What are the important safety instructions for the HERCULES HE028?
When using the HERCULES HE028, basic precautions should always be followed to reduce the risk of fire, electric shock, or injury. READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE.
1. Do not leave appliance when plugged in. Unplug from outlet when not in use and before servicing.
2. Do not expose to rain. Store indoors.
3. Do not allow to be used as a toy. Close attention is necessary when used by or near children.
4. Use only as described in this manual. Use only manufacturer’s recommended attachments.
5. Do not use with damaged cord or plug. If appliance is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, return it to a service center.
6. Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or corners. Do not run appliance over cord. Keep cord away from heated surfaces.
7. Do not unplug by pulling on cord. To unplug, grasp the plug, not the cord.
8. Do not handle plug or appliance with wet hands.
9. Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint, hair, and anything that may reduce air flow.
10. Keep hair, loose clothing, fingers, and all parts of body away from openings and moving parts.
11. Turn off all controls before unplugging.
12. Use extra care when cleaning on stairs.
13. Do not use to pick up flammable or combustible liquids, such as gasoline, or use in areas where they may be present.
14. Connect to a properly grounded outlet only. See Grounding Instructions.
15. Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes.
16. Do not use without dust bag and/or filters in place.
17. Dry your hands and feet before touching plug or switch.
18. Do not plug in power tool while wet vacuuming.
19. Do not continue to use the vacuum when the tank is full of liquid.
20. Do not use to pick up water from containers, i.e., sinks, tubs, barrels, etc.
21. Stay alert, watch what you are doing and use common sense when operating an appliance. Do not use an appliance while you are tired or under the influence of drugs, alcohol or medication. A moment of inattention while operating appliances may result in serious personal injury.
22. Maintain labels and nameplates on the appliance. These carry important safety information. If unreadable or missing, contact Harbor Freight Tools for a replacement.
23. People with pacemakers should consult their physician(s) before use. Electromagnetic fields in close proximity to heart pacemaker could cause pacemaker interference or pacemaker failure.
24. The warnings, precautions, and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur. It must be understood by the operator that common sense and caution are factors which cannot be built into this product, but must be supplied by the operator.
What are the grounding instructions for the HERCULES HE028?
The HERCULES HE028 must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and grounding plug. The plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING: Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the appliance – if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
This appliance is for use on a nominal 120-V circuit and has a grounding attachment plug that looks like the 125 VAC 3-Prong Plug. Make sure that the appliance is connected to an outlet having the same configuration as the plug. No adaptor should be used with this appliance.
To reduce the risk of electric shock, this appliance has a polarized plug (one blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.
What are the product specifications for the HERCULES HE028?
| Electrical Rating | 120V / 60Hz / 11.5A VC motor: 11.5A; 15A Max with tool |
| Tank Capacity | 12 Gallons |
FOR HOUSEHOLD USE ONLY.
What are the main components of the HERCULES HE028 Dust Extractor?
The main components of the HERCULES HE028 are:
1. Handle
2. Power Switch
3. Suction Control Knob
4. 120VAC Outlet
5. Automatic Filter Cleaning Button
6. Vacuum Port
7. Accessory Bag
8. Floor Nozzle
9. Crevice Nozzle
10. Dust Bag
11. Hose
12. Extension Wands
13. Elbow Wand
14. Power Tool Dust Adaptor
15. Round Brush
16. HEPA Filters
How do I assemble the HERCULES HE028?
1. Pull the Clips outward, then remove the Power Head by its Handle.
2. Set up for either dry or wet vacuuming (see specific instructions for each).
3. Replace the Power Head with the Power Switch facing forward. Secure with the Clips.
4. Insert the end of the Hose into the Vacuum Port and rotate until it is locked in place.
5. Add Extension Wand(s) and Nozzles as needed.
How do I set up the HERCULES HE028 for dry vacuuming?
a. Slide the HEPA Filters over the Cage.
b. Secure the filters by turning them clockwise until tight. Do not use excessive force.
c. When vacuuming fine dust, install the Dust Bag by placing it inside the Tank and connecting it to the Vacuum Port.
How do I set up the HERCULES HE028 for wet vacuuming?
For wet vacuuming, you must remove the Filters and Dust Bags from the HERCULES HE028.
How do I attach a power tool to the HERCULES HE028 Dust Extractor?
There are two methods for attaching a power tool:
a. Attach the power tool to the Step Adapter on the hose, OR
b. Remove the Step Adapter from the Hose and attach the Power Tool Adapter to the Hose. Then connect the power tool to the adapter.
What is the recommended minimum wire gauge for extension cords for the HERCULES HE028?
Make sure your extension cord is in good condition and heavy enough to carry the current your product will draw. An undersized cord will cause a drop in line voltage resulting in loss of power and overheating. The table below shows the correct size to use depending on cord length and nameplate ampere rating. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.
| NAMEPLATE AMPERES (at full load) | EXTENSION CORD LENGTH | |||
|---|---|---|---|---|
| 25′ | 50′ | 100′ | 150′ | |
| 0 – 6 | 18 | 16 | 16 | 14 |
| 6.1 – 10 | 18 | 16 | 14 | 12 |
| 10.1 – 12 | 16 | 16 | 14 | 12 |
| 12.1 – 16 | 14 | 12 | Do not use. | |
How do I operate the HERCULES HE028 for vacuuming?
WARNING: To prevent serious injury from accidental operation, turn the Switch off and unplug the power cord from its electrical outlet before removing the Power Head.
1. Ensure you are using a proper extension cord if needed.
2. Turn the Power Switch OFF. Plug the Power Cord into a grounded 120VAC electrical outlet.
3. Open the Quick Clips, adjust the Handle, then close the Quick Clips.
4. Lock the Swivel Casters.
5. Hold the Hose securely. Turn the Power Switch ON.
6. To extend the life of the HEPA Filters, turn on Automatic Cleaning. There will be intermittent pulsing as dust particles are distributed to the bottom of the tank. When vacuum function decreases, clean and replace the HEPA Filters and replace the Dust Bag.
7. Adjust the Suction Control Knob as needed.
How do I connect a power tool for dust collection with the HERCULES HE028?
a. Turn the Power Switch on the HERCULES HE028 OFF.
b. Connect the power tool’s hose to the Dust Extractor.
c. Plug the power tool into the 120VAC Outlet on the Dust Extractor.
d. Turn the Power Switch on the HERCULES HE028 to the power tool position. Turn on the power tool to start the Dust Collector.
Note: The Vacuum will start after the power tool is turned on and will remain on for 15-30 seconds after the power tool is turned off.
e. When finished, turn the Power Switch OFF. Unplug the power tool and the Dust Extractor.
What are the instructions for wet vacuuming with the HERCULES HE028?
WARNING! TO PREVENT SERIOUS INJURY FROM ELECTRIC SHOCK: Dry your hands and feet before touching the plug or switch. Do not continue to use the vacuum when the tank is full of liquid. Do not plug in a power tool while wet vacuuming.
1. Make sure Automatic Filter Cleaning is off.
2. IMPORTANT! Leave a gap at the tip of the nozzle opening to allow air inflow. Do not immerse the nozzle completely in liquid.
What should I do when the motor sound becomes higher in pitch during wet vacuuming with the HERCULES HE028?
When the motor sound becomes higher in pitch, it indicates the tank is full and the float is closing off the motor intake. You must act IMMEDIATELY:
a. DRY YOUR HANDS AND FEET,
b. Turn the Vacuum OFF,
c. Unplug the Power Cord,
d. Empty the Tank.
To prevent accidents, after emptying the tank, DRY YOUR HANDS AND FEET, turn off the appliance and unplug it. Empty and clean the Tank, dry the Tank, clean the Filter (see Cleaning Filters), then store the appliance indoors out of children’s reach.
What are the general maintenance instructions for the HERCULES HE028?
WARNING: To prevent serious injury from accidental operation, turn the Power Switch off and unplug the appliance from its electrical outlet before performing any procedure in this section. Do not use damaged equipment. If abnormal noise or vibration occurs, have the problem corrected before further use.
1. BEFORE EACH USE, inspect the general condition of the appliance. Check for:
• loose hardware
• misalignment or binding of moving parts
• air leakage on the Tank or Power Head connection
• cracked or broken parts
• damaged electrical wiring
• any other condition that may affect its safe operation.
2. AFTER USE, wipe external surfaces of the appliance with a clean cloth. Store in an indoor dry area out of reach of children.
3. All parts are permanently lubricated. Do not use additional lubrication.
4. WARNING! TO PREVENT SERIOUS INJURY: If the supply cord of this appliance is damaged, it must be replaced only by a qualified service technician.
How do I clean the HEPA filters on the HERCULES HE028?
To ensure proper operation, clean the Filter regularly. A torn Filter should be replaced.
1. Remove Filters.
2. Tap or shake Filters into a waste can.
3. If needed, flush with plain water. Allow the Filter to dry for at least 24 hours before replacing. DO NOT USE COMPRESSED AIR.
WARNING! TO PREVENT SERIOUS INJURY: Installing a wet Filter will increase the risk of electric shock and may damage the vacuum.
4. Replace Filters.
What is the parts list for the HERCULES HE028?
| Part | Description | Qty | Part | Description | Qty |
|---|---|---|---|---|---|
| 1 | Power Head Handle | 1 | 38 | Flat Cage | 2 |
| 2 | Head Cover | 1 | 39 | Filter | 2 |
| 3 | Baffle | 1 | 40 | Wheel Cap | 2 |
| 4 | Outlet Muffler Sponge | 1 | 41 | Wheel | 2 |
| 5 | Outlet Cover A | 1 | 42 | Axle | 1 |
| 6 | Intake Muffler Sponge | 2 | 43 | Wheel Support | 1 |
| 7 | Air Duct Muffler Sponge | 1 | 44 | Sleeve | 2 |
| 8 | Motor Muffler Sponge | 1 | 45 | Right Sleeve Assembly | 1 |
| 9 | Motor Assembly | 1 | 46 | Handle | 1 |
| 10 | Air Duct Seal Ring | 1 | 47 | Power Cord Hanger | 1 |
| 11 | O-ring | 1 | 48 | Left Sleeve Assembly | 1 |
| 12 | Motor Sealing Gasket | 1 | 49 | Tank | 1 |
| 13 | Pull Ring | 1 | 50 | Clip | 2 |
| 14 | Elastic Strap | 1 | 51 | Vacuum Port Cover | 1 |
| 15 | Ring Cover | 1 | 52 | Vacuum Port | 1 |
| 16 | Ring Cover Seal | 1 | 53 | Hose W/Step Adapter | 1 |
| 17 | Ground Lug | 1 | 54 | Foot Support | 2 |
| 18 | Antistatic Copper Sheet | 1 | 55 | Locking Swivel Caster | 2 |
| 19 | Valve Assembly | 1 | 56 | Handle Dam-Board | 2 |
| 20 | Power Cord | 1 | 57 | Accessory Bag | 1 |
| 21 | Wire Ramp | 1 | 58 | Extension Wands | 2 |
| 22 | Switch Clamp | 1 | 59 | Floor Nozzle | 1 |
| 23 | Servo Motor Power Switch | 1 | 60 | Elbow Wand | 1 |
| 24 | Cooling Air Outlet Muffler Sponge | 1 | 61 | Crevice Nozzle | 1 |
| 25 | Outlet Cover B | 1 | 62 | Power Tool Adaptor | 1 |
| 26 | Top Cover Muffler Sponge | 1 | 63 | Disposable Bag | 1 |
| 27 | PCBA | 1 | 64 | Round Brush | 1 |
| 28 | Switch Indicator PCBA | 1 | 101 | Screw ST 5.28*25 | 14 |
| 29 | Control Panel | 1 | 102 | Screw ST 4.55*19 | 15 |
| 30 | Suction Control Knob | 1 | 103 | Screw ST 3.12*12 | 2 |
| 31 | Power Switch | 1 | 104 | Screw ST 3.63*13 | 7 |
| 32 | PTA Assembly | 1 | 105 | Screw ST 4.55*16 | 12 |
| 33 | Valve Seat Seal Gasket | 1 | 106 | Screw ST 3.63*10 | 6 |
| 34 | Seal Strip | 1 | 107 | Nut | 2 |
| 35 | Filter Mount | 1 | 108 | Spring Washer | 2 |
| 36 | Float Seal | 2 | 109 | Screw ST 4.55*25 | 4 |
| 37 | Float | 2 |
How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.
CLICK HERE TO DOWNLOAD HERCULES HE028 (01) PDF DOCUMENT