PDF Content Summary: Agilent U1241A/U1242A Handheld Digital Multimeter Quick Start Guide U1241A U1242A Annunciator Keypad Rotary Switch Input Terminal Measurement Functions Input terminal Overload Protection

Voltage 1000 V R.M.S.

Diode 1000 V R.M.S COM Resistance < 0.3 A short circuit current Capacitance μA & mA μA mA COM 440 mA/1000 V 30 kA/fast-acting fuse A A COM 11A/1000 V 30 kA/fast-acting fuse Temperature +T1 –T1 1000 V R.M.S. Temperature (for U1242A) +T2 –T2 440 mA/1000 V 30 kA/fast-acting fuse WARNING To avoid damaging this device, do not exceed the input limit. Agilent Technologies

Annunciator Display 13 15 17 9 11

7 5 3 1 6 4 2 8 10 12 14 16 18 19 20 21 22 23

No. Descriptions No. Descriptions 1 21-segment analog bar graph display 12 MINMAX Recording mode 2 Capacitor discharge indicator 13 Harmonic Ratio mode (for U1242A) 3 Cold junction of ambient temperature 14 Data logging mode (for U1242A) 4 Audible continuity for resistance and diode function 15 Data logging viewing mode (for U1242A) 5 Primary display 16 Auto or manual data logging mode and datalog viewing mode 6 AC or DC measurement mode 17 Secondary display (temperature display) 7 Auto range 18 Null math function 8 Diode / Audible continuity 19 Thermocouple type for temperature measurement

9 T1, T2 and T1 – T2 temperature measurements scan (for U1242A) 20 Primary measurement units 21 Measurement range

10 Data hold 22 Low battery indicator 11 T1, T2* and T1 – T2* temperature measurements 23 Auto power off indicator *T2 temperature measurement and delta (T1 – T2) are only available for U1242A. U1241A/U1242A Quick Start Guide Features and Functions Rotary Switch Keypad Function First level functions Range Second level functions (press . ......... ) Range OFF Turn off the meter DCV measurement 0.1 mV to 1000 V ACV measurement 0.1 mV to 1000 V Harmonic ratio (for U1242A) 0.0% to 99.9% Diode measurement Switch counter measurement Resistance measurement 0.1 W to 100 MW Audible continuity measurement Capacitance measurement 0.1 nF to 10 mF DCµA 0.1 μA to 10 mA ACµA measurement 0.1 μA to 10 mA DCmA 0.01 mA to 440 mA ACmA measurement 0.01 mA to 440 mA mA% scale DCA 0.001 A to 10 A ACA measurement 0.001 A to 10 A

T1 T1 temperature –40 °C to 1000 °C T2 and T1–T2 temperature measurements (for U1242A) Actions Steps Turns ON backlight Press Checks battery capacity Press and hold for > 1 second Freezes the measured value Press Starts MIN/MAX/AVG recording Press and hold for > 1 second Offsets the measured value Press Scan the measured temperature (for U1242A only) Press and hold for > 1 second Changes the measuring range Press Turns on auto range Press and hold for > 1 second Measures frequency for AC signal Press Starts manual data logging Press and hold for > 1 second –40 °C to 1000 °C

U1241A/U1242A Quick Start Guide Tilt Stand Tilt stand at 60° Tilt stand at 30°

Safety Information The Agilent U1241A and U1242A are safety-certified in compliance with the following safety and EMC requirements: • IEC 61010-1:2001 / EN61010-1:2001 • USA: UL 61010-1:2004 • Canada: CSA C22.2 No. 61010-1:2004 • IEC 61326-1:2005/ EN 61326-1:2006 • Canada: ICES-001:2004 • Australia/New Zealand: AS/NZS CISPR11:2004 Safety Notices CAUTION A CAUTION notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met. WARNING WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not correctly performed or adhered to, could result in per sonal injury or death. Do not proceed beyond a WARN ING notice until the indicated conditions are fully understood and met. Safety Symbols Caution, risk of danger (refer to this manual for specific Warning or Caution information) Caution, risk of electric shock Earth (ground) terminal

CAT III 1000 V CAT IV 600 V Category III 1000 V Overvoltage Protection Category IV 600 V Overvoltage Protection

For further safety information details, refer to the Agilent U1241A and U1242A Handheld Digital Multimeter User’s and Service Guide. ♥Agilent Technologies, Inc. 2007-2009 Second Edition, April 01, 2009 Printed in Malaysia Agilent Technologies U1241-90024