What are the important safety warnings for the LPOW HTD8813C thermometer?
Warnings are identified by the WARNING symbol. Please adhere to the following:
• The LPOW HTD8813C is to be operated by consumers in the home setting and primary care setting as a screening tool. This manual, accessories, direction for use, all precautionary information, and specifications should be read before use.
• This product is designed to measure human body temperature on the forehead. Do not use it for any other purpose.
• Do not use the thermometer if it malfunctions or has been damaged in any matter.
• When the ambient temperature of the thermometer changes too much, such as moving it from a place of lower temperature to a place of higher temperature, allow the thermometer to remain in a room for 30 minutes where the temperature is between 15°C to 35°C (59°F – 95°F).
• Remove primary batteries if the equipment is not likely to be used for a long time.
• This product is not waterproof; do not immerse it in water or other liquid. For cleaning and disinfection, please follow the “Care and Storage” section requirements.
• Do not touch the sensor of infrared detection with your fingers.
• If a cold compress is on the forehead of a patient with a fever, or if other measures are taken to cool down, the temperature data will be low. Avoid measuring body temperature in this case.
• When measuring human forehead temperature, please select “body” mode. For measuring other objects, liquids, food, and other temperatures, please select “surface” mode.
• This product must be operated in a stable environment. If the ambient environment changes, please note whether there is fog on the sensor. If any, remove the fog before use by following the “Care and Storage” section.
• Do not place the device near strong electrostatic fields or strong magnetic fields to avoid impacting the accuracy of the measurement data.
• Do not mix old and new batteries to avoid damage to the product.
• The accuracy of measurements may be affected when the forehead is covered by hair, perspiration, a cap, or a scarf.
• Keep the device out of the reach of children/pets. When not in use, store the device in a dry room and protect it against extreme moisture, heat, lint, dust, and direct sunlight. Never place any heavy objects on the storage case.
• Do not throw batteries into a fire.
• Only use recommended batteries. Do not use rechargeable batteries.
• Do not fall, disassemble, or modify the device.
• This device comprises sensitive components and must be treated with caution. Observe the storage and operating conditions described in the “Technical Specifications’ section.
• Do not perform servicing/maintenance while the thermometer is in use.
• When using, do not touch the battery and the patient simultaneously.
• Do not use the device if it is damaged, degraded, or loosened in any way. The continuous use of a damaged unit may cause injury, improper results, or serious danger.
What is the intended use of the LPOW HTD8813C thermometer?
What do the controls and symbols on the LPOW HTD8813C mean?
Controls and Indicators:
1. LCD Display
2. Battery Cover
3. ON/Scan Button
4. Set Button
5. MEMO Button
6. MODE Button
7. IR Sensor
LCD Display Symbols:
1. Surface Mode
2. Body Mode
3. Digital Display
4. Smile or Cry Indicator
5. Battery Indicator
6. Buzzer on/off Indicator
7. Memory number
8. °F (Fahrenheit)
9. °C (Celsius)
10. Memory
Equipment Symbols Table:
| Symbol | Description |
| Warning | Compliance with WEEE Standard |
| Non sterile Packaging | DO NOT THROW AWAY Intended for multiple use |
| Refer to Operating instructions | Operating atmospheric pressure |
| Operating Temperature | SN: serial number |
| Operating Humidity | recyclable |
| manufacturer | FC: This device compiles with Part 15 of FCC (Federal Communications Commission) Rules. |
| IP22 | The first number 2: Protected against solid foreign objects of 12.5 mm Ø and greater. The second number: Protected against vertically falling water drops when enclosure titled up to 15°. |
How do I install or replace the batteries in the LPOW HTD8813C?
The LPOW HTD8813C thermometer does not operate with dead batteries. Please install new batteries before first use.
1. Pull the battery cover downward, toward the bottom of the thermometer, and remove the battery access door.
2. Insert two AAA size batteries according to the “+” and “-” polarity markings inside the compartment.
3. Close the battery cover by sliding it back in until it snaps in place.
For Replacing Batteries:
• Open and release the battery cover following the indicator on its surface. Ensure the thermometer is powered off before changing batteries.
• Remove the old batteries and replace them with 2 new AAA batteries. Make sure to align them properly as indicated inside the battery cover.
• Do not dispose of used batteries in household waste. Take them to special local collection sites.
• If the system is latched up after changing the battery, take the batteries out, wait 30 seconds, and then load the batteries again.
• The typical service life of new and unused batteries is 2000 measurements for an operation time of 18s.
• Only use the recommended batteries. Do not use non-rechargeable batteries, and do not burn them.
• Remove the batteries if the thermometer is not to be used for a long period.
How do I take a temperature measurement with the LPOW HTD8813C thermometer?
Before Applying the Thermometer
Be sure to read and understand all warnings in the instructions before use.
• The ambient temperature around the person being tested should be stable. They should be kept away from large flow fans, air-conditioning vents, etc.
• When moving from a place of lower temperature to a place of higher temperature, the person should remain in the test environment for more than 5 minutes to allow their body temperature to be consistent with the ambient temperature before re-measurement.
• Wait at least 1 second for the next measurement. If you perform five continuous measurements, it is recommended to wait at least 30 seconds before continuing.
• Do not use the thermometer in a place where the sun is strong.
• If for some reason a low forehead temperature measurement is recorded, you can try to align the thermometer behind the ears.
General Setup and Use
1. Turn on the thermometer by pressing the On/Scan button. The thermometer will perform a self-test with all segments displayed for 2 seconds.
2. Align the thermometer with the middle of the forehead, between the eyebrows. Keep a vertical distance of 1cm-5cm (0.4-2in). Press the On/Scan button to start the measurement.
3. After the full display sequence, you will hear a “beep beep beep,” which means the measurement is complete. The measured temperature value will be displayed on the LCD. The backlight will also display according to the reading.
• Green Backlight: Ready for the next measurement. For temperatures between 35.5°C – 37.3°C (95.9°F – 99.1°F), this indicates a normal temperature.
• Yellow Backlight: For temperatures between 37.4°C – 38.0°C (99.3°F – 100.4°F), this indicates a slight fever warning. Please pay attention to body temperature.
• Red Backlight: For temperatures above 38.1°C (100.6°F), this indicates a high fever. Please take action to cool down or consult a doctor.
To ensure accuracy, wait at least 30 seconds after 5 consecutive measurements before taking another.
How do I switch between Body mode and Surface mode on the LPOW HTD8813C?
• “body” mode is used for measuring human body temperature (this is the factory default).
• “surface” mode is used to measure the surface temperature of objects, liquids, food, etc.
How do I recall and erase memory data on the LPOW HTD8813C?
1. In either the boot or shutdown state, short press the MEMO button to view the history of measured values.
2. An empty memory cell will show “—°C” or “—°F”.
3. Up to 50 temperature readings can be stored. When the memory is full, new readings will automatically overwrite the oldest historical data.
4. To erase all stored data, press and hold the MEMO button in boot mode until the LCD displays “CLr”. This indicates that all stored data has been cleared completely.
How do I change the parameter settings on the LPOW HTD8813C?
1) Unit Set-F1 (Temperature Unit)
In boot mode, long press the SET button to enter F1. Press the “MODE” or “MEMO” button to switch between Celsius (°C) and Fahrenheit (°F). Press the SET button to confirm the unit setting. (Factory default is Fahrenheit).
2) Fever alert set-F2
While in the F1 state, press the SET button to enter F2. Press the “MODE” button to decrease the fever alert temperature by 0.1°C, or press the “MEMO” button to increase it by 0.1°C. Long press either button to accelerate the speed of temperature adjustment. Finally, press the SET button to save. (The factory default is 38.1°C).
3) Prompt sound settings-F3
While in the F2 state, short press the SET button to enter F3. Press the MODE or MEMO button to switch the prompt sound on or off. Press the SET button to confirm the setting. (The factory default is the voice prompt to open).
4) Overall temperature offset value-F4
This setting is used to adjust for environmental variations or different population characteristics. While in the F3 state, short press the SET button to enter F4. Press the MEMO button to increase the offset by 0.1°C or the MODE button to decrease it by 0.1°C. Long press for faster adjustment. Then press the SET button to confirm the parameter setting. The adjustment range is -5°C to +5°C. (The factory default is 0).
5) Exit setting mode
In the F4 mode, pressing the SET button will automatically turn off the screen and exit the setting mode.
How do I clean and care for my LPOW HTD8813C thermometer?
• The lens is very delicate; it is very important to protect the lens from dirt and damage.
• Use a clean, soft cloth to clean the surface of the device and LCD. Do not use solvents or immerse the device in water or other liquids.
• Always keep the thermometer within the specified storage temperature range (-20°C to 55°C or -4°F to 131°F) and humidity range (≤93% non-condensing).
• It is recommended to store the thermometer in a dry location free from dust.
• Do not expose the thermometer to direct sunlight, high temperature/humidity, or any extreme environment, as this may reduce its function.
• When the ambient temperature of the thermometer changes significantly (e.g., moving it between a colder and warmer location), allow it to remain in a room for 30 minutes where the temperature is between 15°C to 35°C before use.
How should I dispose of the LPOW HTD8813C and its batteries?
• Used batteries should not be disposed of in the household rubbish. Used batteries should be deposited at a collection point.
• At the end of its life, the appliance should not be disposed of in household rubbish. Enquire about the options for environment-friendly and appropriate disposal. Take local regulations into account.
How do I troubleshoot common issues with the LPOW HTD8813C thermometer?
| Message | Situation | Solution |
|---|---|---|
| Hi | Temperature taken is not within the typical human temperature range (34.0°C-42.9°C or 93.2°F-109.2°F). | Make sure the thermometer is used for forehead measurement, not another human body site. |
| Lo | Measured over the distance of 1-5 cm (0.4-2 in). Incorrect test position. | Optimum measurement distance is 1cm. Refer to the manual for measuring position and distance. |
| Lo | Subject’s forehead hair, Antipyretic stickers, head with sweat, etc. Some people’s body temperature is lower than the general population. | Ensure the subject sits quietly for 5-10 minutes before the test. The main concern is fever temperature. |
| Lo | F4 overall temperature offset is set incorrectly. | Adjust the temperature offset value. |
| Err | Operating temperature exceeds the range of specified temperature. | Move to a room within the operating range and wait 30 minutes before taking a temperature. |
| Flashing screen | The screen flickers, then automatically turns off. Battery capacity is too low. Taking temperature is not allowed. | Replace the battery. If the product has been damaged, it needs repairs. Install a new battery. |
| Flashing screen | Ambient temperature changes too fast. | Wait until the ambient temperature is stable. |
| POS (blank display) | (1) Power is off. (2) Improper battery installation. (3) The battery is exhausted. (4) Display remains blank. |
(1) Press the On/Scan button again. (2) Check the battery polarity. (3) Replace with a new battery. (4) Contact the retailer or service center. |
What are the technical specifications for the LPOW HTD8813C?
| Measurement Unit | °C / °F |
| Operating mode | Adjusted mode (Body mode) Direct mode (surface mode) |
| Measuring site | Forehead |
| Reference Body Site | Axillary |
| Rated output range | Body mode: 35.0°C – 42.0°C / 95.0°F – 107.6°F Surface mode: 0.0°C – 100.0°C / 32.0°F – 212.0°F |
| Extended output range | Body mode: 34.0°C – 34.9°C / 93.2°F – 94.8°F, 42.1°C – 42.9°C / 107.8°F – 109.2°F |
| Range | Body mode: 34.0°C – 42.9°C / 93.2°F – 109.2°F Surface mode: 0.0°C – 100.0°C / 32°F – 212°F |
| Accuracy | Body mode: 34.0°C-34.9°C: ±0.3°C / 93.2°F-94.8°F: ±0.5°F; 35.0°C-42.0°C: ±0.2°C / 95.0°F-107.6°F: ±0.4°F; 42.1°C-42.9°C: ±0.3°C / 107.8°F-109.2°F: ±0.5°F; Surface mode: ±2.0°C / ±3.6°F. |
| Display Resolution | 0.1°C / 0.1°F |
| Three-color Backlight (Color Alarm) | 35.5°C-37.3°C / 95.9°F-99.1°F: Green (Normal Temperature); 37.4°C-38.0°C (Alarm point) / 99.3°F-100.4°F: Yellow (Slight Fever); 38.1°C-42.9°C / 100.6°F-109.2°F: Red (High Fever) Note: 1. Surface mode is always with Green backlight. 2. In body mode 34.0°C-35.4°C is with green backlight. |
| Auto Power Off Time | ≤18s |
| Measuring Time | ≤2s |
| Measuring Distance | 1CM-5CM (0.4-2in) |
| Memories | 50 |
| Power Supply | 1.5V (AAA) alkaline battery X2 (IEC Type LR03) |
| Adaptable Range | 2.6V~3.6V |
| Operating Condition | Temperature: 15.0°C~35.0°C (59.0°F~95.0°F), Relative Humidity ≤85%, atmospheric pressure: 70Kpa-106Kpa |
| Transport and Storage Condition | Temperature: -20°C~+55°C / -4~131°F, Relative Humidity ≤93%, atmospheric pressure: 70-106Kpa |
| Weight (without batteries) | 90g |
| Size | L:138mm X W:95mm X H:40mm |
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
CLICK HERE TO DOWNLOAD LPOW HTD8813C (01) PDF DOCUMENT

New thermometer, new batteries, and temperature reading always displays low. 97.6 is the highest for both me and husband. It was down to 96 this morning. How to calibrate correctly.
On page 14 of the above manual you should see the “Troubleshooting” section. There is some situations & solutions for when the thermometer is reading “Lo”.