3M 8300 (01) PDF MANUAL


Post questions, comments, reviews or errors in the comment box below.

Your File is Ready … Download PDF

CLICK HERE TO DOWNLOAD 3M 8300 (01) PDF MANUAL


PDF Content Summary: 3M Occupational Health & Environmental Safety Group 3M 8300 Series Comfort Respirators Respirator Type APF VALVE 8310 FFP1 NR D 4 8312 FFP1 NR D 4 FFP2 NR D 10 8322 FFP2 NR D 10 / 8833 FFP3 R D 20 / Standard: EN149:2001 + A1:2009 This respirator should not be used in oxygen deficient environments, for escape purposes or by people with beards/ facial hair or in atmospheres where concentrations of contaminant may exceed that deemed Immediately Dangerous to Life and Health (IDLH). Occupational Health & Environmental Safety Group 3M United Kingdom plc 3M Centre, Cain Road, Bracknell Berkshire RG12 8HT Tel: 0870 60 800 60 3M.co.uk/ohes / 8320 3M Ireland Limited The Iveagh Building The Park Carrickmines Dublin 18 Tel: 1 800 320 500 Please recycle. Printed in UK. © 3M 2009. All rights reserved. 3MTM 8300 Series Comfort Respirators Fitting Instructions CH8300FP V2 1 3 1. Cup the respirator in your hand with the nosepiece at your fingertips allowing the headbands to hang freely below your hand. 2. Position the respirator under your chin with the nosepiece up. 3. Pull the top strap over your head resting it high at the top back of your head. Pull the bottom strap over your head and position it around the neck below the ears. Make sure that the straps are not twisted. 4. Place the fingertips of both hands at the top of the metal nosepiece. Mould the nosepiece to the shape of your nose by pushing inward while moving your fingertips down both sides of the nosepiece. Pinching the nosepiece using one hand may result in less effective respirator performance. 5. The seal of the respirator on the face should be fit checked prior to wearing in the work area. Fit Testing: The 3M 8300 Series Respirator is a tight fitting facepiece and therefore wearers require a fit test as per the COSHH regulations 2002. For qualitative testing - 3MTM FT10 and FT30 Fit Test Kits are available. 2 Fit Check Procedure For Valved Respirators: a) Cover the front of the respirator with both hands, being careful not to disturb the position of the respirator. b) Inhale sharply. A negative pressure should be felt inside the respirator. If air leaks around the nose, readjust the noseclip as described in step 4 to eliminate leakage. Repeat the above fit check. If air leaks at the respirator edges, work the straps back along the sides of the head to eliminate leakage. Retest the seal. Repeat the procedure until the respirator fits properly. For Unvalved Respirators: a) Cover the front of the respirator with both hands, being careful not to disturb the position of the respirator. b) Exhale sharply. A positive pressure should be felt inside the respirator. If air leaks around the nose, readjust the noseclip as described in step 4 to eliminate leakage. Repeat the above fit check. If air leaks at the respirator edges, work the straps back along the sides of the head to eliminate leakage. Retest the seal. Repeat the procedure until the respirator fits properly. If you cannot achieve a proper fit, do not enter the contaminated area. See your supervisor. Note: Do not use with beards or other facial hair that may inhibit contact between the face and the edge of the respirator. 44 55


FREE ENGLISH PDF

OPERATING INSTRUCTIONS

USER GUIDE - USER MANUAL

OWNER GUIDE - OWNER MANUAL

REFERENCE GUIDE - REFERENCE MANUAL

INSTRUCTION GUIDE - INSTRUCTION MANUAL

Leave a Reply