Free English HUAWEI CLOUDENGINE CE7800 (01) PDF document. Download the PDF, use the online viewer, or browse the FAQs for easy troubleshooting.


CLICK HERE TO DOWNLOAD HUAWEI CLOUDENGINE CE7800 (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

What is included in the packing list for the HUAWEI CLOUDENGINE CE7800 series switch?

The packing list includes:

Chassis:

Chassis (with the product model on the nameplate)

If the switch you ordered has built-in power modules and fan modules, they are installed in the chassis before delivery by default.

Installation accessory package:

Chassis ground cable

Console cable (only for CE8860, CE8861, CE8868)

Quick Start Guide

Warranty Card

Mounting brackets and guide rails

Floating nuts

M4 screws

M6 screws

NOTE: The numbers and types of items in the installation accessory package differ for different product models.


What are the safety guidelines for the HUAWEI CLOUDENGINE CE7800 switch?

To ensure personal and equipment safety, observe all safety precautions on the equipment and in this document. Follow all safety precautions and instructions provided. The safety precautions outlined are requirements of Huawei and do not include general safety requirements. Huawei is not liable for any consequence that results from violation of regulations pertaining to safe operations or safety codes pertaining to design, production, and equipment use.

WARNING

Laser beams will cause eye damage. Do not look into bores of optical modules or optical fibers without eye protection.

Do not install power cables while the power is on.

Do not turn on the power until you have finished installing the chassis and connecting cables.

CAUTION

This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

Take ESD protection measures during equipment installation and maintenance. For example, wear ESD gloves or an ESD wrist strap.

Do not place other objects on the chassis.


What are the site environment requirements for the HUAWEI CLOUDENGINE CE7800 switch?

Do not place this product in an environment with flammable or explosive gases, or smoke.

The installation site must be free from leaking or dripping water, heavy dew, and humidity. If the relative humidity is high, use dehumidifiers or dehumidifying air conditioners.

The installation site must be well ventilated. Ensure that air vents on the equipment are not blocked.

Leave at least 50 mm clearance at the rear and both sides of the chassis for heat dissipation.

Ensure that the temperature and humidity at the installation site meet the switch operation requirements. For the specific requirements, see the Hardware Description for your switch.


What are the chassis dimensions for the HUAWEI CLOUDENGINE CE7800 series switch?

Series Dimensions (W x D x H)
CE8800 CE8860, CE8861, CE8868, CE8850-64CQ-EI: 442.0 mm × 600.0 mm × 88.1 mm (about 2U)
CE8850-32CQ-EI: 442.0 mm × 420.0 mm × 43.6 mm (about 1U)
CE7800 442.0 mm x 607.0 mm x 43.6 mm (about 1U)
CE6800 CE6810-32T16S4Q-LI, CE6851-48S6Q-HI, CE6855-48S6Q-HI, CE6856-48S6Q-HI, CE6857-48S6CQ-EI, CE6860, CE6865, CE6870, CE6880, CE6881, CE6820, CE6863: 442.0 mm x 420.0 mm x 43.6 mm (about 1U)
Other CE6800 models: 442.0 mm × 600.0 mm × 43.6 mm (about 1U)
CE5800 442.0 mm x 420.0 mm x 43.6 mm (about 1U)

What are the cabinet requirements for installing a HUAWEI CLOUDENGINE CE7800 switch?

The widths of CE8800, CE7800, CE6800, and CE5800 series switches comply with industry standards. Therefore, these switches can be installed in a standard 19-inch cabinet/rack complying with IEC297.

The CE7800 can be installed in an 800 mm or deeper cabinet.

On a switch, the side with power modules and fan modules is the power supply side, and the side with service ports is the port side. To leave sufficient cabling space, ensure that the distances from the port side and power supply side to the interior side of the cabinet doors are at least 130 mm and 70 mm respectively.

The cabinet must have a reliable ground point to ground the switch.

If the CE7800 series switches are installed in the same cabinet with a CE12800 switch, keep a distance of 700 mm to 800 mm between the front and rear mounting rails.


How do I install the chassis of a HUAWEI CLOUDENGINE CE7800 switch in a cabinet?

Before You Start

Determine the directions of the port side and power supply side according to actual situations. If the switch needs to connect to servers in the same cabinet, make port sides of the switch and servers face the same direction to facilitate cable connections. Whether the mounting brackets should be installed near the port side or power supply side depends on the direction in which the chassis is installed. Ensure that the rear mounting brackets will not touch the cabinet door. The figures here are for reference only.

If the distance between front and rear mounting rails is not within the required range, install guide rails or a tray (self-provided) in the cabinet/rack to support the chassis.

The following table shows the supported mounting hardware for the CE7800 (600 mm deep) model:

Mounting Brackets and Guide Rails CE7800&6800 (600 mm deep)
Mounting bracket A Supported
Mounting bracket B Not supported
Mounting bracket C Supported
Guide rail E Supported
Guide rail F Not supported

Installation Procedure

Step 1: Measure the distance between the front and rear mounting rails. The type and installation method of mounting brackets and matching guide rails vary depending on this distance.

Step 2: Fix mounting brackets to the switch with M4 screws. For the CE7800 (600mm deep), the bracket combinations depend on the measured distance:

493 mm – 548 mm: Use Mounting bracket A + Mounting bracket C + Guide rail E. Note: If the cabinet is 800 mm deep, mounting bracket C will touch the cabinet door. Do not close the door at this side.

549 mm – 551 mm: Use Mounting bracket A + Mounting bracket C + Guide rail E. Note: Install mounting bracket C in mounting holes at the middle of the chassis.

552 mm – 680 mm: Use Mounting bracket A + Mounting bracket C + Guide rail E. Note: If the cabinet is 800 mm deep, mounting bracket C will touch the cabinet door. Do not close the door at this side.

681 mm – 815 mm: Use Mounting bracket A + Mounting bracket C + Guide rail E.

Step 3: Install eight floating nuts on the front and rear mounting rails, two on each mounting rail.

Step 4: Connect the ground cable to the chassis ground point and place the other end on top of the chassis.

Step 5: Secure guide rails on the front mounting rails with M6 screws.

Step 6: Hold the bottom of the chassis with both hands, align the mounting brackets with the guide rails, and slowly slide the chassis into the cabinet.

Step 7: Secure the chassis onto the cabinet with M6 screws.

Step 8: Connect the ground cable to the ground point on the cabinet.


How do I select and install power and fan modules for the HUAWEI CLOUDENGINE CE7800 switch?

Selecting Power Modules and Fan Modules

CAUTION

The switch must use the power modules and fan modules matching the product model.

The power modules and fan modules used in the switch must have the same airflow direction.

Power modules with different airflow directions or power values, AC and DC power modules, or fan modules with different airflow directions cannot be used in the same chassis.

Airflow Types:

Front-to-back airflow: Power modules and fan modules with front-to-back airflow are identified by an “AIR IN” flag. Air flows from the power supply side to the port side.

Back-to-front airflow: Power modules and fan modules with back-to-front airflow are identified by an “AIR OUT” flag. Air flows from the port side to the power supply side.

Installing Power Modules and Fan Modules into the Chassis

Before You Start

If the switch is delivered with the power modules and fan modules installed in the chassis, you do not need to install them again.

Before installing a power module or fan module, remove the filler panel in the slot.

If only one power module is used, install a filler panel in the other power module slot.

To ensure normal operation, the switch must have two normally running fan modules.

Do not remove the two fan modules from the chassis simultaneously. Replace a fan module within 3 minutes.

Installation Procedure

Power modules fixed using a captive screw and a lock are installed differently. Power modules and fan modules are hot-pluggable. A fan module is installed the same way as a power module fixed with captive screws.

For a power module secured by a captive screw:

Step 1: Insert the power module into a power slot.

Step 2: Tighten the captive screw on the power module panel.

For a power module secured by a lock:

Insert the power module into a power slot. When the power module is completely seated in the slot, the lock is locked automatically.


What should I know before connecting cables to my HUAWEI CLOUDENGINE CE7800 switch?

Ground cable:

The switch must be reliably grounded.

Attach the M4 lug to the switch and the M6 lug to the ground point.

Ethernet cable:

Category 5E or higher category Ethernet cables are recommended for GE electrical ports.

Category 6A shielded or higher category Ethernet cables are recommended for 10GE electrical ports.

To protect the switch from lightning, route outdoor cables underground or in steel pipes. Do not route cables aerially.

Optical fiber:

Optical fibers must be used with optical modules. Connectors of fibers and cables must be clean.

Cover idle optical ports with dust plugs. All optical ports on a newly delivered switch are covered with dust plugs.

The bend radius of optical fibers must be larger than 40 mm.

10GE optical ports use SFP/SFP+ optical modules and optical fibers, SFP+ AOC cables, or SFP+ copper cables.

25GE optical ports use SFP/SFP+ optical modules and optical fibers, SFP+ AOC cables, SFP+ copper cables, SFP28 optical modules and optical fibers, SFP28 AOC cables or SFP28 copper cables.

40GE optical ports use QSFP+ optical modules and optical fibers, QSFP+ AOC cables, or QSFP+ copper cables.

100GE optical ports use QSFP+/QSFP28 optical modules and optical fibers, QSFP+/QSFP28 AOC cables, or QSFP+/QSFP28 copper cables.

Country-specific AC power cable:

Power cables must be more than 10 cm away from signal cables.

The country-specific AC power outlet must have a current rating of 10 A and comply with local standards.

The AC power cable must be locked using a locking strap or bundled to the power module handle using a velcro strap.

C13 straight female to C14 straight male AC power cable:

Choose this type of power cable when the switch uses AC power modules and receives power from an AC PDU, or when it uses 600 W/1200 W AC&240 V DC power modules and receives power from a 240 V high-voltage DC PDU or power distribution box.

If a 240 V high-voltage DC power distribution box is used, make OT or cord end terminals for the cable. Cut the C14 straight male connector off and crimp OT or cord end terminals on the bare wires. Connect the brown wire to a negative terminal on the DC power distribution box, the blue wire to a positive terminal, and the yellow-green wire to a protection ground.

Notice the positive and negative tags on DC power cables and power terminals.

380 V high-voltage DC power cable:

Choose this type of power cable when the switch uses high-voltage DC power modules and receives power from a 380 V high-voltage DC power distribution box or frame.

The delivered cable has bare wires on one end, and OT or cord end terminals must be made for them onsite. Connect the brown wire to the positive pole, blue wire to negative pole, and yellow-green wire to protection ground.

The power cable must be locked using a locking strap or bundled to the power module handle using a velcro strap.


How are the various cables connected to the HUAWEI CLOUDENGINE CE7800 switch?

Item Connect To
Ground cable Protection ground
Ethernet cable Switch or computer
Optical fiber, AOC cable, or Copper cable Upstream network device or stacked switch
Ethernet cable (Management) Operation terminal (usually a PC)
Console cable Operation terminal (usually a PC)
USB port USB flash drive
Country-specific AC power cable Country-specific AC power outlet
C13 straight female to C14 straight male AC power cable AC PDU, 240 V high-voltage DC PDU or power distribution box
DC power cable (for 350 W or 1200 W DC power modules) DC power distribution box
380 V high-voltage DC power cable 380 V high-voltage DC power distribution box or power distribution frame

How do I log in to my HUAWEI CLOUDENGINE CE7800 switch through the console port?

Before You Start

Install third-party terminal simulation software on the PC by referring to user manual or online help.

Login Procedure

Step 1: Use a console cable to connect a PC to the console port of the switch.

Step 2: Start the terminal simulation software, create a connection, select a serial port, and set communication parameters:

Transmission rate: 9600

Data bit (B): 8

Parity bit: None

Stop bit (S): 1

Flow control mode: None

Step 3: Press Enter, and then enter a password as prompted. The configured password will be saved in the system.

An initial password is required for the first login via the console. If prompted to continue, enter ‘y’. You will then be prompted to configure a login password.

Notes:

By default, the system will start the zero-touch provisioning (ZTP) process. To cancel this process, press Ctrl+C.

The password entered in interactive mode is not displayed on the screen.

If password authentication is not configured, you do not need to enter a password, but this brings security risks. Password authentication is recommended.

The password is a string of 8 to 16 case-sensitive characters. It must contain at least two types of the following: uppercase letters, lowercase letters, digits 0 to 9, and special characters excluding question mark (?) and spaces.

After a login password is configured, this password will be required upon next login if password authentication is used on this user interface.

If you forget the login password, see the Troubleshooting section to restore the password.

Now you can configure the switch on the command line interface.


How do I log in to my HUAWEI CLOUDENGINE CE7800 switch through the Mini USB port?

Before You Start

This login method is supported on specific models: CE8860, CE8861, CE8868, CE8850-64CQ-EI, CE6850HI, CE6850U-HI, CE6855-48T6Q-HI, CE6856-48T6Q-HI and CE6875EI.

Install third-party terminal simulation software on the PC by referring to user manual or online help.

Login Procedure

Step 1: Use a Mini USB cable to connect a PC to the Mini USB port of the switch.

Step 2: Download the Mini USB driver CE_MiniUSB_driver. The Mini USB driver can only be used on Windows XP, Vista, and 7 operating systems.

Step 3: Install the Mini USB driver on the PC. Right-click My Computer and choose Manage > Device Manager > Port (COM and LPT). “TUSB3410 Device” is the Mini USB driver that you have installed. If “TUSB3410 Device” is not displayed in the device manager, reinstall the driver or use another Mini USB cable to connect the PC to the switch.

Step 4: Start the terminal simulation software, create a connection, and set communication parameters for the Mini USB port.

Transmission rate: 9600

Data bit (B): 8

Parity bit: None

Stop bit (S): 1

Flow control mode: None

Step 5: Press Enter, and then enter a password as prompted. The configured password will be saved in the system. The information displayed and notes about the operation are the same as for logging in through the console port.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD HUAWEI CLOUDENGINE CE7800 (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.