What should I do before operating the GUARDIAN TECHNOLOGIES GERMGUARDIAN AC5350 air purifier?

1. Select a firm, level and flat location for the GUARDIAN TECHNOLOGIES GERMGUARDIAN AC5350 air purifier.

2. For proper air flow, locate the unit at least 1 foot from any wall or furniture.

3. Make sure none of the grills are blocked.

4. Plug the power cord into a 120V AC outlet.


How do I turn on the GUARDIAN TECHNOLOGIES GERMGUARDIAN AC5350 air purifier?

Turn unit power ON.


What are the fan speed modes for the GUARDIAN TECHNOLOGIES GERMGUARDIAN AC5350 air purifier?

Select fan speed MODE 1 – 5:

1 = low, ultra quiet sleep mode

5 = high speed allergen control – Default setting is 5


How can I use the UV-C feature on the GUARDIAN TECHNOLOGIES GERMGUARDIAN AC5350 air purifier?

Select UV-C ON or OFF using UV-C Mode Button.


How do I set the TIMER function on the GUARDIAN TECHNOLOGIES GERMGUARDIAN AC5350 air purifier?

If you prefer to run the GUARDIAN TECHNOLOGIES GERMGUARDIAN AC5350 air purifier for a specific number of hours, you can select between 1 and 8 hours on the display using the TIMER SET Button.


What indicates that it is time to replace the HEPA filter on the GUARDIAN TECHNOLOGIES GERMGUARDIAN AC5350 air purifier?

The Replace HEPA light on the control panel will illuminate and flicker indicating that it is time to replace your filter.


How do I reset the system after replacing the HEPA filter on the GUARDIAN TECHNOLOGIES GERMGUARDIAN AC5350 air purifier?

Replace the filter according to directions then press and hold the Timer Button button for 3 seconds to reset the system.


What indicates that it is time to replace the UV bulb on the GUARDIAN TECHNOLOGIES GERMGUARDIAN AC5350 air purifier?

The circular blue light on the front panel of the GUARDIAN TECHNOLOGIES GERMGUARDIAN AC5350 air purifier will flicker when it is time to replace the bulb.


How do I reset the system after replacing the UV bulb on the GUARDIAN TECHNOLOGIES GERMGUARDIAN AC5350 air purifier?

Replace the bulb according to directions then press and hold UV Mode button for 3 seconds to reset the system.


How can I turn off the control panel beep/sound on the GUARDIAN TECHNOLOGIES GERMGUARDIAN AC5350 air purifier?

The sound emitted from pressing the buttons on the control panel can be turned off/on by holding the Speed button for 3 seconds.


What are the steps to replace the filter in the GUARDIAN TECHNOLOGIES GERMGUARDIAN AC5350 air purifier?

1. Turn off and unplug the unit.

2. Press the lock and release button and remove the rear cover from the unit.

3. Remove the used Combination Filter (Filter C) and dispose of it in the garbage.

4. Insert filter system into the unit. Consult the arrow on the filter for correct installation direction.

5. Reattach the rear cover of the unit and securely latch into place.


How should I check and maintain the filter on the GUARDIAN TECHNOLOGIES GERMGUARDIAN AC5350 air purifier?

Maintain the filter by checking it frequently. Depending on air quality conditions, you may need to replace it more frequently.

Vacuum the carbon filter layer as needed to remove loose debris and dust and to help prolong the life of your filter.

To check the status of the filter, peel back the carbon layer to expose the pleated filter. If the filter is no longer white and is covered in grey dust/dirt it should be replaced.

Do NOT try to wash and re-use the Combination Filter.


What is the procedure for installing and removing the UV-C Bulb on the GUARDIAN TECHNOLOGIES GERMGUARDIAN AC5350 air purifier?

1. Turn off and unplug unit. Press the lock and release button and remove the rear cover from the unit.

2. Remove the combination filter.

3. Use a Philips head screwdriver to remove 2 screws and detach the UV-C Metal Shield.

4. The UV-C Bulb is removed by carefully grasping the bulb with a clean cloth or tissue and pulling the bulb straight out of the unit. The bulb is NOT visible until the UV-C METAL SHIELD has been removed.

5. The UV-C Bulb is reinstalled by sliding it, horizontally, back into the slots at the top of the unit.


What should I do if the GUARDIAN TECHNOLOGIES GERMGUARDIAN AC5350 air purifier unit does not operate?

Check that the unit is plugged in.

Check that filter is in place.

Confirm that filter is Genuine Replacement Filter.

Call Customer Service.


What should I do if the GUARDIAN TECHNOLOGIES GERMGUARDIAN AC5350 air purifier unit shuts off unexpectedly?

Check that unit is plugged into a working electrical outlet.

Check that filter is firmly in place.

Check that the Rear Cover is latched firmly in place.

Call Customer Service.


What should I do if there is no air circulating from the GUARDIAN TECHNOLOGIES GERMGUARDIAN AC5350 air purifier unit?

Unplug unit. Check Pre-/Carbon and filters.

Clean Pre-/Carbon Filter if necessary.

Replace filter if necessary.


What should I do if there is an increase in noise level from the GUARDIAN TECHNOLOGIES GERMGUARDIAN AC5350 air purifier?

Make sure the filters are clean. Replace if necessary.


How can I shut off the beeping sound when control buttons are pushed on the GUARDIAN TECHNOLOGIES GERMGUARDIAN AC5350 air purifier?

To shut off the “beeping” sound when buttons are pushed:

1. Press and hold the TIMER and UV buttons for 3 seconds.

2. Select ON/OFF.

‘Beeping’ will automatically be reset to ON when the unit is unplugged.


What should I do if the red light is flashing on the GUARDIAN TECHNOLOGIES GERMGUARDIAN AC5350 air purifier?

Replace filter and reset system.


What should I do if the blue ring on the GUARDIAN TECHNOLOGIES GERMGUARDIAN AC5350 air purifier is flashing?

Replace bulb and reset system.