What are the safety precautions when installing or maintaining the equipment?
Take ESD protection measures during equipment installation and maintenance. For example, wear ESD gloves or an ESD wrist strap.
What kind of product is this?
This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
What should not be placed on the chassis?
Do not place other objects on the chassis.
What should you do to prevent eye damage from the laser beams?
Laser beams will cause eye damage. Do not look into bores of optical modules or optical fibers without eye protection.
When should you install the power cables?
Do not install power cables while the power is on.
When should you turn on the power?
Do not turn on the power until you have finished installing the chassis and connecting cables.
Where should the product not be placed?
Do not place this product in an environment with flammable or explosive gases, or smoke.
What should be avoided at the installation site?
The installation site must be free from leaking or dripping water, heavy dew, and humidity. If the relative humidity is high, use dehumidifiers or dehumidifying air conditioners.
What are the requirements for ventilation at the installation site?
The installation site must be well ventilated. Ensure that air vents on the equipment are not blocked.
What type of environment should the equipment not be installed in?
Do not install the equipment in a dusty environment.
Why is grounding the switch important?
Grounding the switch helps protect it from lightning, electromagnetic interference, and electrostatic discharge, and is the prerequisite for a PoE switch to provide power for a PD.
How much clearance should be left at the rear and both sides of the chassis?
Leave at least 50 mm clearance at the rear and both sides of the chassis for heat dissipation.
What heat dissipation modes do S series switches use?
S series switches use forced, intelligent, or natural heat dissipation mode.
How much distance should be left between switches if multiple switches are installed in a cabinet/rack?
If multiple switches are installed in a cabinet/rack, leave at least 1 U (44.45 mm) distance between each two switches. This distance is recommended for switches using forced or intelligent heat dissipation, and is required for switches using natural heat dissipation.
What should be ensured regarding the temperature and humidity at the installation site?
Ensure that the temperature and humidity at the installation site meet the switch operation requirements. For the specific requirements, see the Hardware Description for your switch on the Huawei support website.
How should Ethernet cables used outdoors be installed?
Ethernet cables used outdoors must be buried underground or routed through steel pipes to protect the switch from lightening. Do not route Ethernet cables overhead.
How should network ports be protected from lightning?
To protect network ports from lightning, use 8-line surge protectors or Huawei certified 4-line surge protectors.
How should a network port surge protector be installed?
When installing a network port surge protector, connect the IN ports to network devices and connect the OUT ports to network ports of the switch.
Which series switches cannot be desk mounted?
S5710-HI, S6700-EI and S6720-HI series switches cannot be desk mounted.
How should fanless switches be stacked?
Do not stack fanless switches on top of or closely next to each other.
What is the purpose of the security slot?
Some switch models provide a security slot ( ) near the panel on a side of the chassis. You can install a security lock (separately purchased) in this slot to protect the switch against theft.
What should be ensured before desk mounting the chassis?
Ensure that there are no flammable or explosive materials near the switch and no obstructions within 100 mm around the switch.
How is the chassis desk mounted?
- Step 1: Attach four rubber pads to the bottom.
- Step 2: Place the chassis on a desk.
- Step 3: (Optional) Install a security lock.
- Step 4: Connect the ground cable to the ground point.
Which switches cannot be wall mounted?
S3700-HI, S5700-HI, S6720S-EI, and other 420 mm or deeper switches cannot be wall mounted.
What should be done before drilling holes in a wall for wall mounting?
Before drilling holes in a wall, make sure there are no power cables in the wall to avoid electric shock.
Where can the expansion bolts be obtained?
The expansion bolts need to be purchased separately.
How is the chassis wall mounted?
- Step 1: Use M4 screws to fix the mounting brackets on both sides close to the port side.
- Step 2: Use a hammer drill with φ8 drill bit to drill holes on the wall, and fix the switch on the wall with expansion bolts.
- Step 3: Connect the ground cable to the ground point.
Which switch can be installed on the top wall?
Only the S5720-16X-PWH-LI-AC can be installed on the top wall.
Who provides the expansion bolts and top-mounting brackets for top wall mounting?
Expansion bolts and top-mounting brackets must be self-provided.
How is the chassis top wall mounted?
- Step 1: Mark the positions to drill holes according to the switch’s size and positions of top-mounting brackets.
- Step 2: Use M4 screws to attach two top-mounting brackets to the switch.
- Step 3: Use a hammer drill (with φ8 drill bit) to drill holes, and use expansion bolts to secure the switch on the top wall.
- Step 4: Connect the ground cable to the ground point.
What is the distance requirement between the port side and the interior side of the cabinet door when a chassis uses Category-6 or higher Ethernet cables?
When a chassis uses Category-6 or higher Ethernet cables, the distance between the port side and interior side of the cabinet door must be larger than or equal to 120 mm.
Can switches be installed in a 600 mm deep cabinet when they are equipped with 1150 W PoE power modules?
Switches cannot be installed in a 600 mm deep cabinet when they are equipped with 1150 W PoE power modules.
What should be done to install a 250 mm wide switch in a 19-inch cabinet?
To install a 250 mm wide switch in a 19-inch cabinet, purchase long mounting brackets.
How many screws are needed to fix each mounting bracket on the chassis for the 220 mm deep models of the S2700 and S3700 series, and the S5700-24TP-SI-AC/DC?
For the 220 mm deep models of the S2700 and S3700 series, and the S5700-24TP-SI-AC/DC, each mounting bracket needs to be fixed on the chassis with only two screws.
How many screws are needed to fix each mounting bracket on the chassis for other switch models?
For other switch models, each mounting bracket needs to be fixed with three screws.
Are the floating nuts and M6 screws delivered with the switch?
The floating nuts and M6 screws are not delivered with the switch and need to be separately purchased if needed.
What is recommended for installing the S6700-EI chassis?
S6700-EI chassis is heavy, so it is recommended that you install guide rails (separately purchased) in the cabinet to support the chassis.
What kind of cabinet/rack can S series Ethernet switches be installed in?
S series Ethernet switches can be installed in a 19-inch standard cabinet/rack.
What is required of cabinets purchased from other vendors?
Cabinets purchased from other vendors must have enough space for equipment installation.
What should be done if the distance between front and rear mounting rails is not within the required range?
If the distance between front and rear mounting rails is not within the required range, install guide rails or a tray in the cabinet/rack to support the chassis. Guide rails or trays are not delivered with the product and must be purchased separately.
What is the required distance between the front and rear mounting brackets for S5710-HI?
Ensure a distance of 418–528 mm or 545–655 mm between the front and rear mounting brackets.
What is recommended when many cables are used?
Cable management frames are recommended when many cables are used.
How should the floating nuts be arranged on the front and rear mounting rails for S5710-HI?
Leave 2 U between the floating nuts on each front mounting rail, and 1 U between those on the rear rails. Ensure the lower floating nut on each mounting rail is level with those on the other mounting rails.
How is the S5710-HI chassis installed in the cabinet?
- Step 1: Connect the ground cable to the switch.
- Step 2: Use M4 screws to attach a mounting bracket delivered with the switch to each side of the switch.
- Step 3: Install four floating nuts on the front mounting rails, two on each side.
- Step 4: Hold bottom of the chassis and push the chassis into the cabinet.
- Step 5: Use M6 screws to secure the chassis onto the cabinet/rack.
- Step 6: Connect the ground cable to the ground point on the cabinet.
What is the required distance between the front and rear mounting brackets for S5710-EI, S5720-C-EI, S5720-PC-EI, S5720-SI (420 mm depth), S5720-HI, S5730-HI, S5730-SI, S5730S-EI, S6720-SI, S6720S-SI, and S6720-EI?
Ensure a distance of 335–442 mm or 460–570 mm between the front and rear mounting brackets.
How should the floating nuts be arranged on the front and rear mounting rails for S5710-EI, S5720-C-EI, S5720-PC-EI, S5720-SI (420 mm depth), S5720-HI, S5730-HI, S5730-SI, S5730S-EI, S6720-SI, S6720S-SI, and S6720-EI?
Leave 1 U between the floating nuts on each front mounting rail, and 1 U between those on the rear rails. Ensure the lower floating nut on each mounting rail is level with those on the other mounting rails.
What is the required distance between the front and rear mounting brackets for S5731-H, S5731-H-K, S5731-S, S5731S-S, S5731S-H, S5732-H, S5732-H-K, S5735-L (420 mm depth), S5735S-L (420 mm depth), S5735-S, S5735S-S, S6720-HI, S6730-H, S6730S-H, S6730-H-K, S6730-S, and S6730S-S?
Ensure a distance of 310–351 mm, 369–410 mm, 438–479 mm, or 497–538 mm between the front and rear mounting brackets.
How should the floating nuts be arranged on the front and rear mounting rails for S5731-H, S5731-H-K, S5731-S, S5731S-S, S5731S-H, S5732-H, S5732-H-K, S5735-L (420 mm depth), S5735S-L (420 mm depth), S5735-S, S5735S-S, S6720-HI, S6730-H, S6730S-H, S6730-H-K, S6730-S, and S6730S-S?
Leave 1 U between the floating nuts on each front mounting rail, and 1 U between those on the rear rails. Ensure the lower floating nut on each mounting rail is level with those on the other mounting rails.
Where can information about the power module supported by a specific model be found?
For information about the power module supported by your model, see Power Module in the Hardware Description of your switch on the Huawei support website.
Are the power modules hot swappable?
All the power modules are hot swappable (except the 870 W PoE power module).
How should a power module be installed?
When installing a power module, slowly push it into the slot. If you feel resistance or find the module inclined, pull the module out and push it into the slot again. Do not push the module with force; otherwise, the connectors on the module and backplane may be damaged.
What should be done if only one power module is installed?
If only one power module is installed, install a power module filler panel in the empty power module slot.
What is recommended for enhanced power reliability?
It is recommended that you install two power modules in a switch to enhance power reliability if the switch supports double power modules.
Where can information about the cards supported by a specific model be found?
For information about the cards supported by your model, see Cards in the Hardware Description of your switch on the Huawei support website.
Which switch models do not support hot swappable cards?
Only switch models S5700-SI, S5710-LI, and S5700-EI do not support hot swappable cards.
Can cards that do not support hot swappable be installed when the switch is running?
Cards that do not support hot swappable cannot be installed when the switch is running. You must power off the switch, install the cards, and then power on the switch to activate the cards.
What must be done to use a front 4xGE or 4x10GE optical interface card on the S5700-SI, S5710-LI and S5700-EI?
To use a front 4xGE or 4x10GE optical interface card on the S5700-SI, S5710-LI and S5700-EI, you must also install an extended rear card ES5D00ETPB00. Otherwise, only two ports instead of four ports on this optical interface card are available.
How should a card be installed?
When installing a card, slowly push it into the slot. If you feel resistance or find the card inclined, pull the card out and push it into the slot again. Do not push the card with force; otherwise, the connectors on the card and backplane may be damaged.
What should be done with vacant slots?
Install filler panels in vacant slots.
How are cables connected?
- Step 1: Use a Phillips screwdriver to loosen the captive screw on the filler panel.
- Step 2: Pull the filler panel out by the captive screw. Keep the filler panel for future use.
- Step 3: Turn the ejector lever of the card 45 degrees outward. Push the card into the chassis with your thumbs (below the captive screws), until the screw on the front panel is completely in the chassis. Front cards for the S3700-HI, S5700-HI, and S5710-HI have no screws, but the installation method is the same.
- Step 4: Rotate the ejector lever inward to lock the card after the screw is completely in the chassis.
- Step 5: Use the Phillips screwdriver to fasten the captive screws.
What type of Ethernet cable should be chosen for an electrical port based on port speed?
Choose an Ethernet cable for an electrical port depending on the port speed required:
- 2.5 Gbit/s: Ethernet cable of Cat5e or higher category
- 5 Gbit/s: shielded cable of Cat5e or higher category (unshielded cable not recommended)
- 10 Gbit/s: shielded cable of Cat6a or higher category
Can the Mini USB port and console port be used together?
Some models provide a Mini USB port to connect to a console for onsite configuration. The Mini USB port and console port cannot be used together. Select either of them according to your needs. When both the two ports are connected, only the Mini USB port is active.
Should the switch be grounded?
The switch must be reliably grounded.
How should the ground cable be attached?
Attach the M4 lug to the switch and the M6 lug to the ground point.
What must optical fibers be used with?
Optical fibers must be used with optical modules.
What should the bend radius of optical fibers be?
The bend radius of optical fibers must be larger than 40 mm.
What is the distance requirement between power cables and signal cables?
Power cables must be more than 10 cm away from signal cables.
What type of AC power cables should be used?
If your switch uses AC power supply, use AC power cables in compliance with local standards.
What should be ensured when using DC power supply?
If your switch uses DC power supply, ensure that the positive and negative cables are connected to the positive and negative poles correctly.
How can a PC be directly connected to the ETH management interface to log in to the device for the first time?
The default IP address of the ETH management interface on a device is 192.168.1.253/24. Directly connect the PC to the ETH management interface on the device using network cables.
What is the procedure for logging in to the switch for the first time using the web system (Mode 1)?
- Step 1: Directly connect the PC to the ETH management interface to log in to the device for the first time.
- Step 2: Configure an IP address for the computer, which is in the same network segment as the default IP address of the switch.
- Step 3: Start the web browser on the computer, enter https://192.168.1.253 in the address box, and press Enter to display the initial login page. Enter the default user name admin and default password admin@huawei.com and select the language on the login page. Then click GO or press Enter.
What are the descriptions of the configuration items for the initial login page?
| Configuration Item | Description |
|---|---|
| Management IP Address | Mandatory. Enter the management IP address of the switch, in dotted decimal notation. |
| Mask | Mandatory. Select a subnet mask from the drop-down list box. |
| Old Password | Mandatory. Enter the old password for the default web user. |
| WEB User Password | Mandatory. Enter a new password for the default web user. To ensure password strength, the password must contain at least two types of the following: lowercase letters, uppercase letters, digits, and special characters (such as ! $ # %), and cannot contain any space or single quotation mark. |
| Confirm Password | Mandatory. Enter the new password again. |
| WEB User Level | Optional. Select a user level from the drop-down list box. The user of level 3 or higher has management rights. |
What is the procedure for logging in to the switch for the first time using the web system (Mode 2)?
- Step 1: If the device has only the ETH management interface, connect the PC to the ETH management interface using network cables. Press and hold down the MODE button for 6 seconds or longer. When all indicators on the device are steady green, the device enters the initial configuration mode, and the default IP address configured for the ETH management interface of the device is 192.168.1.253/24.
- Step 2: If the device has Ethernet interfaces, connect the PC to any Ethernet interface excluding the ETH management interface using network cables. Press and hold down the MODE button for 6 seconds or longer. When all indicators on the device are steady green, the device enters the initial configuration mode, and the default IP address configured for Vlanif1 of the device is 192.168.1.253/24.
When can users log in to a device for the first time using the web system?
Users can log in to a device for the first time using the web system only when the device is in factory default state. In this case, do not log in to the device through the console interface, because any operation on the console interface leads to the failure of the first login using the web system.
What happens if the configuration is not saved within 10 minutes after entering the initial configuration mode?
If you do not save the configuration in 10 minutes after entering the initial configuration mode, the system will exit from this mode and restore the factory settings.
What might happen if the device in the factory settings has just started or has been configured through the console interface when users press and hold down the MODE button for 6 seconds?
If the device in the factory settings has just started or has been configured through the console interface when users press and hold down the MODE button for 6 seconds, the device may fail to enter the initial configuration state. When all indicators blink fast for 10s, the device restores to the factory default state.
What happens if you have logged in to the device for the first time by holding down the MODE button for 6 seconds or longer and saved the configuration?
If you have logged in to the device for the first time by holding down the MODE button for 6 seconds or longer and saved the configuration, default configurations of the ETH management interface are cleared and you cannot log in to the device for the first time through the ETH management interface. You are advised to preferentially log in to the device for the first time through the ETH management interface.
What should be done to save the configuration and exit the initial login page?
Click Apply to save the configuration. When you exit from the initial login page, either of the following situations will occur depending on the management IP address you configured:
- If the management IP address is in the same network segment as 192.168.1.253/24, the system jumps to the web login page directly.
- If the management IP address is not in the same network segment as 192.168.1.253/24, you cannot log in to the switch again using the web system. You need to configure another IP address for your computer to make the computer and switch reachable from each other.
What function has been added to the web EasyOperation edition since V200R010?
The Quick Config function has been added to the web EasyOperation edition since V200R010. You can quickly finish the configurations of VLAN isolation and interconnection by selecting the Switching and Routing options.
How can you maintain the switch after logging in for the first time?
Now, you can log in to the switch using the web system, Telnet, or STelnet to maintain the switch.
Which switch series also support login through the Mini USB port?
The S5700-LI, S5700S-LI, S5710-EI, S5720-EI and S5720-HI series switches also support login through the Mini USB port.
Which S5720-EI models do not have a Mini USB port?
In the S5720-EI series, the S5720-50X-EI-AC, S5720-50X-EI-DC, S5720-50X-EI-46S-AC and S5720-50X-EI-46S-DC models do not have a Mini USB port.
Is the console cable delivered with the switch?
The console cable is not delivered with the switch and needs to be separately purchased if needed.
How should third-party terminal simulation software be installed on the PC?
Install third-party terminal simulation software on the PC by referring to user manual or online help.
How is the switch logged in to through the console port?
- Step 1: Use a console cable to connect the switch to a PC.
- Step 2: Start the terminal simulation software, create a connection, select a serial port, and set communication parameters in consistent with the default configuration of the switch’s console port, as listed below:
- Transmission rate: 9600
- Data bit (B): 8
- Parity bit: None
- Stop bit (S): 1
- Flow control mode: None
- Step 3: Press Enter in subsequent steps until the following information is displayed on the terminal simulation software, and then enter a password. The default user name for the first login is admin and the default password is admin@huawei.com. You must change the password after login.
Is the password entered in interactive mode displayed on the screen?
The password entered in interactive mode is not displayed on the screen.
What happens to the authentication password if the authentication mode and password are not changed after entering the user view?
If you do not change the authentication mode and password after entering the user view, the authentication password used for next login is the one configured during the first login.
Where can product documentation be obtained?
Log in to Huawei enterprise technical support website (http://support.huawei.com/enterprise), and select a specific product model and version to find its documentation.
Where can technical support be obtained?
Log in to Huawei enterprise support community (https://forum.huawei.com/enterprise/en/index.html) and post your questions in the community.
CLICK HERE TO DOWNLOAD HUAWEI S6700 (01) PDF MANUAL