What is the recommended power-on sequence for the product and Image Sensor Controller?
Turn ON the power of this product and the Image Sensor Controller at the same time or turn on this product first.
How should the product be maintained?
Turn OFF the power and ensure safety before maintenance.
Lightly wipe off dirt with a soft cloth.
Never use paint thinner, benzene, acetone, or kerosene to clean the product.
What is the warming up procedure for the product?
After turning on the power supply, allow the controller to stand for at least 30 minutes before use. As the circuits are unstable immediately after power ON, brightness may gradually change.
How do I mount the camera connection cable to the camera?
Align the inner grooves of the connectors on the camera connection cable side and camera side with each other, and insert the cable until it clicks to lock it.
How do I remove the camera connection cable?
Hold the connector on the camera connection cable side in the arrowed direction, and pull it out straight.
Do not grab the cable and pull it out with an unreasonable force to remove it. Doing so might cause breakage.
What important precautions should be taken when handling the camera connection cable?
Do not touch the internal terminals of the connector. Doing so might cause a failure.
Avoid the cable and connector from being vibrated or shocked.
Do not install the devices loading the connector constantly, for example, if the cable is being tensed.
What are the installation environment precautions for safe use?
Do not use the product in areas where flammable or explosive gases are present.
To secure the safety of operation and maintenance, keep an enough distance from high-voltage devices and power devices.
Tighten the screws with the specified torque in this document.
Clean the ventilation holes regularly to prevent dust and particles from clogging them. If they are blocked, heat is trapped inside, causing a malfunction.
What are the power supply and wiring precautions for safe use?
Connect only to the applicable image sensor controller (FH series) and camera (FH-S series, FZ-S series). Use of other devices may result in fire, explosion, malfunction or failure.
Make sure to use the product with the power supply voltage specified.
Do not reverse the polarity of the power connection.
Do not apply voltages or AC power supplies that exceed the rated voltage.
Supply power from a DC power supply for which measures have been applied to prevent high voltages (e.g., a safety extra low voltage circuit).
Be sure to remove the terminal block from the main unit when wiring the product to the 24 V external input terminal block.
To wire the terminal block, connect an applicable cord (AWG14-12) and the length of the power supply cable should be as short as possible (30 m max).
Always turn OFF the power of the product before connecting or disconnecting a cable.
Secure the minimum bending radius of the cable for at least 20 mm. Otherwise the cable may be damaged.
Do not apply excessive stress to the cables and connectors. It may damage the cables and connectors.
Before turning on the power after the wiring is completed, verify that the power is correct, that there are no incorrect connections such as a shorted load circuit, and that the load current is suitable. Incorrect wiring may cause damage and failures.
What other precautions should be taken for safe use?
The main body may become extremely hot while the power is supplied or immediately after the power is turned OFF. Do not directly touch the main body.
If you notice an abnormal condition such as a strange odor, extreme heating of the unit, or smoke, immediately stop using the product, turn off the power, and consult your dealer.
Do not attempt to disassemble, deform by pressure, incinerate, repair, or modify this product.
Do not drop or impose excessive vibration or shock on the product. It may cause breakdown of the product.
When disposing of the product, treat it as an industrial waste.
What are the functions of the product’s parts?
| No. | Name | Description |
|---|---|---|
| 1 | Camera connecting cable | Connects to the extension connector of the camera. |
| 2 | 24 V external power supply input terminal block | Connects the 24 VDC power supply. Model: BLF5.08HC/02/180SNB (Manufactured by Weidmuller) |
| 3 | 24VDC(+) | 24 V power supply input |
| 4 | 24VDC(-) | 0 V power supply input |
| 5 | POWER LED | Lights up green when the 24 V power is supplied. |
| 6 | RUN LED | Lights up green when preparation of lighting is complete. |
| 7 | ERROR LED | Lights up red when an error occurs. |
What are the important considerations for terminal block wiring?
To wire the terminal block, connect an applicable cord (AWG14-12) and the length of the power supply cable should be as short as possible (30 m max).
Be sure to wire the power supply separately from other devices. Wiring the power supply together with other devices or wiring it to the same duct may result in erroneous operation or damage of the product due to interference by electromagnetic induction.
Avoid the wire and terminal block from being vibrated or shocked.
Avoid the wire from being tensed. Do not install the devices loading the terminal block constantly, for example, if the wire is being tensed.
What is the correct power ON sequence for the Lighting Controller (FL-MD MC)?
When supplying power to the Lighting Controller (FL-MD MC), make sure to turn ON the power supply to the product first or at the same time as the Image Sensor Controller. If the Image Sensor Controller is powered ON first, the input power to the product may not be recognized, causing the ERROR LED to light up and the lighting not to turn ON. In this case, turn ON the power of the Image Sensor Controller again.
If power supply input to FL-MD MC is first:
FL-MDMC: ON
Power supply input: OFF
Image Sensor: ON
Controller power input: OFF
This sequence normally turns ON and the lighting turns ON.
If power input to the FL-MDMC and the Image Sensor Controller are provided at the same time:
FL-MDMC: ON
Power supply input: OFF
Image Sensor: ON
Controller power input: OFF
This sequence normally turns ON and the lighting turns ON.
If power supply input to the Image Sensor Controller is first:
FL-MDMC: ON
Power supply input: OFF
Image Sensor: ON
Controller power input: OFF
This sequence causes the ERROR LED to turn ON and therefore the lighting does not turn ON as the power input to FL-MDMC is not recognized. Turn ON the power of the Image Sensor Controller again.