What are the system requirements for connecting to the BOSCH DINION 5100I IR NBE-5704-AL-GOV via a web browser?

To operate your BOSCH DINION 5100I IR NBE-5704-AL-GOV camera, the following system requirements are recommended:

Computer: A computer with a Dual core HyperThreading processor or better.

Graphics Card: A graphic card with performance that matches or is better than the resolution of the camera.

Operating System: Windows 10 or later.

Network: Network access is required.

Web Browser: Google Chrome, Microsoft Edge, or Mozilla Firefox.

Application Software: Alternatively, you can use software such as Video Security Client, Bosch Video Client, or BVMS.


How do I establish a connection to my BOSCH DINION 5100I IR NBE-5704-AL-GOV camera?

To connect to your BOSCH DINION 5100I IR NBE-5704-AL-GOV, your device must have a valid IP address. By default, DHCP is pre-set, so a DHCP server will assign an IP address. If no DHCP server is available, a link-local address (auto-IP) in the range of 169.254.1.0 to 169.254.254.255 will be assigned.

You can use the Project Assistant app or Configuration Manager to find the IP address.

Step 1. Start your web browser.

Step 2. Enter the IP address of the device as the URL in the browser’s address bar.

Step 3. During the initial installation, confirm any security questions that appear.

If you cannot connect, the unit may have reached its maximum number of connections, which can be up to 50 web browser connections or up to 100 connections via Bosch Video Client or BVMS.


What are the password requirements for the BOSCH DINION 5100I IR NBE-5704-AL-GOV?

The BOSCH DINION 5100I IR NBE-5704-AL-GOV requires a strong password that meets the following conditions:

• 8 to 19 characters in length

• Must contain both upper and lower case letters

• Must contain a minimum of 1 digit

• Must contain a minimum of 1 special character

• The following special characters are not allowed: ‘@’, ‘&’, ‘<', '>‘, ‘:’, ‘+’


How do I set the initial password and log in to my BOSCH DINION 5100I IR NBE-5704-AL-GOV?

The first time you access your BOSCH DINION 5100I IR NBE-5704-AL-GOV, you will be prompted to set a service-level password.

Setting the Initial Password:

When you launch the device webpage directly, an initial password page will appear with input fields and a password strength gauge. Enter the user name (“service”) and a password that meets the security requirements in the appropriate fields.

Logging In:

After the service-level password is set, the device will display a dialog box for logging in each time you access it.

Step 1. Fill in the fields for User name (“service”) and Password.

Step 2. Click OK. If the password is correct, the desired page will appear.


What do the icons in the application bar of the BOSCH DINION 5100I IR NBE-5704-AL-GOV web interface do?

The application bar provides access to the main functions of your BOSCH DINION 5100I IR NBE-5704-AL-GOV camera:

Icon Name Function
Live Live Click this icon to view the live video stream.
Playback Playback Click this icon to play back recorded sequences. This link is only visible if a storage medium has been configured.
Configuration Configuration Click this icon to configure the device.
Dashboard Dashboard Click this icon to see detailed system information.
Links Links Click this icon to navigate to the Bosch download store.
Logout Logout Click this icon to log out of the device.
? Help Click this icon to get context-sensitive help for the page you are browsing.

How do I make and save configuration changes on my BOSCH DINION 5100I IR NBE-5704-AL-GOV?

On the Configuration page, you can change settings by entering new values or selecting from a list.

• If a page does not have a Set button, changes are applied immediately.

• If a page has a Set button, you must click it for a change to take effect. Clicking the Set button saves the settings only for the current field; changes in other fields on the same page are ignored.

• If a change requires a reboot, the Set button will change to Set and Reboot. Make your desired changes and then click Set and Reboot. The camera will restart and the new settings will be activated.


How do I operate the Live page on my BOSCH DINION 5100I IR NBE-5704-AL-GOV?

The Live page allows you to view and interact with the live video stream from your BOSCH DINION 5100I IR NBE-5704-AL-GOV.

Video Stream Selection:

Step 1. On the left side of the browser, expand the Connection group.

Step 2. Click the Stream drop-down arrow and select the stream you wish to view.

Digital I/O:

The alarm symbol indicates the status of an alarm input; it lights up when the input alarm is active. To activate an alarm output, click the checkmark symbol; the symbol will light up when the output is activated.

Recording Status:

The hard drive icon below the image displays a moving graphic to indicate a running recording. A static icon is displayed when no recording is taking place.

Full-Screen Display:

Click the full-screen icon to view the stream in full-screen mode. Press the Esc key to return to the normal view.

Show Latest Event:

Click the “Show latest event” icon to open the Playback page and watch the last recorded important event.

Storage, CPU and Network Status:

In the upper right of the window, you can view status icons. Hover over them to see the local storage activity percentage, CPU load, and network load.


What do the status icon overlays on the video image of the BOSCH DINION 5100I IR NBE-5704-AL-GOV mean?

Various overlays on the video image of your BOSCH DINION 5100I IR NBE-5704-AL-GOV provide important status information:

Decoding error: The frame might show artifacts due to decoding errors.

Alarm flag: Indicates that an alarm has occurred.

Communication error: Indicates a communication error, such as a connection failure to the storage medium.

Gap: Indicates a gap in the recorded video.

Watermark valid: The watermark on the media item is valid.

Watermark invalid: Indicates that the watermark is not valid.

Motion alarm: Indicates that a motion alarm has occurred.

Storage discovery: Indicates that recorded video is being retrieved.


How do I search for and export recorded video from my BOSCH DINION 5100I IR NBE-5704-AL-GOV?

You can search, play back, and export recordings from the Playback page of your BOSCH DINION 5100I IR NBE-5704-AL-GOV. This feature is available only when a direct iSCSI or memory card is configured for recording.

Searching for Recorded Video:

Step 1. Expand the Search group on the left side of the browser.

Step 2. To limit the search, enter the date and times for the start and stop points.

Step 3. Select a search parameter from the drop-down box.

Step 4. Click Search. The results are listed in a new window. Click a result to play it back.

Exporting Recorded Video:

Step 1. On the left side of the browser, expand the Export group.

Step 2. Select a track from the track list or search results.

Step 3. The start and stop date and time will be filled in automatically. Change them if necessary.

Step 4. In the Time lapse drop-down box, select Original or Condensed.

Step 5. In the Location drop-down box, select a target.

Step 6. Click Export to save the video track.


How do I control playback on the BOSCH DINION 5100I IR NBE-5704-AL-GOV?

Playback on your BOSCH DINION 5100I IR NBE-5704-AL-GOV is controlled using the time bar and buttons below the video image.

Using the Time Bar:

• Click anywhere in the time bar to jump to that point in time.

• Use the plus or minus icons or the mouse scroll wheel to change the time interval displayed.

• Click the alarm jump buttons to go to the next or previous alarm event. Red bars indicate when alarms were triggered.

Using the Control Buttons:

Start/Pause playback: Play or pause the video.

Speed regulator: Select the playback speed, either forward or backward.

Step frame-by-frame: Use the small arrows to step forward or backward one frame at a time when paused.


How do I create a new user on my BOSCH DINION 5100I IR NBE-5704-AL-GOV?

To create a new user for your BOSCH DINION 5100I IR NBE-5704-AL-GOV, navigate to the User Management page (Configuration > General > User Management).

Step 1. In the section below Authentication modes, click Add.

Step 2. In the box that appears, fill in the following fields:

User name: Enter a name with a minimum of 5 and a maximum of 31 characters.

Group: Select the appropriate authorization level (live, user, IVA configuration, or service).

Type: Select either Password (and enter it twice) or Certificate.

Step 3. Click Set to confirm and create the new user.

To edit an existing user’s password, click the pencil icon in the Type column for that user.


How do I set the date and time on my BOSCH DINION 5100I IR NBE-5704-AL-GOV?

To configure the date and time settings on your BOSCH DINION 5100I IR NBE-5704-AL-GOV, navigate to the Date/Time page (Configuration > General > Date/Time). Make sure that recording is stopped before syncing time to a PC.

Step 1. Select the required date format from the dropdown menu.

Step 2. Enter the current date manually.

Step 3. Enter the current time manually, or click the Sync to PC button to copy your computer’s system time to the camera.

Step 4. Select the time zone in which the system is located.


How do I configure Daylight Saving Time (DST) on my BOSCH DINION 5100I IR NBE-5704-AL-GOV?

The internal clock of your BOSCH DINION 5100I IR NBE-5704-AL-GOV can switch automatically for DST. If the date, time, and time zone are set correctly, a DST table is created automatically. To edit this table:

Step 1. First, check the time zone setting. If it is not correct, select the appropriate time zone and click Set.

Step 2. Click Details to edit the DST table.

Step 3. Click Generate to fill the table with preset values from the unit.

Step 4. Click an entry in the table to highlight it for changes.

Step 5. Click Delete to remove a highlighted entry.

Step 6. Use the list boxes under the table to change a selected entry or add new data to empty lines.

Step 7. When finished, click OK to save and activate the table.


How do I configure a time server for my BOSCH DINION 5100I IR NBE-5704-AL-GOV?

Your BOSCH DINION 5100I IR NBE-5704-AL-GOV camera can receive a time signal from a time server to set its internal clock.

Step 1. In the Time server address field, enter the IP address of a time server.

Step 2. To have a DHCP server provide the time server address, select the Overwrite by DHCP option.

Step 3. In the Time server type dropdown, select the protocol supported by the time server (Time protocol, SNTP protocol, TLS protocol, or Off to disable).

Step 4. Click Set to apply the changes.


How do I use the Lens Wizard to configure the lens on my BOSCH DINION 5100I IR NBE-5704-AL-GOV?

The Lens Wizard, found in the Installer Menu (Configuration > Camera > Installer Menu), is used to configure the field of view and focus of your BOSCH DINION 5100I IR NBE-5704-AL-GOV lens.

Live Video Window: Click in the live video window to move the camera and center its field of view at the selected position.

Set lens to default position: Select Default to set the lens to its default position.

Optical zoom: Use the slider to adjust the optical zoom.

Autofocus: Select either Local Range (preferred) or Full Range to automatically focus the image.

Focus position: Use the slider to manually adjust the focus position. This automatically adjusts to the autofocus setting.

IR-corrected lens: Click the checkbox to activate or deactivate the IR correction function. In dark environments where IR illuminators are the main light source, this mode should be enabled. In daylight, it is not required.


How do I restore settings or factory defaults on my BOSCH DINION 5100I IR NBE-5704-AL-GOV?

You can restore settings from the Installer Menu (Configuration > Camera > Installer Menu) on your BOSCH DINION 5100I IR NBE-5704-AL-GOV.

Restore settings: Click Restore to restore all settings, except network settings, to their defaults. This action also clears the service-level password, requiring you to reset it before proceeding.

Factory defaults: Click Defaults to restore all settings, including passwords and network settings, to their original factory defaults. This action also clears the service-level password.


What are the White Balance options for the BOSCH DINION 5100I IR NBE-5704-AL-GOV?

The following table identifies the options available in the White balance field and the additional fields that appear depending on the option selected on your BOSCH DINION 5100I IR NBE-5704-AL-GOV.

Option in field “White balance” Additional fields for configuration NOTES
Basic auto The three fields R-gain, G-gain, and B-gain only appear when the hold button is pushed.
Standard auto
Sodium lamp auto
Manual RGB R-gain
G-gain
B-gain

What are the different encoder stream profiles available on the BOSCH DINION 5100I IR NBE-5704-AL-GOV?

The BOSCH DINION 5100I IR NBE-5704-AL-GOV offers several encoder profiles to prioritize image quality or bit rate for different scenarios.

Profile number Description
Profile 1 For a high resolution image, the video bit rate and frame quality are adjusted to ensure that the picture quality is the priority.
Profile 2 For a high resolution image, the video bit rate and frame quality are adjusted to a median profile for everyday use.
Profile 3 For a high resolution image, the video bit rate and frame quality are adjusted to ensure that the bit rate is the priority.
Profile 4 For a low resolution image, the video bit rate and frame quality are adjusted to ensure that the picture quality is the priority.
Profile 5 For a low resolution image, the video bit rate and frame quality are adjusted to a median profile for everyday use.
Profile 6 For a low resolution image, the video bit rate and frame quality are adjusted to ensure that the bit rate is the priority.
Profile 7 Ideal for encoding on a DSL uplink where bit rate limitations are critical.
Profile 8 Ideal for encoding on a 3G uplink where bit rate limitations are critical.

How can I obtain the highest image quality at the lowest bandwidth on my BOSCH DINION 5100I IR NBE-5704-AL-GOV?

To optimize image quality and bandwidth on your BOSCH DINION 5100I IR NBE-5704-AL-GOV, even with increased movement in the picture, configure the quality settings as follows:

Step 1. Observe the coverage area during normal movement in the preview images.

Step 2. Set the value for Min. P-frame QP to the highest value at which the image quality still meets your needs. (A lower QP value means higher quality and higher data load).

Step 3. Set the value for I/P-frame delta QP to the lowest possible value. This saves bandwidth in normal scenes, and the quality is retained during increased movement because the bandwidth usage will increase up to the value set under Maximum bit rate.


How do I configure and delete Privacy Masks on my BOSCH DINION 5100I IR NBE-5704-AL-GOV?

You can block specific areas of a scene from view using Privacy Masks on your BOSCH DINION 5100I IR NBE-5704-AL-GOV. A total of eight masks can be active at the same time.

To configure a Privacy Mask:

Step 1. Go to Configuration > Camera > Privacy Masks.

Step 2. Select the mask number from the drop-down list.

Step 3. Click the plus button.

Step 4. Adjust the mask in the image: Double-click on the edges to add or remove nodes, and click and drag the nodes to position them correctly.

Step 5. Check the Enabled check box to activate the mask.

Step 6. Click the Set button to apply the related changes.

To delete a Privacy Mask:

Step 1. Select the mask number from the drop-down list.

Step 2. Click the trashcan icon.

Step 3. Click the Set button to apply the changes.


How do I use the Pixel Counter feature on my BOSCH DINION 5100I IR NBE-5704-AL-GOV?

The Pixel Counter on your BOSCH DINION 5100I IR NBE-5704-AL-GOV helps you check if the resolution in a specific area meets the requirements for functions like identification. It displays the number of horizontal and vertical pixels in a highlighted area.

Step 1. Click Freeze to freeze the camera image if the object you want to measure is moving.

Step 2. To reposition a zone, place the cursor over it, hold down the mouse button, and drag it into position.

Step 3. To change the shape of a zone, place the cursor over the edge of the zone, hold down the mouse button, and drag the edge to the required position.


How do I manage storage media (iSCSI, SD card) on my BOSCH DINION 5100I IR NBE-5704-AL-GOV?

You can manage storage media from the Configuration > Recording > Storage Management page of your BOSCH DINION 5100I IR NBE-5704-AL-GOV.

Activating Storage Media:

Step 1. In the Storage overview section, double-click a storage medium (e.g., an iSCSI LUN or SD card) to add it to the Managed storage media list.

Step 2. Click Set to activate all media in the list. The Status column will show “Online”.

Step 3. Check the box in the Rec. 1 or Rec. 2 column to assign recording tracks to the target.

Deactivating Storage Media:

Step 1. Click a storage medium in the Managed storage media list to select it.

Step 2. Click Remove below the list.

Formatting or Wiping Storage Media:

Step 1. Click a storage medium in the Managed storage media list to select it.

Step 2. Click Edit below the list.

Step 3. In the new window, click Format to delete all recordings and recreate the file structure, or click Wipe to delete all data without recreating the file structure.

Step 4. Click OK or Close to exit the window.

Step 5. Click Set to apply the changes.


How do I set up a recording schedule on my BOSCH DINION 5100I IR NBE-5704-AL-GOV?

The Recording Scheduler on your BOSCH DINION 5100I IR NBE-5704-AL-GOV (Configuration > Recording > Recording Scheduler) allows you to link recording profiles to specific days and times.

For Weekdays:

Step 1. Click the profile you want to assign in the Time periods box.

Step 2. In the schedule table, click a field and, while holding down the left mouse button, drag the cursor across all the fields you want to assign to that profile.

Step 3. To deselect intervals, click the No recordings profile and drag across the fields.

Step 4. You can also use Select All and Clear All to manage the intervals.

Step 5. When finished, click Set to save the settings.

For Holidays:

Step 1. Click the Holidays tab.

Step 2. Click Add.

Step 3. Select the desired From and To dates from the calendar.

Step 4. Click OK.

Step 5. Assign a recording profile to the defined holiday period as described for weekdays.

Step 6. Click Set to apply the changes.


How do I set up alarm emails on my BOSCH DINION 5100I IR NBE-5704-AL-GOV?

To configure your BOSCH DINION 5100I IR NBE-5704-AL-GOV to send emails upon an alarm, go to Configuration > Alarm > Alarm email.

Step 1. Select On for the Send alarm e-mail option.

Step 2. Enter the Mail server IP address.

Step 3. Select the appropriate SMTP port.

Step 4. Enter the SMTP user name and SMTP password for the mail server.

Step 5. Select the Format (Standard with JPEG or SMS).

Step 6. Select the Image size for the attachment.

Step 7. Check Attach JPEG from camera to include an image.

Step 8. Enter the recipient’s email in Destination address.

Step 9. Enter a name for the camera in Sender address to identify the email’s origin.

Step 10. Click Send Now to test the email function.

Step 11. Click Set to apply the changes.


How do I update the firmware on my BOSCH DINION 5100I IR NBE-5704-AL-GOV?

You can update the firmware on your BOSCH DINION 5100I IR NBE-5704-AL-GOV via the web interface at Configuration > Service > Maintenance. Before starting, ensure you have the correct firmware file and do not interrupt the process.

Using an Update Server:

Step 1. The address of the update server is displayed. Click Check to connect.

Step 2. Select the appropriate firmware version for your camera to download it from the server.

Using a Firmware File:

Step 1. First, store the firmware file on your hard disk.

Step 2. In the Firmware section, enter the full path for the firmware file or click Browse… to locate and select it.

Step 3. Click Upload to begin transferring the file. The progress bar will monitor the transfer.

The new firmware will be unpacked and the camera’s memory will be reprogrammed. The device will reboot automatically upon successful completion.


How do I save or load a configuration file on my BOSCH DINION 5100I IR NBE-5704-AL-GOV?

You can manage configuration files for your BOSCH DINION 5100I IR NBE-5704-AL-GOV at Configuration > Service > Maintenance.

To load a configuration file to the camera:

Step 1. Click Browse…. A dialog box will appear.

Step 2. Locate and open the desired configuration file. Ensure it is from the same device type.

Step 3. If the file is password-protected, enter the password.

Step 4. Click Upload. The camera will reboot automatically after the upload is complete.

To save the camera’s settings to a file:

Step 1. Click Download. A dialog box will appear.

Step 2. Enter a password to protect the configuration file.

Step 3. Enter a file name if required and save the file to your computer.


How do I manage certificates on my BOSCH DINION 5100I IR NBE-5704-AL-GOV?

You can manage security certificates on your BOSCH DINION 5100I IR NBE-5704-AL-GOV from the Certificates page (Configuration > Service > Certificates).

To add a certificate:

Step 1. Click Add.

Step 2. In the “Add certificate” window, you can:

Upload certificate: Click Browse… to navigate to a certificate file, then click Upload.

Generate signing request: Fill in the necessary fields and click Generate to create a request for a signing authority.

Generate certificate: Fill in the necessary fields and click Generate to create a new self-assigned certificate.

To delete a certificate:

Step 1. Click the trashcan icon to the right of the certificate you wish to delete.

Step 2. In the “Delete file” window, click OK to confirm the deletion.

Note: You can only delete certificates that you have added; you cannot delete the default certificate.


When should I perform a hardware reset on my BOSCH DINION 5100I IR NBE-5704-AL-GOV?

You may need to complete a hardware reset on your BOSCH DINION 5100I IR NBE-5704-AL-GOV if you experience the following issues:

• You can power up the camera but cannot log on using the web browser.

• The camera does not start up, or fails to power up via PoE.

• The camera cannot search an IP address.

• The camera’s firmware has crashed.

• You forgot the password to access the camera.

• The image becomes frozen.

• You cannot update the firmware.

• The camera disconnects from the network at random and needs a reboot.

• The camera no longer finds pre-positions (preset positions).

• You cannot configure the camera using the web browser.

• The camera has no video out.

A factory default deletes all camera settings, including passwords, network settings, and image settings. This should only be done if you have no other option to restore operation.


How do I perform a physical hardware reset on my BOSCH DINION 5100I IR NBE-5704-AL-GOV?

To perform a hardware reset on your BOSCH DINION 5100I IR NBE-5704-AL-GOV, follow these steps:

Step 1. Apply power to the camera.

Step 2. Locate the hardware reset button. It is located underneath the device, protected by a panel cover, near the USB-C port and microSD card slot.

Step 3. Push and hold the reset button for more than 10 seconds. The red LED indicator on the device will begin flashing to show that the hardware reset has started.

Step 4. Let the camera complete a self-check. When the self-check is complete, the red LED will turn off.

Step 5. Search again for the IP address. Access the camera using the web browser and set the initial password for the camera.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

CLICK HERE TO DOWNLOAD BOSCH DINION 5100I IR NBE-5704-AL-GOV (01) PDF DOCUMENT


Leave comments, questions, reviews, tips, tricks, hacks or page errors below. Account not required.