Free English LG AK-W090LCB0 (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.
CLICK HERE TO DOWNLOAD LG AK-W090LCB0 (01) PDF DOCUMENT
If this is not the document you want for this product, click here to see if we have any other documents for this product.
What are some tips for saving energy when using my LG AK-W090LCB0 air conditioner?
Here are some tips that will help you minimize the power consumption when you use the LG AK-W090LCB0 air conditioner:
• Do not cool excessively indoors. This may be harmful for your health and may consume more electricity.
• Block sunlight with blinds or curtains while you are operating the air conditioner.
• Keep doors or windows closed tightly while you are operating the air conditioner.
• Adjust the direction of the air flow vertically or horizontally to circulate indoor air.
• Speed up the fan to cool or warm indoor air quickly, in a short period of time.
• Open windows regularly for ventilation as the indoor air quality may deteriorate if the air conditioner is used for many hours.
• Clean the air filter once every 2 weeks. Dust and impurities collected in the air filter may block the air flow or weaken the cooling / dehumidifying functions.
What are the specifications for the LG AK-W090LCB0 air conditioner and similar models?
| Capacity | Model | Power Supply | Rated Current Max. (A) |
|---|---|---|---|
| 7.5 RT | AK-W090LCB0 | 380-415 V 3N~ 50/60 Hz | 43 |
| 10 RT | AK-W120LCB0 | 380-415 V 3N~ 50/60 Hz | 43 |
| 12.5 RT | AK-W150LCB0 | 380-415 V 3N~ 50/60 Hz | 60 |
| 15 RT | AK-W180LCB0 | 380-415 V 3N~ 50/60 Hz | 60 |
| 20 RT | AK-W240LCB0 | 380-415 V 3N~ 50/60 Hz | 88 |
| 25 RT | AK-W300LCB0 | 380-415 V 3N~ 50/60 Hz | 88 |
What safety precautions should be taken during the installation of the LG AK-W090LCB0?
To ensure safe installation of your LG AK-W090LCB0, please follow these guidelines:
• Do not use a defective or underrated circuit breaker. Use this appliance on a dedicated circuit.
• For electrical work, contact the dealer, seller, a qualified electrician, or an Authorized Service Center. Do not disassemble or repair the product yourself.
• Always ground the product to prevent risk of fire or electric shock.
• Install the panel and the cover of the control box securely.
• Always install a dedicated circuit and circuit breaker.
• Use the correctly rated circuit breaker or fuse.
• Use the specified wires to connect the unit.
• Do not install, remove, or re-install the unit by yourself (customer).
• Be cautious when unpacking and installing the product. Sharp edges could cause injury.
• Do not install the product on a defective installation stand.
• Be sure the installation area does not deteriorate with age. If the base collapses, the air conditioner could fall.
• If the power cord is damaged it must be replaced by the manufacturer or its authorized service agent.
• Always check for gas (refrigerant) pressure after installation or repair of product.
• Install the drain hose to ensure that water is drained away properly.
• Keep the product level even when installing it.
• Do not install the product where the noise or hot air from the outdoor unit could damage the neighborhoods.
• Do not install the product where it will be exposed to sea wind (salt spray) directly.
• Do not install the unit in potentially explosive atmospheres.
What are the key safety precautions for operating the LG AK-W090LCB0?
For safe operation of your LG AK-W090LCB0, please adhere to the following precautions:
• Ensure the power cable cannot be pulled out or damaged during operation.
• Do not place anything on the power cable.
• Do not touch or operate the product with wet hands.
• Do not place a heater or other appliances near the power cable.
• Do not allow water to run into electric parts.
• Do not store or use flammable gas or combustibles near the product.
• Do not use the product in a tightly closed space for a long time, as oxygen deficiency could occur.
• If flammable gas leaks, turn off the gas and open a window for ventilation before turning the product on.
• If you notice strange sounds, a smell, or smoke, turn the circuit breaker off immediately.
• Stop operation and close the window during a storm or hurricane.
• Do not open the panel of the product during operation.
• If the product becomes soaked (flooded or submerged), contact an Authorized Service Center.
• Ventilate the product from time to time when operating it together with a stove, etc.
• Turn the main power off when cleaning or maintaining the product.
• When the product is not used for a long time, turn off the circuit breaker.
• Do not expose your skin directly to cool air for long periods of time.
• Do not use the product for special purposes, such as preserving foods or works of art.
• Do not block the inlet or outlet of air flow.
• Use a soft cloth to clean. Do not use harsh detergents or solvents.
• Do not touch the metal parts of the product when removing the air filter, as they are sharp.
• Do not step on or put anything on the outdoor units.
• Always insert the filter securely and clean it regularly.
• Do not insert hands or other objects through the air inlet or outlet while the product is operating.
• Do not drink the water drained from the product.
• Use a firm stool or ladder when cleaning or maintaining the product.
What are the functions of the buttons on the wired remote controller for the LG AK-W090LCB0?
| Component | Function |
|---|---|
| Operation display window | Displays operation and settings status. |
| Back button | Moves to the previous stage from a menu’s setting stage. |
| Up/Down/Left/Right Button | Changes the menu’s setting value. |
| OK Button | Saves the menu’s setting value. |
| On/Off Button | Turns the air conditioner ON/OFF. |
What are the different operation modes available on the LG AK-W090LCB0?
You can select an operation mode by pressing the [<,>(left/right)] button on the main screen to highlight the mode category, then use the [^, V (up/down)] button to choose a mode. Some products may not support all modes.
| Mode | Description |
|---|---|
| Cool | Cools the room to the desired temperature. |
| Dry | It removes the moisture with cooling. |
| Heat | Heats the room to the desired room temperature. |
| Auto | The product automatically provides the appropriate fan speed based on the temperature of the room. |
| Fan | Fan only operation, no cooling or heating. |
How do I use the Cooling Operation on my LG AK-W090LCB0?
To use the cooling operation:
1. Set the desired temperature lower than the indoor temperature.
2. The minimum setting temperature is 18°C (or 20°C for UAE models). The temperature can be set in units of 1°C or 0.5°C depending on the indoor unit type.
3. If the setpoint is higher than the room temperature, the unit will not start cooling until the room temperature exceeds the setpoint.
4. Pressing the [On/Off] button while in cooling mode will shut off the operation.
Please note there is a 3-minute delay function to protect the compressor. After the unit stops, the compressor will wait 3 minutes before starting again.
The cool mode temperature setting range is:
• Common: 18°C~30°C (64°F~86°F)
• UAE Only: 20°C~30°C (68°F~86°F)
How does the Dry Operation work on the LG AK-W090LCB0?
The Dry Operation is used to dehumidify the room. The initial fan speed is set to “Low”, and this mode does not have a separate desired temperature setting. It effectively removes moisture, especially during the rainy season or when humidity is high. Pressing the [On/Off] button during this operation will shut it off.
How do I use the Fan Only Operation on my LG AK-W090LCB0?
The Fan Only Operation recirculates indoor air without cooling or heating. The initial fan strength is “High”, and there is no separate temperature setting for this mode. Pressing the [On/Off] button during this operation will stop the unit.
How do I operate the heating function on my LG AK-W090LCB0?
To use the heating operation:
1. Set the desired temperature higher than the current indoor temperature.
2. The minimum setting temperature is 16°C. You can select a desired temperature in the range of 16°C ~ 30°C.
3. If the desired temperature is set lower than the indoor temperature, warm air will not come out. On some products, the fan may recirculate room air or stop altogether.
4. Pressing the [On/Off] button while in heating mode will shut off the operation.
Note: The heating function is not available on cooling-exclusive models.
How do I control the desired temperature on my LG AK-W090LCB0?
In the main screen, press the [<,>(left/right)] button to select the desired temperature category, and then press the [^, V (up/down)] button to set the temperature. Temperature control is possible in Cooling, Heating, and Auto modes.
| Mode | Description |
|---|---|
| Cool | Set the desired temperature lower than the indoor temperature. You can select in the range of 18°C ~ 30°C (20°C ~ 30°C). If the set temperature is higher than the indoor temperature, cooling will not be performed. |
| Heat | Set the desired temperature higher than the indoor temperature. You can select in the range of 16°C ~ 30°C. If the set temperature is lower than the indoor temperature, heating will not be performed. |
| Auto | For cooling/heating products, you can select in the range of 18°C ~ 30°C. For cooling exclusive products, you can select Hot, A little hot, Adequate, A little Cold, and Cold. |
How can I check the current room temperature on the LG AK-W090LCB0 remote controller?
You can check the current indoor temperature on the main screen of the remote controller. Please note that due to the location of the temperature sensor, there may be a slight difference between the displayed temperature and the actual room temperature.
The remote controller will display ‘LO’ or ‘HI’ if the temperature is outside of its measurable range:
Single setpoint:
• Fahrenheit: Displays ‘LO’ below 52°F and ‘HI’ over 99°F.
• Celsius: Displays ‘LO’ below 10.5°C and ‘HI’ over 39.5°C.
Dual setpoints:
• Fahrenheit: Displays ‘LO’ below 34°F and ‘HI’ over 99°F.
• Celsius: Displays ‘LO’ below 0.5°C and ‘HI’ over 39.5°C.
How can I access and use the Lock Setting on the LG AK-W090LCB0 remote controller?
1. From the menu screen, press the [<,>(left/right)] button to select the “lock setting” category.
2. Press the [OK] button to move to the lock setting list screen.
3. In the lock setting list, use the [^, V (up/down)] button to select a lock function and turn it on or off.
The following lock functions are available:
| Lock | Description |
|---|---|
| All lock | It locks all button operation of the remote controller. |
| On/Off lock | It locks the On/Off button operation of the remote controller. |
| Mode lock | It locks the operation mode button operation of the remote controller. |
| Temperature range lock | It limits the range of the desired temperature that can be set. For a single setpoint, the lower limit can be set from 16-30°C (60-86°F), and the upper limit from 16/18-30°C (60/64-86°F). |
How do I check the filter sign and reset it on my LG AK-W090LCB0?
When it is time to clean the indoor unit filter, a cleaning message will appear. You can check the filter status and reset the reminder as follows:
1. Enter the menu screen and use the [<,>(left/right)] button to select the “Setting” category, then press [OK].
2. Select the “Function” category and press [OK].
3. In the function setting list, select “Filter Sign” and press [OK] to display the detail screen.
4. On this screen, you can see the filter usage time and remaining time. Press “Reset” to initialize the timer after cleaning the filter.
The filter usage status is displayed as follows:
| Filter sign | Description |
|---|---|
| Good | Usage time is 70% or less |
| Normal | Usage time is 71~80% |
| Caution | Usage time is 81~99% |
| Bad | Usage time is 100% |
What is the Smart Load Control (SLC) setting on the LG AK-W090LCB0, and how do I adjust it?
Smart Load Control (SLC) is a function that calculates the indoor air temperature, outdoor air temperature, and humidity to operate the unit more effectively. You can change the SLC stage value.
1. Enter the “Function” setting list.
2. Select the “Smart Load Control” category and press [OK] to move to the detail screen.
3. Use the up/down buttons to select a setting from Off or Step 0 to Step 4.
The SLC function can only be set when the installer setting’s outdoor unit function M/S setting is set to “Master”. It is only available on some products, and Step 4 may not be available on some indoor unit products.
How do I set the timers on my LG AK-W090LCB0?
You can set various timers through the remote controller’s menu.
1. In the menu screen, press the [<,>(left/right)] button to select the timer category, and press [OK].
2. In the timer setting list screen, press the [^, V (up/down)] button to select the timer you wish to set (Simple Timer, Turn-On Reservation, Turn-Off Reservation) and press [OK].
3. Follow the on-screen instructions to set the time/duration.
4. After setting the value, press [OK] to activate the timer.
Simple Timer:
• Sets the timer in the range of 1-7 hours in 1-hour increments.
• If the product is ON, the timer will turn it OFF after the set time. If the product is OFF, it will turn ON.
Turn-on Reservation:
• The product will automatically turn ON at the set time.
Turn-off Reservation:
• The product will automatically turn OFF at the set time.
For reservation timers, the setting is not cleared even if the unit is turned On/Off manually before the timer operates.
How do I add a new schedule on my LG AK-W090LCB0?
To add a new operating schedule, follow these stages:
1. Navigate to the “Schedules & Edit” screen and select “+ Add Schedule”.
2. Stage 1: Period setting – Set the start and end date for the schedule to be active.
3. Stage 2: Day of week setting – Set the day(s) of the week for the timer to perform. You can select ‘Everyday / Weekend / Weekdays / Individual selection’.
4. Stage 3: Time setting – Set the start time for the timer.
5. Stage 4: Operation setting – Set the timer operation information. This includes Operation (On/Off/Stop), Mode, Temperature, and Fan Speed. If ‘Stop’ is selected, you cannot set the other parameters.
When stages 1-4 are completed, a message ‘schedule is added’ will appear, and you will be moved to the View and edit schedule screen.
What is the Exception Day function on the LG AK-W090LCB0 and how do I use it?
The Exception Day function automatically stops the scheduled operation on a set timer day.
1. In the schedule list, select the “Exception Day” category and press [OK].
2. To add an exception day, select “+ Add exception day”, designate the year/month/day, and press [OK] to save.
3. To edit an existing exception day, select it from the list using the [^, V (up/down)] button and press [OK].
4. In the edit screen, you can delete or change the corresponding exception day’s settings. You must save any changes.
What maintenance can I perform myself on the LG AK-W090LCB0?
Before performing any maintenance, turn off the main power to the system. Before removing access panels, disconnect the power supply.
You can perform the following periodic maintenance:
• Cleaning Air Filters: This product has washable filters. Inspect them at least once a month (or every week for the first 4 weeks in new buildings). Wash the filters with a mild detergent and water. Ensure they are thoroughly dry before reinstalling them.
• Cleaning Condenser Coil: Unfiltered air can clog the condenser coil with dust and dirt. To clean the coil, vertically (along the fins) stroke the coil surface with a soft-bristled brush.
• General Inspection: Keep all vegetation away from the condenser coil area and conduct a general unit inspection on a regular basis.
What maintenance should be performed by a serviceman on the LG AK-W090LCB0?
To keep your unit operating safely and efficiently, a qualified serviceman should check the entire system at least once each year. The serviceman may examine these areas:
1. Filters (for cleaning)
2. Motors and drive system components
3. Condenser coils (for cleaning)
4. Safety controls (for mechanical cleaning)
5. Electrical components and wiring (for possible replacement or connection tightness)
6. Condensate drain (for cleaning)
7. Inspect the unit duct connections to ensure they are physically sound and sealed to the unit casing.
8. Inspect the unit mounting support to see that it is sound.
9. Inspect the unit to ensure there is no obvious deterioration.
How should I prepare my LG AK-W090LCB0 if it’s not going to be used for a long time?
1. Operate the air conditioner on air circulation mode (Fan Only mode) for 2 to 3 hours. This will dry out the internal parts.
2. Turn off the circuit breaker. Dirt may collect and may cause a fire if left on.
What should I do when I want to use my LG AK-W090LCB0 again after a long period of non-use?
1. Clean the air filter and re-install it in the indoor side. A “Filter access panel” label is attached on the filter access panel at the left side of the unit.
2. Check that the air inlet and outlet of the indoor/outdoor unit are not blocked.
What should I check if my LG AK-W090LCB0 does not operate?
If your unit does not operate, check the following:
• Have you made a mistake in timer operation? See reservation instructions.
• Has the fuse blown or has the circuit breaker been tripped?
• Does the remote controller display “CH” on the LCD? This means a protective device has been tripped. Please contact your dealer or service center.
What could be the cause of a peculiar odor from my LG AK-W090LCB0?
Check that this is not a damp smell exuded by the walls, carpet, furniture, or cloth items in the room.
Why does it seem like condensation is leaking from my LG AK-W090LCB0?
Condensation occurs when the airflow from the air conditioner cools the warm air in the room. This is a normal occurrence.
Why won’t my LG AK-W090LCB0 operate for about 3 minutes after being restarted?
This is a normal function of the air conditioner’s protection device, which prevents the compressor from being damaged. Wait about three minutes and the operation will begin.
What should I do if my LG AK-W090LCB0 does not cool or heat effectively?
If you experience ineffective cooling or heating, please check the following points:
• Is the air filter dirty? See air filter cleaning instructions.
• The room may have been very hot when the air conditioner was first turned on. Allow time for it to cool down.
• Has the setting temperature been set incorrectly? See temperature setting instructions.
• Are the unit’s air inlet or outlet vents obstructed?
What should I do if the remote controller display on my LG AK-W090LCB0 is faint or shows no display at all?
Check if the circuit breaker has been tripped. If it has, reset it. If the problem persists, contact a service center.
What happens if a power outage occurs while my LG AK-W090LCB0 is running?
The unit has an Outage Compensation Function. It automatically retrieves the previous operating conditions when power is restored. You do not need to press any buttons. (Note: Additional functions will not be retrieved automatically.)
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
CLICK HERE TO DOWNLOAD LG AK-W090LCB0 (01) PDF DOCUMENT