rail

What are the main features of the AIC RSC-1AT?

• Tool-less design supports quick installation and easy maintenance:
– Tool-less 2.5″ drive trays
– Tool-less slide rail

• Supports 8 x 12G 2.5” hot swap drive bays+ 2 x 6G 2.5″ hotswap drive bays

• Supports single and redundant power supplies

• Supports 1 full height expansion slot

• Two front access USB 3.0 ports


What are the system switches and LED indicators on the front panel of the AIC RSC-1AT?

The front panel of the AIC RSC-1AT contains 10 x 2.5″ HDD trays and the following system switches and LED indicators:

• Power On/Off

• System Reset

• Power System LED

• System HDD Activity LED

• LAN 1 LED

• LAN 2 LED


What components are on the rear panel of the AIC RSC-1AT?

The rear panel of the AIC RSC-1AT features:

• 500W power supply unit (with an option for a 650W 1+1 redundant unit)

• 1 full height PCIe slot


What is the internal layout of the AIC RSC-1AT as seen from the top view?

The top view of the AIC RSC-1AT shows the internal layout which includes:

• A 500W single power supply unit (or an optional 650W 1+1 redundant power supply unit).

• A bank of fans, including 1x 4028 hotswap fan and 4x 4056 PWM fans.

• Space for a motherboard (Note: Motherboard is not included with this product).


How do I remove the top cover of the AIC RSC-1AT?

1. Push the release button on both sides of the top cover and push it toward the rear panel.

2. Lift the top cover to complete removal.


How do I replace a Power Supply Unit (PSU) module in the AIC RSC-1AT?

1. Extract the power supply unit by pushing the ejector while pulling the power supply unit.

2. Pull the module completely out of the chassis.

3. Install the new power supply unit by pushing it into the chassis. Ensure that the module is accurately inserted and locked into the chassis.


How do I replace a fan module in the AIC RSC-1AT?

1. Unplug the cables and connectors.

2. Lift the fan module upward. Check to carefully dislodge the rubber connectors from the attached bracket.

3. Insert the new fan into the chassis. Verify to align the rubber connectors with the appropriate slot in the bracket.


How do I remove and install a Hard Disk Drive (HDD) in the AIC RSC-1AT?

To remove an HDD:

1. Press the release button on the tray lever to loosen the lever.

2. Pull the tray lever outward completely.

3. Pull the tray out of the chassis.

To install an HDD:

1. Match the dimples on the tray to insert the HDD into the tray.

2. The HDD should be exactly inserted into the tray as demonstrated in the manual’s diagrams.

3. To remove the HDD from the tray, pull upward. Make certain that the HDD is not damaged during the installation or removal process.


How do I install a PCIe card using the riser card bracket in the AIC RSC-1AT?

1. Loosen the thumb screw on the riser card bracket.

2. Pull the riser card bracket out of the chassis.

3. Insert the PCIe card into the riser card bracket.

4. Install the bracket with the PCIe card into the chassis.


How do I install the AIC RSC-1AT chassis into a rack using the slide rails?

NOTE: This section provides a basic instruction for mounting the slide rail onto the system. Tool-less rails vary per order. The rail in this manual may not exactly match the rail for your system. Please refer to the specifications or quick installation guide that came with your purchased product.

Prepare the Rails:

1. Pull on the “Front-Release” to unlock the inner channel from the Slide Assembly.

2. Release the Detent-Lock and push the Middle Channel inwards to retract the Middle Channel.

3. (Optional) For Aluminium Racks, remove the Metal Spacer.

Install Rails onto Rack:

4. Align the Front Bracket with the Mounting Hole on the rack post.

5. Push in to assemble the Front Bracket onto the Rack. The bracket is now fixed.

6. Refer to steps 4 and 5 to assemble the End Bracket onto the rear of the Rack.

7. (Optional) Use M6x10L screws to secure the rails with posts if needed.

Install Chassis into Rack:

8. Assemble the inner channel (removed in step 1) onto the chassis using the screws provided.

9. Push the chassis with inner channels into the Slide assembly on the rack to complete Rack Installation.


What are the connector and jumper details for the 2-Bay HDD Backplane in the AIC RSC-1AT?

The 2-Bay HDD backplane features HDD connectors, SATA ports, and the following jumpers and connectors:

Power (JP1) Pinout:

• Pin 1: 12V

• Pin 2: GND

• Pin 3: GND

• Pin 4: 5V

LED I/O (J3, J7) Pinout:

• Fail LED (-)

• ACC LED (-)

• LED (+)

• GND

• Fail LED input

• ACC LED input


What are the connector and jumper details for the 4-Bay HDD Backplane in the AIC RSC-1AT?

The 4-Bay HDD backplane features connectors for HDD1, HDD2, HDD3, and HDD4, an SFF-8643 Connector, and the following connectors and jumpers:

JACT_LED: External HDD Activity LED Input (Active low) Pinout:

• Pin 1: GND

• Pin 2: HDD1

• Pin 3: HDD2

• Pin 4: HDD3

• Pin 5: HDD4

JFAIL_LED: External HDD Fail LED Input (Active low) Pinout:

• Pin 1: GND

• Pin 2: HDD1

• Pin 3: HDD2

• Pin 4: HDD3

• Pin 5: HDD4

CN6 & CN7: Power Connector Pinout:

• Pin 1: +12V

• Pin 2: GND

• Pin 3: GND

• Pin 4: +5V

JCPLD_SEL: SGPIO (8-pin block)


What are the function and setting options for the JCPLD_SEL jumper on the 4-Bay HDD Backplane of the AIC RSC-1AT?

Pin Status Description
1, 2 Open Disable External Access LED input (JP11).
Close Enable External Access LED input (JP11).
3, 4 Open Access LED from HDD Pin P11.
Close Access LED from SGPIO.
5, 6 Open Identify behavior according to host.
Close Identify LED blinking behavior.
7, 8 Open Disable SGPIO.
Close Enable SGPIO.

CLICK HERE TO DOWNLOAD AIC RSC-1AT (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.