PDF Content Summary: SHURFLO®358 BILGE PUMP INSTALLATION & OPERATION INSTRUCTIONS ADVANCED BILGE FEATURES ❚ Anti-Airlock ❚ Tough Nylon Housing ❚ Tinned 6’ Wire Assembly ❚ Water Cooled Motor ❚ Submersible ❚ Ignition Protected ❚ ISO 8846, ABYC, NMMA Type Accepted, CE Remove ALL 7 screws for cleaning if necessary. Baseplate tabs press in for easy removal. ELECTRICAL NOTE: Typical circuit only, consult boat wiring diagram. MOUNTING ❚ Locate the pump in the deepest posi tion in the bilge. Keep away from high heat source. ❚ Mount quick disconnect bracket to bulkhead or stringer with #10 S.S. screws. Do not drive screws through hull. ❚ Route smooth I.D. discharge tubing to a thru-hull fi tting well above the water line. Avoid any sagging or loops in the tubing. Tubing must go up from the pump to the thru-hull fi tting. ELECTRICAL Use 16GA wire for all circuits. If instal lation is over 20 feet, use 14GA wire. Brown pump wire must be hooked to positive power for maximum fl ow. Wire is tinned to prevent corrosion. PANEL SWITCH: Attach all wires to UL Marine approved duty switch with auto-off-manual, rated at or above 15 amps. FUSE: Install a fuse per pump label specifi ca tions . CONNECTIONS: Wire connections should be made above the highest possible water level. Seal wire connections to prevent corrosion and electrolysis. OPERATION DO NOT RUN PUMP DRY. ALWAYS TEST PUMP AND SWITCH BEFORE LEAVING DOCK.

FLOW MANAGEMENT SOLUTIONS 911-742 REV. J 1 OPERATION MANUAL MODE: To turn pump on, turn manual power switch on. If pump does not turn on, turn switch off, check power, fuses, connections, wires. Retry. If pump does not turn on, check pump motor. FLOW GPH [LPH] TECHNICAL DATA Name Voltage Model # 0' [0m] 1' [3m] 6' [2m] Max. Head ft. [m] Max. Amps Fuse Outlet Port Dims. 1500 12 V* 358-000-00 1800 [6813] 1700 [6434] 1600 [6056] 14 [4.27] 8 10 1-1/8" 7-1/4" x 6" 2000 24 V* 358-010-00 2200 [8327] 2000 [7570] 1900 [7191] 18 [5.5] 10 15 1-1/8" 7-1/4" x 6" 1500 12 V 358-100-00 1800 [6813] 1700 [6434] 1600 [6056] 14 [4.27] 4 6 1-1/8" 7-1/4" x 6" 2000 24 V 358-110-00 2200 [8327] 2000 [7570] 1900 [7191] 18 [5.5] 5 6 1-1/8" 7-1/4" x 6" *Specifications given at design voltage 13.6 VDC per ABYC recommendations. Pump Power leads: 6 ft. [1.8 M] #16 tinned stranded copper wire to minimize corrosion. Positive (+) brown; Ground (–) black. Temperature limits: 33ºF—140ºF [0ºC—60ºC]. All models rated for continuous duty. Approvals: Ignition Protected, ISO 8846, ABYC, NMMA Type Accepted, CE.

TROUBLESHOOTING NO WATER PUMPED / PUMP NOT RUNNING √ Blown fuse. Wire connections. Im peller or float switch plugged with debris. REDUCTION IN WATER FLOW √ Impeller/screen plugged with de bris. Pinch/clogged discharge tub ing. Discharge tubing sagging below pump causing air lock. Tubing must go up from pump to thru-hull fit ting. Low voltage to pump; check battery/wire connections. LOW FLOW √ Polarity reversed; check wiring. Use only smooth bore (I.D.) discharge tubing. Is thru-hull fitting I.D. smaller than pump discharge port? FLOW MANAGEMENT SOLUTIONS  WARNING Do not pump oil, diesel fuel, gasoline or other flammable liquids with this pump. This pump does not prevent the discharge of oil or other chemicals into the water. Please take appropriate measures to prevent discharging oil or other chemicals and safeguard the environment. Always disconnect power before servicing pump. Always use fuse size specified in specifications. These bilge pumps are designed to evacuate standing bilge water only. These pumps may not prevent boat sinkage due to storms, rough weather, unsafe boating, improper installation procedures or hull damage.

3545 HARBOR GATEWAY SOUTH, SUITE 103, COSTA MESA, CA 92626, (800) 854-3218 SHURFLO.COM All Pentair trademarks and logos are owned by Pentair, Inc. All other brand or product names are trademarks or registered marks of their respective owners. Because we are continuously improving our products and services, Pentair reserves the right to change specifications without prior notice. Pentair is an equal opportunity employer. 2 911-742 Rev. J 09/14 ©Pentair, Inc. All Rights Reserved.


FREE ENGLISH PDF

OPERATING INSTRUCTIONS

USER GUIDE - USER MANUAL

OWNER GUIDE - OWNER MANUAL

REFERENCE GUIDE - REFERENCE MANUAL

INSTRUCTION GUIDE - INSTRUCTION MANUAL

Leave a Reply