JABLOTRON ALARMS JA-162J (01) PDF MANUAL


Post questions, comments, reviews or page errors in the comment box below.

Your File is Ready … Download PDF

CLICK HERE TO DOWNLOAD JABLOTRON ALARMS JA-162J (01) PDF MANUAL


PDF Content Summary:

****** Page 1 ****** The JA-162J The JA-162J is a component of the JABLOTRON 100 system. It uses one way communication. It is designed to remotely control a security system, various appliances (using PG programmable outputs) or to trigger panic alarms. The remote control can also be enrolled to multipurpose relays such as the AC-16x series for direct relay control according to the pre-set mode. The remote is equipped with optical and acoustic indication. It checks its battery status and indicates when the battery is nearly discharged. One-way two-button keyfob B Figure: 1 — LED indication; A, B — buttons, see their functions according to table 1. Enrolling the remote control to a control panel There must be a JA-I lxR radio module installed in the control panel for the ability to work with a control panel. The remote can be enrolled to an arbitrary number of JABLOTRON 100 systems and one pair of buttons can control multiple sections in the system (common control). It occupies one position in the system. 1. The control panel has to be in service mode. 2. Basic procedure: a. b. c. Go to the F-Link software, select the required position in the Devices tab and launch enrollment mode. For the transmission of an enrollment signal press and hold buttons (A+B) simultaneously for at least 3 s (within this time the red LED flashes rapidly). After 3 s the enrollment signal is sent and confirmed by one long LED flash. Release both buttons and close enrollment mode. To set the keyfob to comply with security grade 2 use F-Link SW, Parameters tab and 0 o 0 the option "Perform EN50131-I". (See the JA-I OxK control panel installation manual) Notes: Enrolling the remote control to the system is possible by entering the production code via F-Link software. The production code is on the sticker with a bar code glued onto the battery holder inside the remote. All digits in the production code are required (1400-00-0000-0001 ) If you want to remove the remote control from the system (for instance when someone has lost it), erase it from the particular address of the control panel. Setting the properties Perform settings using F-Link software — Devices tab. Click on the JA-162J's Internal settings. Then a window appears automatically where you can set the following parameters: Functions of the buttons: set a particular function for the pair of buttons A+B (setting / unsetting typically, OFF / ON switching of some appliance, etc.) or a function for each single button A, B (gate opening, garage door opening, etc.) and a double press of the A+B buttons, i.e. the next button on the remote. For an option overview see table 1. Reaction for single buttons a R (A 1B) None (button not used) • • copy PG Change PG state • Silent panic ** • Audible panic ** ) Health troubles • • Report A, B, C, D Reaction for pressing simultaneously None (button not used) • • copy PG Change PG state • Silent panic **) • Audible panic ** ) Health troubles • • Report A, B, C, D For each function selected for a remote control button it is necessary to select the appropriate PG or sections to be controlled or from which reports should be sent (panic, etc.). For the common control of multiple sections it is not recommended to operate a common section, but to select the desired sections in the remote control internal settings. Notes: The „Copy PG" reaction to a double press can be used for a 1 s impulse only for the selected PG — double button pressing cannot send a Is activation signal repeatedly unlike single buttons. **) The reactions of the buttons which are not supported when the system is configured to comply with security grade 2. The option "Do not set with active zone", doesn't allow the system to be set using a remote control (keyfob) when any zone with an Instant reaction is active. To set the system all zones I detectors have to be in standby When the button on the remote control is pressed permanently (valid for the "Copy PG" function) activation is sent continuously every 1 s. The function can be used for the extension of the impulse of a PG output (the chosen PG output has to be set to the function "Copy"). The maximum length of keeping up the activation is 1 minute Take over a user's access privileges: Taking over a user's access privileges for the sections and time limited access according to the specific user, it respects individual access to the controlled section and also limited access to a section if pre-set. Factory settings: disabled. Take over a user's identity: The selected user will be visible as a source in the event log. Factory settings: disabled. Operation with a multipurpose relay (MPR) The remote control can also be enrolled to a multipurpose relay of the AC-16x series, to control a relay according to the chosen mode. Each button should be enrolled to the MPR with a different mode. One remote can be enrolled to multiple MPRs for example with a different function. When you enroll a keyfob to the control panel and also to an MPR within its RF range, don't select the same buttons. To enroll a keyfob to an MPR, follow the installation manual of the MPR. Locking the keyfob The remote control buttons can be locked (blocked) against accidental pressing. Locking is disabled by default, pressing any button triggers its function immediately. If the buttons are locked, a control panel command is sent when a button is pressed 2x quickly (2x per 1 s) it is also valid for the panic function. The lock can be activated by pressinq and holdinq the pair of buttons (A+B) at the same time. After pressing both buttons the red LED (1) flashes lx and subsequently after 3s the red LED starts flashing quickly, during LED flashing release button B and then press it again. Activation of the lock function is performed and confirmed by double flashes of the red LED and a double beep. After this confirmation release all buttons. The lock is deactivated by repeating the procedure above. Deactivation of locking is confirmed by one flash of the red LED and one beep. Caution: When a reaction for pressing buttons (A+B) simultaneously is set (for example a panic alarm or garage door control), it is necessary to mind that the action is performed first. Acoustic indication Acoustic indication can be completely disabled. The default is enabled. When any button is pressed it is followed by a short acoustic signal according to the table 2. The acoustic indication can be disabled by simultaneous pressinq and holding the pair of buttons (A+B) until the red LED (1) starts flashing briefly for the second time, usually in 6 s. When the red LED (1) flashes a second time release the button (B) and press it again. The acoustic indication is then disabled and confirmed by flashes of the red LED and a one beep. After this confirmation release all buttons. The acoustic indication can be enabled by repeating the procedure above. Activation is confirmed by a double flash of the red LED and a double beep. Caution: When a reaction for pressing buttons (A+B) simultaneously is set (for example a panic alarm or garage door control), it is necessary to mind that the action is performed first. Reaction for pair of buttons (segment function) • Unset / Set • Unset / Partially set • Unset / Partially set / Set . PG OFF / PG ON Table: 1. Button function options overview The JA-162J One-way two-button keypad 1/2 MMJ56104

****** Page 2 ****** The JA-162J One-way two-button keyfob LED indication table Action Activation (pressing) the button Send enrollment signal Deactivation (turn off) keyfob lock or deactivation of acoustic indication Activation (turn on) keyfob lock or activation of acoustic indication Low battery Holding the button — transmitting of maintained signal for PG copy Indication 0.5 s flash of red LED lx short acoustic si nal 1 s flash of red LED 0.5 s flash of red LED lx short acoustic signal 2x 0.5 s flash of red LED 2x short acoustic signals Short flash of red LED 3x short acoustic signals flashing 2x per 1 s lx short acoustic signal Technical specifications Compatible with. control panel FW F-Link 1.4.0+ Power - lithium battery type CR 2032 (3.0 V / 0.2 Ah) (Power supply C class according to EN 50131-6) Current consumption: - Nominal consumption - Maximal consumption Low battery voltage detection Typical battery lifetime Communication frequency RF range Dimensions Weight with no battery Classification - according to 33 mA s 2.2 v approx. 2 years (10 activations I day) 868.1 MHz approx 100 m (line of sight) 77 x 36 x 15 mm 32 g Security grade 2 / environmental class II EN 50131-1, EN 50131-3 (digital key) Table: 2. Remote control indication Battery replacement Low battery indication is signalled on the remote control after any button is pressed. The action assigned to the button is done and the red LED flashes with 3 quick beeps. Low battery information is also sent to the control panel. The remote still works as usual but the RF range goes slowly down. Low battery indication is cancelled when a new battery is inserted. To change the battery, unscrew the 2 screws from the back plastic; remove the cover with the metal strut from the housing. Then press any button a few times to discharge the rest of the energy from the capacitors and insert a new battery. Don't throw the used batten,' into the trash but take it to a suitable recycling station. The JA-162J One-way Wvo-button keypad - number of unique production codes - environment - operational temperature range - average humidity - certification body Also complies with Can be operated according to > 1 Million indoor general -looc to +400c 75 % RH, no condensation Trezor Test s.r.o. (no. 3025) ETSI EN 300 220, EN 50130-4, EN 55022, EN 60950-1 ERC REC 70-03 2/2 JABLOTRON ALARMS a.s. hereby declares that the JA-162J is in a compliance the relevant Union harmonisation legislation: Directives No: 2014/53/EU, 2014/35/EU, 2014/30/EU, 2011/65/ELJ. The original of the confomity assessment can be found at mwv.jablotron.com - Section Downloads. Note: Although this product does not contain any harmful materials we suggest you return the product to the dealer or directly to the producer after use. MMJ56104


FREE ENGLISH PDF

OPERATING INSTRUCTIONS

USER GUIDE - USER MANUAL

OWNER GUIDE - OWNER MANUAL

REFERENCE GUIDE - REFERENCE MANUAL

INSTRUCTION GUIDE - INSTRUCTION MANUAL

Leave a Reply