How do I enter the Factory Test Procedure on my ALLIANCE AWN43RSN305LW01?
Follow these steps to enter the mode:
1. Disconnect electrical power from the unit.
2. Reconnect electrical power to the unit.
3. Wait about 10 seconds.
4. Turn the Cycle Selection knob to the opposite of Normal Eco and stay on that selection for at least one second.
5. Press and hold the Start/Pause button.
6. Change the Cycle Selection knob to Normal Eco within 5 seconds.
7. Stay on Normal Eco for at least one second to enter the Factory Test Mode.
How do I test the mixing valve solenoids on my ALLIANCE AWN43RSN305LW01?
Test the mixing valve solenoids using an Ohm meter. Please note that resistance readings slightly out of the given ranges may be due to meter conditions and do not necessarily indicate mixing valve failure.
| Valve Type | Resistance Range |
|---|---|
| 120 Volt valves | 900 – 1100 Ohms |
| 240 Volt valves | 3200 – 4000 Ohms |
What should I do if the WASH and RINSE LEDs flash after installing a new control on my ALLIANCE AWN43RSN305LW01?
If these LEDs flash during the first fill, it may indicate that the pressure sensor harness was installed incorrectly. Follow these steps to correct the error:
1. Disconnect electrical power from the unit.
2. Remove the screws holding the hood assembly to the rear hood panel.
3. Tip the control panel down to locate the H7 connection block, which is a 4-pin block with white, red, and gray wires.
4. Press the connection block release arm and remove the block.
5. Relocate the connection block so the release arm is at the three o’clock position and matches the lock tab of the block on the control.
6. Re-install the control hood.
7. Reconnect electrical power to the unit.
8. Run the washer through a cycle to verify proper operation.
How do I level the ALLIANCE AWN43RSN305LW01?
1. Place a level on the cabinet top and check if the washer is level from side to side and front to back.
2. If not level, tilt the washer back to access the front leveling legs. Loosen the locknuts and adjust the legs by screwing them into or out of the washer base.
3. Once adjusted, tilt the washer forward on the front legs and lower it back down into position to set the rear self-leveling legs.
4. The washer must not rock. When level and not rocking, tighten the locknuts securely against the bottom of the washer base. Failure to tighten the locknuts may cause the washer to not remain stationary during operation.
What is the required drive bell torque for the ALLIANCE AWN43RSN305LW01?
When replacing or reinstalling the drive bell, torque the bolts to the following specifications:
| Location | Minimum | Maximum |
|---|---|---|
| Drive Bell to Washtub and Hub | 100 inch-pounds [11.3 Nm] | 140 inch-pounds [15.8 Nm] |
| Drive Bell to Top of Drive Shaft | 60 inch-pounds [6.78 Nm] | 100 inch-pounds [11.3 Nm] |
How can I clear a Pressure Sensor Error on my ALLIANCE AWN43RSN305LW01?
If the WASH and RINSE lights flash once, perform the following troubleshooting steps:
1. Check if the pressure sensor is connected to the front end control properly. If not, connect it.
2. Check if the pressure sensor harness is damaged. If it is damaged, replace the harness.
3. If the error is still displayed, replace the pressure sensor. If the problem persists, replace the front end control.
What should I check if my ALLIANCE AWN43RSN305LW01 has no hot water?
If the WASH and RINSE status lights flash 1 or 2 times, check the following:
1. Ensure the water supply faucet is open.
2. Check if the hoses are reversed. If they are, connect them to the proper faucets.
3. Check if the hot water fill hose is kinked. If so, straighten or replace the hose.
4. Check if the mixing valve screen or the screen in the outer end of the fill hose nearest the water supply faucet is clogged. If so, disconnect the hose and clean or replace the screen.
5. Check for proper voltage output from the output board to the mixing valve hot solenoid. If there is no voltage, replace the output board.
6. If the hot solenoid is inoperative, replace the valve.
7. Check if the pressure hose is clogged or damaged. If so, remove and clean or replace the hose.
8. If the temperature selector switch is not operating properly, use a wiring diagram to test the switch.
What should I check if my ALLIANCE AWN43RSN305LW01 has no cold water?
If the WASH and RINSE status lights flash 1 or 2 times, check the following:
1. Ensure the water supply faucet is open.
2. Check if the cold water fill hose is kinked. If so, straighten or replace the hose.
3. Check if the mixing valve screen or the screen in the outer end of the fill hose nearest the water supply faucet is clogged. If so, disconnect the hose and clean or replace the screen.
4. Check for proper voltage output from the output board to the mixing valve cold solenoid. If there is no voltage, replace the output board.
5. If the cold solenoid is inoperative, replace the valve.
6. Check if the pressure hose is clogged or damaged. If so, remove and clean or replace the hose.
7. If the temperature selector switch is not operating properly, use a wiring diagram to test the switch.
What should I check if the water fill does not stop at the proper level on my ALLIANCE AWN43RSN305LW01?
If you encounter a pressure sensor error, overflow error, or fill error, check the following:
1. If it is a pressure sensor error, check for a restricted or clogged pressure bulb or hose. If clear, replace the sensor.
2. If it is an overflow error, check for a leak in the mixing valve.
3. If there is an air leak in the pressure hose, replace the hose or pressure bulb.
4. If the mixing valve is inoperative, test the valve and replace if inoperative.
5. If siphoning is occurring because the drain hose is lower than the cabinet top, install a Siphon Break Kit.
6. Ensure the drain hose fits tight in the standpipe or drain. If not, provide an air gap around the drain hose and drain receptacle.
7. If there is water in the pressure hose, blow air through the hose to remove water or replace the hose.
8. Check for broken, loose, shorted, or incorrect wiring using the wiring diagram.