Free English ACURITE 00592W (01) PDF Document. Free English ACURITE 00592W (01) PDF User Guide. Free English ACURITE 00592W (01) PDF User Manual. Free English ACURITE 00592W (01) PDF Owner Guide. Free English ACURITE 00592W (01) PDF Owner Manual. Free English ACURITE 00592W (01) PDF Reference Guide. Free English ACURITE 00592W (01) PDF Instruction Guide. Free English ACURITE 00592W (01) PDF Reference Manual. Free English ACURITE 00592W (01) PDF Instruction Manual. Free English ACURITE 00592W (01) PDF Operating Instructions.


CLICK HERE TO DOWNLOAD ACURITE 00592W (01) PDF DOCUMENT

If this is not the document you want for this product, click here to see if we have any other documents for this product.

How to use the PDF below:
* Touchscreen: Swipe up/down with-in the PDF to scroll and pinch or spread with two fingers to zoom.
* Mouse: While your mouse is hovering over the PDF, use the mouse wheel to scroll and click on the – / + buttons at the bottom of the PDF to zoom.

NO IMAGE CONTENT AT THIS TIME. PLEASE CHECK BACK LATER

What is included in the package for the ACURITE 00592W weather station?

The package for the ACURITE 00592W includes the following items:

(1) Main Unit – dimensions: 9.25″ x 6″ x 1″

(1) Wireless Sensor – dimensions: 2.5″ x 3.5″ x 1″

(2) 1″ (2.5cm) screws with plastic anchors

(1) Instruction manual

*dimensions are approximate


How do I install batteries in the ACURITE 00592W main unit and wireless sensor?

Main Unit:

Always install batteries into the main unit first. On the back of the unit, remove the battery compartment cover. Insert 2 “AA” alkaline (or lithium) batteries. Replace the cover.

Wireless Sensor:

After batteries have been put into the main unit, remove the back cover of the wireless sensor by removing the 4 screws. Insert 2 “AA” alkaline (or lithium) batteries. Press the “TX” button and replace the back cover of the sensor.


What should I do when replacing the batteries for the wireless sensor on the ACURITE 00592W?

When replacing the batteries for the wireless sensor, remove the old batteries from the sensor and clear the sensor’s channel on the main unit by pressing and holding the CHANNEL button when the corresponding channel is displayed. Reinstall the new batteries into the wireless sensor and press and release the TX button to synchronize the units.


What type of batteries should I use for the ACURITE 00592W in cold temperatures?

Severe cold (below -4° F/-20° C) can cause alkaline batteries to freeze and function improperly. Use lithium batteries in extremely low temperature conditions to ensure continued operation.

Operating Range of Batteries:

LITHIUM BATTERIES: -22°F to 158°F (-30°C to 70°C)

ALKALINE BATTERIES: -4°F to 158°F (-20°C to 70°C)


How will I know when the batteries are low on the ACURITE 00592W?

When the battery level is low for the main unit or the wireless sensor, the low battery level icons will illuminate on the main unit’s display.


How should I place the main unit of the ACURITE 00592W?

You can choose either wall mount or table-top placement for the main unit.

• Choose a location for the unit that is at least 10 feet away from other electronic devices that may interfere with the wireless signal.

• For wall mounting, use the mounting slot on the back of the unit to hang it from one of the supplied screws.

• For table-top placement, attach the removable table stand by inserting the two prongs into the slots at the bottom of the main unit.


What are the placement recommendations for the ACURITE 00592W wireless sensor?

When placing the wireless sensor, consider these things:

• Although the sensor is designed for outdoor use, placement in a protected area will prolong its life.

• For mounting, use the mounting slot on the back of the unit to hang it from one of the supplied screws.

• The sensor must be within 100 feet (30 meters) of the main unit.

• The sensor is resistant to weather and to water. It is NOT WATERPROOF.

• Prolonged exposure to cold weather may cause damage to the LCD panel.

• The wireless sensor can be placed outdoors to observe outdoor temperatures and humidity.


How can I change the display on the wireless sensor for the ACURITE 00592W?

Press the “MODE” button located inside the back of the wireless sensor to display temperature and/or humidity in one of three ways:

1) Temperature continuously

2) Humidity continuously

3) Temperature for 5 seconds, then humidity for 5 seconds

Note: The sensor’s display setting does not affect the main unit’s display.


What do the buttons on the ACURITE 00592W main unit do?

BUTTON NAME PRESS & RELEASE PRESS & HOLD FOR 3 SECONDS
CH (CHANNEL) choose channel 1, 2, or 3 clears the current channel
MEMORY (min/max) read maximum & minimum values for temperatures, humidity (both indoor & outdoor) N/A
ALARM view alarm time for 5 seconds set alarm time
SET starts radio controlled time synchronization to set clock & calendar manually
+ turn alarm on/off OR raise a setting by one unit fast advance setting mode
– C/F zone select °C or °F OR lower a setting by one unit fast reverse in time setting mode & current time zone setting
SNOOZE / LIGHT silence the alarm for 5 minutes -or- activate backlight for low-light viewing N/A

What do the buttons on the ACURITE 00592W wireless sensor do?

BUTTON NAME PRESS & RELEASE
TX sends wireless signal to main unit
C/F select °C or °F display mode for wireless sensor
Mode choose display mode for wireless sensor
CH (1,2,or 3) choose channel 1, 2, or 3 (slide switch)

How do I manually set the time and date on the ACURITE 00592W?

1) Press and hold the “SET” button, and the year display will flash on the screen. Using the “+” and “-” buttons set the year. When the correct year is entered, press and release the “SET” button to confirm the setting.

2) Once you have confirmed the year, follow the same procedure to set the month, date, hour, minute, 12 or 24-hour time preference, and DST (Daylight Saving Time).

NOTE: You cannot change any settings manually if the clock is attempting to synchronize. Allow the clock to finish the cycle, and then manual changes can be made if the clock has not automatically acquired the signal and set itself to the correct time.


How do I set the time zone on my ACURITE 00592W?

The default setting is Pacific Time. If you live outside of the Pacific Time Zone, you will need to set your Time Zone using the following procedure:

1) Press and hold the “- / C/F” button on the front of the clock for three seconds. The area of the clock where the seconds are usually displayed will be replaced with the letter for the time zone it is currently set in.

2) If set to the default setting, you will see a flashing letter “P” on the screen after pressing and holding the “- / C/F” button. Press and release the “- / C/F” button until the letter shown corresponds to your time zone:

P = Pacific M = Mountain C = Central E = Eastern

Once your zone is displayed, there is nothing more you need to do. After about 3 seconds, the seconds will once again be displayed on your clock.


What does the antenna icon mean on the ACURITE 00592W display?

The antenna icon will flash on and off during synchronization with the radio-controlled clock signal. If the icon disappears, this indicates that the radio signal is not available. If you are unable to obtain a signal after a long period of time, try placing the base unit away from sources of interference such as computers, televisions, cordless phone bases, and other electronic items.

Note: The synchronization process can take 24-72 hours.


How do I switch between Celsius and Fahrenheit on the ACURITE 00592W?

Press and release the “-” (minus) C/F button on the main unit. A beep sounds, and the display will change to either Fahrenheit or Celsius.


What do the trend indicator arrows mean on the ACURITE 00592W?

Arrow icons in the upper display will indicate the following trends for temperature and humidity:

Rising: An upward-pointing arrow.

Steady: A horizontal arrow.

Falling: A downward-pointing arrow.

The arrow icons will indicate rising, steady or falling if the temperature or humidity change is more than 1 unit (degree/percent) within an hour.


How do I set the alarm on the ACURITE 00592W?

1) Hold “ALARM” for 3 seconds.

2) The hour number(s) flash. Press “+” or “-” to enter the desired hour. Press “ALARM” to confirm the hour setting.

3) The minute number(s) flash. Press “+” or “-” to enter the desired minute. Press “ALARM” to confirm the minute setting.

To view the alarm time, press the “ALARM” button during the normal operating mode. Alarm time will display for five seconds.


How do I turn the alarm on and off on the ACURITE 00592W?

To Turn the Alarm On and Off: Press the “+” button during the normal operating mode.

To Turn off the Alarm for One Day: To turn the alarm off for one day, press the “ALARM” button when the alarm sounds.


How does the Snooze/Light function work on the ACURITE 00592W?

When the alarm sounds, press the “SNOOZE/LIGHT” button to trigger the snooze feature. The alarm is silenced for five minutes, then it will sound an alarm again. The “SNOOZE/LIGHT” button also activates the built-in backlight for 5 seconds.


How do I use the MIN/MAX memory feature on the ACURITE 00592W?

Press the “MEMORY” button to view the maximum values (Inside/Outside Temperature and Humidity) for 5 seconds. Press the “MEMORY” button again to view the minimum memory.

The memory will automatically refresh every 24 hours.


How can I set up multiple wireless sensors with my ACURITE 00592W?

The main unit supports up to three wireless sensors. Each additional wireless sensor must be designated a different channel number. To add another sensor:

1) Open each sensor by separating the front and back case.

2) Install batteries, as per the battery installation instructions.

3) Use the interior slide switch to select a channel – 1, 2, or 3.

4) Choose Celsius or Fahrenheit with the C/F button, for the sensor display.

5) With the “MODE” button choose what you want the sensor display to show: Temperature only, Humidity only, or Temperature and humidity, alternating.

6) Press the “TX” button to send a signal to the base station.

7) Snap the two halves of the case together firmly.

8) Mount the sensor, following the placement guidelines.


What are the product specifications for the ACURITE 00592W?

MEASUREMENT RANGE:

Indoor main unit: 0° C to + 50° C (+32° F to +122° F)

Outdoor/Indoor humidity: 20% – 99% RH

Wireless sensor: -20° C to +70° C (-4° F to +158° F)

Channel: maximum of three wireless sensors

Transmission: up to 30M (100 ft.) open area, RF 33MHz

Resolution: 0.1° for temperature, 1% for humidity

Clock: WWVB radio-controlled, quartz back-up

Batteries: AA x 2 alkaline for main unit; AA x 2 alkaline for wireless sensor