What are the benefits of using a SEC AMERICA 1733 Pump Sentry™ Battery Backup System?
The SEC AMERICA 1733 Pump Sentry™ product line is designed to give you the peace of mind you want during a rain storm that leads to a power outage. When the power goes out, Pump Sentry™ automatically switches to battery power and keeps your main sump pump running and your basement dry. When power returns, Pump Sentry™ automatically starts recharging the battery, preparing for the next power outage.
What are the features of the SEC AMERICA 1733 Pump Sentry™ Battery Backup System?
The features of the SEC AMERICA 1733 Pump Sentry™ Battery Backup System include:
Plug & Play – Can be installed with any sump pump in under 10 minutes.
No need to install an additional pump or replace the existing one
Clean Pure Sine Wave Output.
Keeps sump pump operating at peak level when power is lost
Durable – not a throw-away appliance – 10 year life expectancy.
Specifically designed for pump operation
Made in the U.S.A. – Locally serviceable
3 Year Warranty
How do I mount the SEC AMERICA 1733 Pump Sentry™ Battery Backup System?
Pump Sentry™ conveniently mounts to the wall or a shelf. It should be mounted at close proximity to a grounded AC outlet, provided the AC cord from the Pump Sentry will reach it.
How do I make the connections for the SEC AMERICA 1733 Pump Sentry™ Battery Backup System?
1) Make sure the On/Off switch is in the OFF position.
2) Connect battery to Pump Sentry™ using supplied cables
3) Plug your Pump into Pump Sentry’s AC outlet.
4) Plug the Pump Sentry into a 120 volt AC outlet.
5) Turn the On/Off switch to ON.
What is the required battery setup for the SEC AMERICA 1733 Pump Sentry™ Battery Backup System?
Only batteries conforming to Battery Council International (BCI) group size 29 or larger are recommended. Only lead acid or AGM batteries are designed for the type of service which Pump Sentry™ requires. INSTALL ONLY deep cycle batteries. The marine-variety is acceptable. DO NOT use car batteries.
Can I connect multiple batteries to the SEC AMERICA 1733 Pump Sentry™ Battery Backup System?
Up to three batteries maybe connected to increase back up time. The connection is made with parallel multiple battery connections.
What are the electrical specifications for the SEC AMERICA 1733 Pump Sentry™ Battery Backup System?
| Model 1733 | |
|---|---|
| Input Volts | 120 VAC; 60Hz |
| Output Wave Shape (backup) and Output Wave Shape (on line) | Low Distortion Sine Wave with Distortion <3% into resistive loads |
| Start Up Surge Capacity | 45 A |
| Maximum Continuous Output Power | 1800 Watts |
| Audible Alarm – Imminent Shutdown | When battery has declined < 10.8V |
| VISUAL LED’S – Active when lit – LED (A) | Power present at output receptacle. |
| VISUAL LED’S – Charging LED Indicator (B) – Blinking | Blinking When Charging |
| VISUAL LED’S – Charging LED Indicator (B) – Fully ON | Battery is full-charging suspended |
| VISUAL LED’S – Replace Battery LED Indicator (C) – Fully ON | Battery is degraded from long term use |
| Weight | 22 / 10 (lb. / Kg.) |
| Size | 22 x 8.6 x 3.5 / 56 x 22 x 9 (in. / cm.) |
| Mounting Hole Centers | 17 x 8.2 / 43.5 x 21 (in. / cm.) |
| Supplied Cables | BC-42 / 4 ft. #2 gauge |
How can I find the single battery operation hours for the SEC AMERICA 1733 Pump Sentry™ Battery Backup System?
The single battery operation hours are provided in the table below (Pump Current Rating – 5A and 8A):
| Battery Size Group Size | Battery BCI Typical Ah | No. of Batteries | Pump Current Rating – 5A Low Duty Cycle Hours | Pump Current Rating – 5A High Duty Cycle Hours | Pump Current Rating – 8A Low Duty Cycle Hours | Pump Current Rating – 8A High Duty Cycle Hours |
|---|---|---|---|---|---|---|
| 24 | 80 | 1 | 25.3 | 8.4 | 16.9 | 3.6 |
| 27 | 90 | 1 | 28.5 | 9.5 | 19.0 | 6.3 |
| 29 | 95 | 1 | 30.1 | 10.0 | 20.1 | 6.7 |
| 30 | 110 | 1 | 34.8 | 11.6 | 23.2 | 7.7 |
| 31 | 125 | 1 | 39.6 | 13.2 | 26.4 | 8.8 |
| 40 | 200 | 1 | 63.3 | 21.1 | 42.2 | 14.1 |
| 8D | 245 | 1 | 77.6 | 25.9 | 51.7 | 17.2 |
How can I find the multiple battery operation hours for the SEC AMERICA 1733 Pump Sentry™ Battery Backup System?
The multiple battery operation hours for increased time are provided in the table below (Pump Current Rating – 5A and 8A):
| Battery Size Group Size | Battery BCI Typical Ah | No. of Batteries | Pump Current Rating – 5A Low Duty Cycle Hours | Pump Current Rating – 5A High Duty Cycle Hours | Pump Current Rating – 8A Low Duty Cycle Hours | Pump Current Rating – 8A High Duty Cycle Hours |
|---|---|---|---|---|---|---|
| 24 | 80 | 2 | 50.7 | 16.9 | 33.8 | 11.3 |
| 27 | 90 | 2 | 57.0 | 19.0 | 38.0 | 12.7 |
| 29 | 95 | 2 | 60.2 | 20.1 | 40.1 | 13.4 |
| 30 | 110 | 2 | 69.7 | 23.2 | 46.4 | 15.5 |
| 31 | 125 | 2 | 79.2 | 26.4 | 52.8 | 17.6 |
| 24 | 80 | 3 | 76.0 | 25.3 | 50.7 | 16.9 |
| 27 | 90 | 3 | 85.5 | 28.5 | 57.0 | 19.0 |
| 29 | 95 | 3 | 90.3 | 30.1 | 60.2 | 20.1 |
| 30 | 110 | 3 | 104.5 | 34.8 | 69.7 | 23.2 |
| 31 | 125 | 3 | 118.8 | 39.6 | 79.2 | 26.4 |