EDGESTAR AP10000HW (01) Image

FREE ENGLISH EDGESTAR AP10000HW (01) PDF USER GUIDE
FREE ENGLISH EDGESTAR AP10000HW (01) PDF USER MANUAL
FREE ENGLISH EDGESTAR AP10000HW (01) PDF OWNER GUIDE
FREE ENGLISH EDGESTAR AP10000HW (01) PDF OWNER MANUAL
FREE ENGLISH EDGESTAR AP10000HW (01) PDF REFERENCE GUIDE
FREE ENGLISH EDGESTAR AP10000HW (01) PDF INSTRUCTION GUIDE
FREE ENGLISH EDGESTAR AP10000HW (01) PDF REFERENCE MANUAL
FREE ENGLISH EDGESTAR AP10000HW (01) PDF INSTRUCTION MANUAL
FREE ENGLISH EDGESTAR AP10000HW (01) PDF OPERATING INSTRUCTIONS


CLICK HERE TO DOWNLOAD EDGESTAR AP10000HW (01) PDF MANUAL

If this is not the document you want for this product, click here to see if we have any other documents for this product.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

What are the general safety instructions for using the portable air conditioner?

This portable air conditioner is not intended to be used by children. Children should be supervised to ensure that they do not play with this product.

Do not allow children to play with the controls or drop any objects into the air outlets or vents.

Do not place objects or let any person sit on top of the unit.

Only use in the upright position on a flat, level surface and provide at least 20 inches of clearance from any walls or objects.

Route the power cord carefully to avoid a tripping hazard.

This unit is intended for domestic use only. Do not use the portable air conditioner for industrial or commercial use. Any other use may invalidate the warranty.


What are the electrical safety instructions for using the portable air conditioner?

This unit is designed for indoor use only.

Do not use the unit in extremely humid or wet environments.

Do not wet the housing or control panel.

Do not pull the unit by the cord.

Always turn the unit off and unplug it from the socket when cleaning.

Unplug the unit if it is not going to be used for a long period of time.

Do not operate the unit with a damaged plug or a loose socket.

Use only the correct power supply with appropriate amperage.

If the power cord is damaged, it must be replaced by the manufacturer, a service agent, or qualified technician.

Do not remove any part of the casing unless instructed by an authorized technician.


How do I ensure the Leakage-Current Detection and Interruption (LCDI) safety plug is working properly?

Plug the power cord to a grounded outlet.

Press the TEST button on the LCDI plug. This should cut the power to the air conditioner.

Press the RESET button to start using your air conditioner.

If the indicator light remains lit after pressing the TEST button, please contact EdgeStar support.

DO NOT USE YOUR PORTABLE AIR CONDITIONER IF THE TEST FAILS.

Do not use the TEST and RESET buttons as an ON/OFF switch.


How do I install the activated carbon filter?

Remove the pre-filter frame from the unit.

Remove the activated carbon filter from its plastic bag.

Place the activated carbon filter on the back of the unit.

Install the pre-filter frame to the unit.


How often should the activated carbon filter be replaced?

Replace the activated carbon filter every 2-3 months or as needed.


How do I install the window kit and exhaust hose?

Open the window and insert the window kit to cover the open gap. Next, slide the window across so that the kit is held securely. You may need to adjust the size of the window kit and secure it with screws. This technique may also be used for sash windows.

Thread the exhaust hose to the air outlet of the portable air conditioner.

Thread the oval adapter to the exhaust hose.

Attach the oval adapter to the window kit.


What care should be taken when securing the window after installing the window kit?

Take care to secure your window against intruders.


How should the exhaust hose be used and positioned?

Use the hose provided and attach the exhaust hose to the back of the air conditioner.

Avoid kinks and bends in the exhaust hose as this will cause the unit to work less efficiently. Improper setup may cause the unit to overheat and shut off.


What is the recommended length for the exhaust hose?

The hose may be extended from 11″ to 59.” For maximum efficiency use the shortest length possible. Longer hoses are not recommended.


How do I turn the unit on or off?

To turn the unit on, press the Power button and the unit will start in auto mode. If the ambient temperature is:

Higher than 74° F, the unit will operate in cooling mode.

Higher than 68° F but below or equal to 74° F, the unit will operate in fan mode.

Below 68° F, the unit will operate in heating mode.

An indicator light will display next to the corresponding mode.

The display window shows the ambient room temperature from 32°F to 122° F.

To turn the unit off, press the Power button again.


How do I select between Automatic, Cooling, Heating, or Fan Mode?

Press the MODE button to select the desired mode: automatic, cooling, heating or fan. The indicator of your selected mode comes on.


How do I set the temperature?

Press the ‘Up’ or ‘Down’ buttons to set the temperature you desire.

The display window will show the temperature you set as you press the ‘Up’ or ‘Down’ buttons. Otherwise, it will always show the ambient temperature.

The default temperature of this machine is: 75° F for cooling.

Temperature control only works in cooling and heating modes.


How do I set the fan speed?

Press the ‘Speed’ button to choose between high or low. The high or low indicator will light on.

If the unit is in ‘Auto’ mode, it will choose the fan speed automatically according to the ambient temperature (the related indicators will light up). While in ‘Auto’ mode pressing the ‘Speed’ button will have no effect.


How do I set the timer to automatically shut off the unit?

While the machine is running, press the ‘Timer’ button to set the number of hours you want to wait for the machine to shut off automatically. You are able to set the time between 1 to 12 hours by continuing to press the ‘Timer’ button. The timer indicator will light on. When the time set has elapsed, the machine will turn off automatically. The display window will show the hour(s) you set as you press the ‘Timer’ button. If the timer is not engaged, the unit will work continuously.


How do I set the timer to automatically power-on the unit?

While the machine is turned off, you can set the machine to power on by pressing the ‘Timer’ button, and setting the desired time. For example, if you set the timer to ‘2’, the unit will automatically turn on after 2 hours.


How does the heating function work?

When using Heat Pump, the ambient warm air is recycled and used to heat the area where it is required. The Exhaust Pipe must be fitted firmly to allow the cold air to be removed outside.

Continuous drain is compulsory while the unit is in heat mode. Working range for heating function is 41 to 81°F. For temperature outside this range, the unit may not work properly.


How do I use the remote control?

All the control panel functions can also be set with the remote control.

LED Indicator – Lights up when you press any of the buttons.

Power Button – Used to power the unit on or off.

Mode Button – Used to change between auto, cooling, heating, or fan modes.

Timer Button – Used to set the timer function.

Up Button – Used to increase the temperature.

Down Button – Used to decrease the temperature.

Fan Speed Button – Used to set the fan speed.

The remote uses two AAA batteries.


How do I regulate the air flow direction?

Move the roller on the air vent to the left or right to control the air flow direction.


What is important to know about the compressor’s life?

To prolong the compressor’s life, please wait at least 3 minutes before turning the unit back on after shutting it off.


When does the cooling system shut off and restart?

The cooling system will shut off if the ambient temperature is lower than the set one. The fan, however, keeps working on the set level. If the ambient temperature rises above the selected level, the cooling system will return to operation.


When does the heating system switch off and return to work?

On the contrary, the heating will switch off if the ambient temperature is higher than the set one (still, the ventilation keeps working on the set level). As the ambient temperature drops below the selected level, the heating will return to work.


What is the ANTI-FROST function?

This machine is equipped with ANTI-FROST function. While using the heating function during low temperature, sometimes the heating will stop for a while in order to melt the frost. As this occurs, just wait for the heating to return to work.


How do I manually drain water from the portable air conditioner?

Turn off the air conditioner (avoid moving it when full).

Position a container (a water tray, for example) underneath the drain hole.

Remove the drain cap & rubber plug from the drain hole and allow the water to drain out.

When the container is almost full, replace the rubber plug in the drain hole and empty the water tray.

Repeat until the unit is emptied.

Replace the rubber plug and tighten the drain cap firmly.

Switch on the unit – the Water Full indicator will stop flashing.


How do I operate the unit without needing to manually empty the water tank?

Remove the drain cap and rubber plug and retain for future use.

Connect the drain tube supplied to the water outlet as shown and locate the other end into a drain.


How can the drain tube be extended?

The drain tube may be extended by adding an extension tube and using a suitable connector. If you want to extend the water tube, you can connect it with another tube (Diameter: 0.71″).


What are the important notes when extending the drain tube for continuous drainage?

The drain must be at or below the outlet level.

Flashing Comp / Water indicator will not function in this mode of drainage.

This unit will not shut off when an external drain pan/tray is filled.

When the room humidity is over 85%, continuous drainage is recommended.


How do I clean the portable air conditioner unit?

Always unplug the air conditioner from the power outlet before cleaning. Clean the air conditioner regularly to maximize performance and efficiency.

Use a soft damp cloth to wipe the body clean.

Use a soft bristle brush to clean between the control panel’s buttons.

Never use abrasive chemicals, gasoline, detergents, chemically treated cloths, or other cleaning solvents that may damage the cabinet exterior.


How do I clean the pre-filter?

Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt, then rinse thoroughly under warm running water that is not hotter than 104° F. Dry thoroughly before replacing.

The activated carbon filter is not washable- replace it as needed.


What warning should be observed regarding filters?

Never operate the unit without the filters.


How do I prepare the portable air conditioner for storage?

Drain all the water from the unit before storing. Operate the unit in fan mode for a few hours to thoroughly dry the inside.

Clean or change the filter.

Unplug and store the power cord as shown.

Replace the unit in the original carton, or cover it before storing away.


How can the performance and efficiency of the portable air conditioner be maximized?

Do not cover the air outlet (exhaust) while in use.

Do not place the unit in front of curtains or drapes- to ensure they do not obstruct the air intake.

Minimize the length of the exhaust hose.

Make sure the exhaust hose is as straight as possible.

Keep curtains, blinds or drapes closed during the sunniest part of the day.

Use the timer to operate the unit before it is needed. For example, set the timer to turn on the unit in cooling mode for 3 or more hours to cool the room before you arrive. You may want to operate the unit all day if you live in a warmer climate.

Minimize the heat sources (direct sunlight, computers, servers, people, etc.) in the room.

Close all windows and doors.

Use the unit in a contained room. For example, a room with four walls and a roof, instead of a partitioned studio, or warehouse.

Make sure the unit is on a level surface.

Minimize the amount of humidity in the room. For example, adding a dehumidifier.

To prolong the compressor’s life, please wait at least 3 minutes before turning the unit back on after shutting it off.

Inspect and keep the pre-filters clean by cleaning regularly.

Inspect and replace the activated carbon filters regularly.

Perform routine maintenance.


My air conditioner is not functioning at all. What should I do?

The air conditioner may not be receiving electrical power. Make sure the unit is plugged in.

Press the test/reset buttons on the LCDI power cord.

Move the air conditioner to another outlet that is able to provide sufficient power. Check your circuit breaker. (Refer to the rating label on the back of the unit to determine the Amperage draw).

Check to see if the Compressor/ Water indicators are flashing. Drain the unit and restart.

If you are using the remote to power on the unit, check to see if the remote’s batteries are installed correctly. If the indicator light on the remote does not turn on when pressing the power button, replace the batteries.

If no indicator lights turn on when you hit the power button, the control panel may be unplugged from the circuit board. Contact customer service.


My air conditioner is not cooling at all. What should I do?

Make sure that the unit is set on cooling mode. Set temperature manually.

Note: the compressor may take up to 3 minutes to turn on.

The unit should be in a room where the ambient temperature is below 95 degrees F. If the ambient temperature is above 95 degrees F, the unit will not blow cold air. Follow the steps below to increase the performance and efficiency of your unit’s compressor:

Minimize the heat sources in the room.

Minimize the size of the area to be cooled. (Close doors and windows.).

Close curtains or pull down blinds, and minimize the direct sunlight into the room.

Remove additional heat sources such as computer equipment, servers, etc.

Run the unit before it is needed. For example, run the unit in the morning before the area gets hot, and continue to run the unit all day long in order to maintain a low temperature.

Use more than one unit to cool the area, or use a larger unit.

Remove the exhaust hose and run the unit for 5 minutes. Compare the air temperature between the exhaust and the front. If the exhaust is warmer than the interior air, follow the steps above to decrease the ambient temperature of the room.

The filter may be dusty or blocked. Clean the filter. Replace it if needed.

Check to make sure the air intake or exhaust ports are not partially obstructed.

Check to see if the condenser coils located behind the air filters are dirty. Carefully vacuum the coils clean.


My air conditioner is making a loud noise. What should I do?

Make sure the unit is on a level surface.

Make sure that a foreign object has not jammed the fan.

Make sure that the floor underneath the machine is even.

If the unit is level and making a continuous knocking noise, contact customer service.


The unit runs for a little while and then it trips the power cord or the circuit breaker, or the control panel lights blink randomly. What should I do?

Move the unit to another outlet or unplug the unit, wait for a couple of minutes, and plug it in.

The air conditioner may be plugged into an outlet that cannot supply the correct amount of current. Plug the unit in a different room and test. If this works, contact an electrician about the outlet that is not supplying enough current.

The unit may have a faulty control panel. Contact customer service.


My air conditioner is leaking. What should I do?

Make sure that the rubber plug and drain cap are attached, and the unit is on a level surface.

Check for cracks or damage to the bottom of the unit.


What are the specifications of the EdgeStar Portable Air Conditioner AP10000HW?

Product Description: EdgeStar Portable Air Conditioner

Model: AP10000HW

Voltage / Frequency: 115 V, 60 Hz

Power / Ampere Consumption for cooling: 830W / 7.9 A

Power / Ampere Consumption for heating: 920W / 8.2 A

Maximum Dehumidifying Capacity: 50 pints/day

Refrigerant: R22 / 15.2 OZ

Fan speeds: 2 (High and Low)

Timer: 1-12 hours

Net Weight: 51 lbs.

Dimensions (WxDxH): 12 3/8″ x 14 1/16″ x 27 15/16”


CLICK HERE TO DOWNLOAD EDGESTAR AP10000HW (01) PDF MANUAL


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.